4 research outputs found

    HIV-1 Effects on Neuropsychological Performance in a Resource-Limited Country, Zambia

    Get PDF
    Zambia has substantially been affected by the HIV/AIDS epidemic with prevalence rates at 14% in a population estimated at 12 million. Yet, the extent of HIV-associated neurocognitive disorders (HAND) in this population remains to be clearly understood. A series of culturally appropriate neuropsychological (NP) assessments [International HIV Dementia Scale (IHDS), Color Trails Test 1 and 2, Grooved pegboard Test, and Time Gait Test] were used to test the effects of HIV on NP performance of HIV seropositive and seronegative individuals. Twenty-two percent HIV positive individuals ARV naïve met the criteria for IHDS-defined NP impairment. Gender significantly influenced the performance on NP tests with females performing more poorly compared to males. Larger studies that will accommodate gender differences and age are necessary to generate appropriate norms in Zambia in order to better assess the prevalence of HAND in the developing country setting

    Verification of dried blood spot as a sample type for HIV viral load and early infant diagnosis on Hologic Panther in Zambia

    No full text
    Abstract Objective Zambia has embarked on improving the diagnostic capacity by setting up high throughput and accurate machines in the testing process and introduction of dried blood spot (DBS) as a sample type. This was a cross sectional study to verify dried blood spot as a sample type for HIV viral load and early infant diagnosis (EID) on Hologic Panther platform and Evaluate the analytical performance (precision, linearity and measurement of uncertainty) of the Hologic Panther. Results The specificity and sensitivity of EID performance of Aptima Quant Dx assay on Hologic panther machine against the gold standard machine COBAS Taqman (CAP/CTM) was 100% with an overall agreement of 100%. The quantitative HIV Viral Load (VL) accuracy had a positive correlation of (0.96) obtained against the gold standard (plasma samples) run on COBAS4800 platform. Analytical performance of the Hologic panther machine was evaluated; Precision low positive repeatability 3.50154 and within lab 2.268915 at mean 2.88 concentration and precision high positive repeatability 1.116955 and within lab 2.010677 at mean 5.09 concentration were obtained confirming manufacturers claims. Uncertainty of measurement for this study was found to be ± 71 copies/ml. Linearity studies were determined and all points were within acceptable limits. We therefore recommend DBS as a sample type alternative to plasma for the estimation of HIV-1 viral load and EID diagnosis on the Hologic panther machine
    corecore