488 research outputs found

    Photochemical amplifier based on self-immolative dendritic spacers

    Get PDF
    A self-immolative dendritic structure was synthesized. It is based on phenol derivatives with three hydroxymethyl arms at both ortho and para positions of the core unit, potentially releasing up to 27 leaving groups in a third-generation dendrimer. The triggering event is the photolysis of a photosentive ortho-nitrobenzyl group. In doing so, we expected to transform a weak chemical or photochemical input into a large chemical output, which fulfills the definition of a molecular amplifier. Such dendrimers could find application as an indicator, a drug-delivery vector, or a solubilizing agent. The prepared dendrimer indeed released up to 27 leaving groups upon photolysis at 360 nm

    Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials

    Get PDF
    Aims The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES). Methods and results We pooled individual patient data from three large-scale multicentre randomized clinical trials (ISAR-TEST 3, ISAR-TEST 4, and LEADERS) comparing biodegradable polymer DES with durable polymer SES and assessed clinical outcomes during follow-up through 4 years. The efficacy endpoint of interest was target lesion revascularization and the safety endpoint of interest was definite stent thrombosis. Out of 4062 patients included in the present analysis, 2358 were randomly assigned to treatment with biodegradable polymer DES (sirolimus-eluting, n= 1501; biolimus-eluting, n= 857) and 1704 patients to durable polymer SES. No heterogeneity across the trials was observed in analyses of the primary and secondary endpoints. At 4 years, the risk of target lesion revascularization was significantly lower among patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.82, 95% CI 0.68-0.98, P= 0.029). In addition, the risk of stent thrombosis was significantly reduced with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.56, 95% CI 0.35-0.90, P= 0.015), driven by a lower risk of very late stent thrombosis (hazard ratio 0.22, 95% CI 0.08-0.61, P= 0.004). In keeping with this, in landmark analysis between 1 and 4 years, the incidence of myocardial infarction was lower for patients treated with biodegradable polymer DES vs. durable polymer SES (hazard ratio 0.59, 95% CI 0.73-0.95, P= 0.031). Conclusion Biodegradable polymer DES improve safety and efficacy compared with durable polymer SES during long-term follow-up to 4 year

    Utility of iron biomarkers in differentiating menopausal status: Findings from CoLaus and PREVEND.

    Get PDF
    AIM To examine the association of iron biomarkers with menopausal status and assess whether these biomarkers can help differentiate menopausal status beyond age. METHODS In this cross-sectional study we included 1679 women from the CoLaus and 2133 from the PREVEND cohorts, with CoLaus used as primary cohort and PREVEND for replication. Ferritin, transferrin, iron, and transferrin saturation (TSAT) were used to assess iron status. Hepcidin and soluble transferrin receptor were assessed only in PREVEND. Menopausal status was self-reported and defined as menopausal or non-menopausal. Logistic regressions were used to explore the association of these iron biomarkers with menopause status. Sensitivity, specificity, area under the receiver operating characteristic curves (AUC), positive and negative predictive values as well as cut-off points for the iron biomarkers were calculated. The model with the highest AUC was defined as the best. RESULTS In the CoLaus and PREVEND cohorts, respectively, 513 (30.6 %) and 988 (46.3 %) women were postmenopausal. Ferritin (OR, 2.20; 95 % CI 1.72-2.90), transferrin (OR, 0.03; 95 % CI 0.01-0.10), and TSAT (OR, 1.28; 95 % CI 1.06-1.54) were significantly associated with menopausal status in CoLaus, with the findings replicated in PREVEND. AUC of age alone was 0.971. The best model resulted from combining age, ferritin, and transferrin, with an AUC of 0.976, and sensitivity and specificity of 87.1 % and 96.5 %, respectively. Adding transferrin and ferritin to a model with age improved menopause classification by up to 7.5 %. In PREVEND, a model with age and hepcidin outperformed a model with age, ferritin, and transferrin. CONCLUSION Iron biomarkers were consistently associated with menopausal status in both cohorts, and modestly improved a model with age alone for differentiating menopause status. Our findings on hepcidin need replication

    Report of a European Society of Cardiology-European Association of Percutaneous Cardiovascular Interventions task force on the evaluation of coronary stents in Europe: executive summary

