71 research outputs found

    Utilization of surveillance after polypectomy in the Medicare population

    Get PDF
    Background: Surveillance in patients with previous polypectomy was underused in the Medicare population in 1994. This study investigates whether expansion of Medicare reimbursement for colonoscopy screening in high-risk individuals has reduced the inappropriate use of surveillance. Methods: We used Kaplan-Meier analysis to estimate time to surveillance and polyp recurrence rates for Medicare beneficiaries with a colonoscopy with polypectomy between 1998 and 2003 who were followed through 2008 for receipt of surveillance colonoscopy. Generalized Estimating Equations were used to estimate risk factors for: 1) failing to undergo surveillance and 2)

    Aminoglycosides for Intra-Abdominal Infection: Equal to the Challenge?

    Get PDF
    Background: Aminoglycosides, combined with antianaerobic agents, have been used widely for the treatment of intra-abdominal infection. However, some prospective randomized controlled trials and other data suggested that aminoglycosides were less efficacious than newer comparators for the treatment of these infections. We therefore performed a meta-analysis of all prospective randomized controlled trials utilizing aminoglycosides to reevaluate the efficacy of these agents for the treatment of intra-abdominal infection. Methods: Published English-language prospective randomized controlled trials comparing aminoglycosides with other agents for treatment of intra-abdominal infection were identified by MEDLINE search. For each study, data were collected regarding the number of patients enrolled and evaluated, their basic demographic characteristics, the sources of the intra-abdominal infections, the number of failures as determined by the study investigators, quality score, and the use of serum drug concentrations to monitor aminoglycoside therapy. These data were combined to calculate odds ratios for risk of therapeutic failure, which were assessed for significance using Chi-square analysis. Results: Forty-seven prospective randomized controlled trials comparing aminoglycosides to other agents were identified. These were published between 1981 and 2000, and included a total of 5,182 evaluable patients. Analysis of all studies combined revealed an odds ratio that slightly, but significantly, favored the comparators. After excluding six trials using comparators that lacked accepted antianaerobic efficacy, the odds ratio more strongly favored comparators. Trials published since 1990 also notably favored comparators. Analyzing results by quality score or the use of aminoglycoside monitoring did not alter these findings. Conclusions: In this meta-analysis, aminoglycosides were less efficacious than newer comparators for the treatment of intra-abdominal infection. Given the well-known toxicities of these agents, we conclude that they should not be used as first-line therapy for these infections

    Improved Survival Associated with Neoadjuvant Chemoradiation in Patients with Clinical Stage IIIA(N2) Non–Small-Cell Lung Cancer

    Get PDF
    IntroductionOptimal management of clinical stage IIIA-N2 non–small-cell lung cancer (NSCLC) is controversial. This study examines whether neoadjuvant chemoradiation plus surgery improves survival rates when compared with other recommended treatment strategies.MethodsAdult patients from the National Cancer Database, with clinical stage IIIA-N2 disease definitively treated between 1998 and 2004 at American College of Surgeons Commission on Cancer accredited facilities, were included in the study. Treatment was defined as neoadjuvant chemoradiation plus either lobectomy (NeoCRT+L) or pneumonectomy (NeoCRT+P), lobectomy plus adjuvant therapy (L+AT), pneumonectomy plus adjuvant therapy (P+AT), and concurrent chemoradiation (CRT). Median follow-up and overall survival (OS) were defined from date of diagnosis to last contact. Five-year OS was estimated using Kaplan–Meier methods. Cox proportional hazard regression was used to estimate hazard ratios and 95% confidence intervals (CIs), adjusting for sociodemographic, clinical, and facility characteristics.ResultsMedian follow-up was 11.8 months for 11,242 eligible patients. Five-year OS was 33.5%, 20.7%, 20.3%, 13.35%, and 10.9% for NeoCRT+L, NeoCRT+P, L+AT, P+AT, and CRT, respectively (p < 0.0001). On multivariable analysis, the estimated hazard ratio was 0.51 (CI: 0.45–0.58) for NeoCRT+L; 0.77 (0.63–0.95) for NeoCRT+P; 0.66 (0.59–0.75) for L+AT; 0.69 (0.54–0.88) for P+AT; and 1.0 (reference) for the CRT group. Comorbidity did not attenuate the relationship between treatment and survival.ConclusionThis large study demonstrates that patients with clinical stage IIIA-N2 NSCLC, who underwent neoadjuvant chemoradiation followed by lobectomy, were associated with an improved survival

    DC readout experiment in Enhanced LIGO

    Get PDF
    The two 4 km long gravitational wave detectors operated by the Laser Interferometer Gravitational-wave Observatory (LIGO) were modified in 2008 to read out the gravitational wave channel using the DC readout form of homodyne detection and to include an optical filter cavity at the output of the detector. As part of the upgrade to Enhanced LIGO, these modifications replaced the radio-frequency (RF) heterodyne system used previously. We describe the motivations for and the implementation of DC readout and the output mode cleaner in Enhanced LIGO. We present characterizations of the system, including measurements and models of the couplings of the noises from the laser source to the gravitational wave readout channel. We show that noise couplings using DC readout are improved over those for RF readout, and we find that the achieved shot-noise-limited sensitivity is consistent with modeled results

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Search for eccentric black hole coalescences during the third observing run of LIGO and Virgo

    Get PDF
    Despite the growing number of confident binary black hole coalescences observed through gravitational waves so far, the astrophysical origin of these binaries remains uncertain. Orbital eccentricity is one of the clearest tracers of binary formation channels. Identifying binary eccentricity, however, remains challenging due to the limited availability of gravitational waveforms that include effects of eccentricity. Here, we present observational results for a waveform-independent search sensitive to eccentric black hole coalescences, covering the third observing run (O3) of the LIGO and Virgo detectors. We identified no new high-significance candidates beyond those that were already identified with searches focusing on quasi-circular binaries. We determine the sensitivity of our search to high-mass (total mass M&gt;70 M⊙) binaries covering eccentricities up to 0.3 at 15 Hz orbital frequency, and use this to compare model predictions to search results. Assuming all detections are indeed quasi-circular, for our fiducial population model, we place an upper limit for the merger rate density of high-mass binaries with eccentricities 0&lt;e≤0.3 at 0.33 Gpc−3 yr−1 at 90\% confidence level

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM
    corecore