111 research outputs found

    Current Status and Future Prospects of Proton MR Spectroscopy of the Breast with a 1.5T MR Unit

    Get PDF
    Proton MR spectroscopy of the mammary gland area is used to be considered in the realm of basic research, but as a result of the advances in MR techniques, it is now being performed in ordinary clinical practice. It is particularly noteworthy that useful clinical data are now being accumulated with 1.5T MR units, which are the standard units. We think that, at this point, it is very important to systematically review the techniques, clinical applications, and future prospects of proton MR spectroscopy. We have performed proton MR spectroscopy with a 1.5T MR unit in over 3000 cases at our hospital. In this paper, we will comment on the current status of proton MR spectroscopy of the breast, primarily in regard to differentiation between benign and malignant lesions and prediction of the efficacy of chemotherapy while describing the data obtained at our hospital

    Giant Hysteretic Single‐Molecule Electric Polarisation Switching above Room Temperature

    Get PDF
    Continual progress has been achieved in information technology through unrelenting miniaturisation of the single memory bit in integrated ferromagnetic, ferroelectric, optical, and related circuits. However, as miniaturisation approaches its theoretical limit, new memory materials are being sought. Herein, we report a unique material exhibiting single‐molecule electric polarisation switching that can operate above room temperature. The phenomenon occurs in a Preyssler‐type polyoxometalate (POM) cluster we call a single‐molecule electret (SME). It exhibits all the characteristics of ferroelectricity but without long‐range dipole ordering. The SME affords bi‐stability as a result of the two potential positions of localisation of a Tb3+ ion trapped in the POM, resulting in extremely slow relaxation of the polarisation and electric hysteresis with high spontaneous polarisation and coercive electric fields. Our findings suggest that SMEs can potentially be applied to ultrahigh‐density memory and other molecular‐level electronic devices operating above room temperature.This study was supported by JSPS KAKENHI Grant Numbers JP16H04223, JP16K14101, JP24350095, and JP25220803;the Joint Research Project between JSPS and the National Science Foundation of China (NSFC);and JSPS Core-to-Core Program, A. Advanced Research Networks. This work was also performed under the aegis of the Canon Science Promotion Foundation, Murata Science Foundation, Casio Science Promotion Foundation, and the Cooperative Research Program of “Network Joint Research Centre for Materials and Devices”. M.K. is also funded by CNRS, France.アクセプト後にキーワード・アブストラクト等変更あり

    Advantages of radial volumetric breath-hold examination (VIBE) with k-space weighted image contrast reconstruction (KWIC) over Cartesian VIBE in liver imaging of volunteers simulating inadequate or no breath-holding ability

    Get PDF
    To investigate the superiority of radial volumetric breath-hold examination (r-VIBE) with k-space weighted image contrast reconstruction (KWIC) over Cartesian VIBE (c-VIBE) for reducing motion artefacts. We acquired r-VIBE-KWIC and c-VIBE images in 10 healthy volunteers. Each acquisition lasted 24 seconds. The volunteers held their breath for decreasing lengths of time during the acquisitions, from 24 to 0 seconds (protocols A-E). Magnetic resonance images at the level of the right portal vein and confluence of hepatic veins were assessed by two readers using a five-point scale with a higher number indicating a better study. The mean scores for the complete r-VIBE-KWIC series (r-VIBEfull) and first r-VIBE-KWIC series (r-VIBE1) were not significantly lower than those for c-VIBE in any protocols. The mean scores for c-VIBE were lower than those for r-VIBEfull and r-VIBE1 in protocols C and D. The mean score for c-VIBE was lower than that for r-VIBEfull in protocol E. The mean score for the eighth r-VIBE-KWIC series (r-VIBE8) was lower than that for c-VIBE only in protocol B. r-VIBE-KWIC minimised artefacts relative to c-VIBE at any slice location. The r-VIBE-KWIC's sub-frame images during the breath-holding period were hardly affected by another failed breath-holding period. aEuro cent A two-reader study revealed r-VIBE-KWIC's advantages over c-VIBE aEuro cent The image quality of r-VIBE-KWIC's sub-frame images was maintained during breath holding aEuro cent Full-frame r-VIBE-KWIC images minimized motion artefacts caused by breathing aEuro cent A complete breath holding over half the acquisition time is recommended for c-VIBE aEuro cent c-VIBE was susceptible to respiratory motion especially in the subphrenic region.ArticleEUROPEAN RADIOLOGY.26(8):2790-2797(2016)journal articl

    Evaluation of hemodynamic imaging findings of hypervascular hepatocellular carcinoma: comparison between dynamic contrast-enhanced magnetic resonance imaging using radial volumetric imaging breath-hold examination with k-space-weighted image contrast reconstruction and dynamic computed tomography during hepatic arteriography