    Get PDF
    The evaluation for European Union market approval of coronary stents falls under the Medical Device Directive that was adopted in 1993. Specific requirements for the assessment of coronary stents are laid out in supplementary advisory documents. In response to a call by the European Commission to make recommendations for a revision of the advisory document on the evaluation of coronary stents (Appendix 1 of MEDDEV 2.7.1), the European Society of Cardiology (ESC) and the European Association of Percutaneous Cardiovascular Interventions (EAPCI) established a Task Force to develop an expert advisory report. As basis for its report, the ESC-EAPCI Task Force reviewed existing processes, established a comprehensive list of all coronary drug-eluting stents that have received a CE mark to date, and undertook a systematic review of the literature of all published randomized clinical trials evaluating clinical and angiographic outcomes of coronary artery stents between 2002 and 2013. Based on these data, the TF provided recommendations to inform a new regulatory process for coronary stents. The main recommendations of the task force include implementation of a standardized non-clinical assessment of stents and a novel clinical evaluation pathway for market approval. The two-stage clinical evaluation plan includes recommendation for an initial pre-market trial with objective performance criteria (OPC) benchmarking using invasive imaging follow-up leading to conditional CE-mark approval and a subsequent mandatory, large-scale randomized trial with clinical endpoint evaluation leading to unconditional CE-mark. The data analysis from the systematic review of the Task Force may provide a basis for determination of OPC for use in future studies. This paper represents an executive summary of the Task Force's repor

    A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials.</p> <p>Methods/Design</p> <p>The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1), single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express<sup>2 </sup>paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to <2.75 mm that compares TAXUS Element with a matched historical bare metal Express stent control.</p> <p>Discussion</p> <p>The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at <url>http://www.clinicaltrials.gov</url>, identification numbers NCT00484315 and NCT00489541.</p

    Rationale and design of the MULTISTARS AMI Trial: a randomized comparison of immediate versus staged complete revascularization in patients with ST-segment elevation myocardial infarction and multivessel disease

    Get PDF
    Background: About half of patients with acute ST-segment elevation myocardial infarction (STEMI) present with multivessel coronary artery disease (MVD). Recent evidence supports complete revascularization in these patients. However, optimal timing of non-culprit lesion revascularization in STEMI patients is unknown because dedicated randomized trials on this topic are lacking. Study design: The MULTISTARS AMI trial is a prospective, international, multicenter, randomized, two-arm, open-label study planning to enroll at least 840 patients. It is designed to investigate whether immediate complete revascularization is non-inferior to staged (within 19-45 days) complete revascularization in patients in stable hemodynamic conditions presenting with STEMI and MVD and undergoing primary percutaneous coronary intervention (PCI). After successful primary PCI of the culprit artery, patients are randomized in a 1:1 ratio to immediate or staged complete revascularization. The primary endpoint is a composite of all-cause death, non-fatal myocardial infarction, ischemia-driven revascularization, hospitalization for heart failure, and stroke at 1 year. Conclusions: The MULTISTARS AMI trial tests the hypothesis that immediate complete revascularization is non-inferior to staged complete revascularization in stable patients with STEMI and MVD

    Revascularisation versus medical treatment in patients with stable coronary artery disease: network meta-analysis.

    Get PDF
    peer reviewedOBJECTIVE: To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. DESIGN: Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. DATA SOURCES: Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. MAIN OUTCOME MEASURE: All cause mortality. RESULTS: 100 trials in 93,553 patients with 262,090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably reduced by coronary artery bypass grafting (0.16, 0.13 to 0.20) followed by new generation drug eluting stents (zotarolimus (Resolute): 0.26, 0.17 to 0.40; everolimus: 0.27, 0.21 to 0.35), early generation drug eluting stents (zotarolimus (Endeavor): 0.37, 0.28 to 0.50; sirolimus: 0.29, 0.24 to 0.36; paclitaxel: 0.44, 0.35 to 0.54), and bare metal stents (0.69, 0.59 to 0.81) compared with medical treatment. CONCLUSION: Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation to a variable degree. Our results provide evidence for improved survival with new generation drug eluting stents but no other percutaneous revascularisation technology compared with medical treatment
    corecore