    Get PDF
    To compare the visualization of hemodynamic imaging findings of hypervascular hepatocellular carcinoma (HCC) on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using radial volumetric imaging breath-hold examination with k-space-weighted image contrast reconstruction (r-VIBE-KWIC) versus dynamic computed tomography during hepatic arteriography (dyn-CTHA). We retrospectively reviewed the databases of preoperative DCE-MRI using r-VIBE-KWIC, dyn-CTHA, and postoperative pathology of resected specimens. Fourteen patients with 14 hypervascular HCCs underwent both DCE-MRI and dyn-CTHA. The imaging findings of the tumor and adjacent liver parenchyma were assessed on both modalities by two readers. The tumor enhancement time was also compared between the two modalities. On DCE-MRI/dyn-CTHA, early staining, peritumoral low-intensity or low-density bands, corona enhancement, and washout of HCC were observed in 14/14 (100%), 10/12 (83%), 11/14 (78%), and 4/14 (29%) patients, respectively. Pathologically, four HCCs with low-density bands on dyn-CTHA had no fibrous capsules. The median tumor enhancement time on DCE-MRI and dyn-CTHA was 24 (9-24) and 23 (8-35) s, respectively. The correlation coefficient between the two groups was 0.762 (P < 0.002). DCE-MRI using r-VIBE-KWIC has diagnostic potential comparable with that of dyn-CTHA in the hemodynamic evaluation of hypervascular HCC except for the washout phenomenon.ArticleJAPANESE JOURNAL OF RADIOLOGY.36(4):295-302(2018)journal articl

    Radial volumetric imaging breath-hold examination (VIBE) with k-space weighted image contrast (KWIC) for dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced MRI of the liver: advantages over Cartesian VIBE in the arterial phase

    Get PDF
    To compare radial volumetric imaging breath-hold examination with k-space weighted image contrast reconstruction (r-VIBE-KWIC) to Cartesian VIBE (c-VIBE) in arterial phase dynamic gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (DCE-MRI) of the liver. We reviewed 53 consecutive DCE-MRI studies performed on a 3-T unit using c-VIBE and 53 consecutive cases performed using r-VIBE-KWIC with full-frame image subset (r-VIBEfull) and sub-frame image subsets (r-VIBEsub; temporal resolution, 2.5-3 s). All arterial phase images were scored by two readers on: (1) contrast-enhancement ratio (CER) in the abdominal aorta; (2) scan timing; (3) artefacts; (4) visualisation of the common, right, and left hepatic arteries. Mean abdominal aortic CERs for c-VIBE, r-VIBEfull, and r-VIBEsub were 3.2, 4.3 and 6.5, respectively. There were significant differences between each group (P < 0.0001). The mean score for c-VIBE was significantly lower than that for r-VIBEfull and r-VIBEsub in all factors except for visualisation of the common hepatic artery (P < 0.05). The mean score of all factors except for scan timing for r-VIBEsub was not significantly different from that for r-VIBEfull. Radial VIBE-KWIC provides higher image quality than c-VIBE, and r-VIBEsub features high temporal resolution without image degradation in arterial phase DCE-MRI. aEuro cent Radial VIBE-KWIC minimised artefact and produced high-quality and high-temporal-resolution images. aEuro cent Maximum abdominal aortic enhancement was observed on sub-frame images of r-VIBE-KWIC. aEuro cent Using r-VIBE-KWIC, optimal arterial phase images were obtained in over 90 %. aEuro cent Using r-VIBE-KWIC, visualisation of the hepatic arteries was improved. aEuro cent A two-reader study revealed r-VIBE-KWIC's advantages over Cartesian VIBE.ArticleEUROPEAN RADIOLOGY. 24(6):1290-1299 (2014)journal articl

    Prediction Models for BMI and NAFLD

    Get PDF
    Nonalcoholic fatty liver disease (NAFLD) is closely associated with obesity. Disulfide bond‐forming oxidoreductase A‐like protein (DsbA‐L) is known to be a key molecule in protection against obesity and obesity‐induced inflammation. In the present study, we used a modeling and simulation approach in an attempt to develop body mass index (BMI) and BMI‐based NAFLD prediction models incorporating the DsbA‐L polymorphism to predict the BMI and NAFLD in 341 elderly subjects. A nonlinear mixed‐effect model best represented the sigmoidal relationship between the BMI and the logit function of the probability of NAFLD prevalence. The final models for BMI and NAFLD showed that DsbA‐L rs1917760 polymorphism, age, and gender were associated with the BMI, whereas gender, patatin‐like phospholipase 3 rs738409 polymorphism, HbA1c, and high‐density and low‐density lipoprotein cholesterol levels were associated with the risk of NAFLD. This information may aid in the genetic‐based prevention of obesity and NAFLD in the general elderly population

    Five-year quality of life assessment after carbon ion radiotherapy for prostate cancer

    Get PDF
    The aim of this study was to prospectively assess 5-year health-related quality of life (HRQOL) of patients treated with carbon ion radiotherapy (C-ion RT) for clinically localized prostate cancer. A total of 417 patients received carbon ion radiotherapy at a total dose of 63–66 Gray-equivalents (GyE) in 20 fractions over 5 weeks, and neoadjuvant and adjuvant androgen deprivation therapy (ADT) were administered for intermediate and high-risk patients. A HRQOL assessment was performed at five time points (immediately before the initiation of C-ion RT, immediately after, and at 12, 36 and 60 months after completion of C-ion RT) using Functional Assessment of Cancer Therapy (FACT) questionnaires. FACT-G and FACT-P scores were significantly decreased; however, the absolute change after 60 months was minimal. The transient decreases in the Trial Outcome Index (TOI) score returned to their baseline levels. Use of ADT, presence of adverse events, and biochemical failure were related to lower scores. Scores of subdomains of FACT instruments indicated characteristic changes. The pattern of HRQOL change after C-ion RT was similar to that of other modalities. Further controlled studies focusing on a HRQOL in patients with prostate cancer are warranted
    corecore