64 research outputs found

    Neuroanatomy of hemispatial neglect and its functional components: a study using voxel-based lesion-symptom mapping

    Get PDF
    Spatial neglect is a perplexing neuropsychological syndrome, in which patients fail to detect (and/or respond to) stimuli located contralaterally to their (most often right) hemispheric lesion. Neglect is characterized by a wide heterogeneity, and a role for multiple components has been suggested, but the exact nature of the critical components remains unclear. Moreover, many different lesion sites have been reported, leading to enduring controversies about the relative contribution of different cortical and/or subcortical brain regions. Here we report a systematic anatomo-functional study of 80 patients with a focal right hemisphere stroke, who were examined by a series of neuropsychological tests assessing different clinical manifestations of neglect. We first performed a statistical factorial analysis of their behavioural performance across all tests, in order to break down neglect symptoms into coherent profiles of co-varying deficits. We then examined the neural correlates of these distinct neglect profiles using a statistical voxel-based lesion-symptom mapping method that correlated the anatomical extent of brain damage with the relative severity of deficits along the different profiles in each patient. Our factorial analysis revealed three main factors explaining 82% of the total variance across all neglect tests, which suggested distinct components related to perceptive/visuo-spatial, exploratory/visuo-motor, and allocentric/object-centred aspects of spatial neglect. Our anatomical voxel-based lesion-symptom mapping analysis pointed to specific neural correlates for each of these components, including the right inferior parietal lobule for the perceptive/visuo-spatial component, the right dorsolateral prefrontal cortex for the exploratory/visuo-motor component, and deep temporal lobe regions for the allocentric/object-centred component. By contrast, standard anatomical overlap analysis indicated that subcortical damage to paraventricular white matter tracts was associated with severe neglect encompassing several tests. Taken together, our results provide new support to the view that the clinical manifestations of hemispatial neglect might reflect a combination of distinct components affecting different domains of spatial cognition, and that intra-hemispheric disconnection due to white matter lesions might produce severe neglect by impacting on more than one functional domai

    Radiologic Patterns of Necrosis After Proton Therapy of Skull Base Tumors

    Get PDF
    Background: Discrimination between radiation necrosis and tumor progression after radiation therapy represents a radiologic challenge. The aim of our investigation is to identify patterns of radiation necrosis on brain magnetic resonance imaging (MRI) and positron emission tomography (PET) with Fluoroethyltyrosin (FET) after proton beam therapy (PBT) for skull base tumors. Material and Methods: Five consecutive patients with extra-axial neoplasms were included, presenting a total of eight radiation necrosis lesions (three clival chordomas; two petroclival chondrosarcomas; two women; mean age: 49 ± 18.2 years). Radiation necrosis was defined as the appearance of abnormal enhancement on MRI after PBT decreasing over time, and additional histopathologic confirmation in one patient. MRI and PET imaging were retrospectively analyzed by two experienced radiologists in consensus. Results: All lesions were localized close to the primary tumor in the field of irradiation. Three patients showed bilateral symmetrical lesions. All lesions showed T2 hyperintensity and T1 hypointensity. Cerebral blood volume (CBV) was reduced in all available studies. None of the lesions showed a restricted diffusion. FET-PET (three patients) showed a higher uptake in four out of five lesions; three of which had a mean tumor-to-background (TBRmean) uptake lower than 1.95 and FET uptake increasing over time and were correctly classified into radiation necrosis. Conclusions: Most radiation necroses were in direct continuity with the primary tumor mimicking tumor progression. The most consistent imaging findings for PBT radiation necrosis are low CBV without restricted diffusion and FET-PET TBRmean lower than 1.95 or increasing uptake over time. Bilateral symmetric involvement may be another indicator of radiation necrosi

    Use of the Enterpriseâ„¢ Intracranial Stent for Revascularization of Large Vessel Occlusions in Acute Stroke

    Get PDF
    Background and Purpose:: Major cerebral thromboembolism often resists recanalization with currently available techniques. The authors present their initial experience with a self-expanding stent for use in intracranial vascular reconstruction, permitting immediate recanalization of acute thromboembolic occlusions of the anterior circulation. Patients and Methods:: Patients treated with the Cordis Enterprise™ self-expanding intracranial stent system for acute thromboembolic occlusion of the major anterior cerebral arteries were included. Treatment comprised systemic and intraarterial thrombolysis, mechanical thrombectomy, and stent placement. Stent deployment, recanalization rate by means of Thrombolysis In Cerebral Infarction (TICI) scores and the clinical outcome were all assessed. Results:: Six patients presenting with acute carotid T (n = 2) or proximal middle cerebral artery occlusion (n = 4) were treated. The mean National Institutes of Health Stroke Scale (NIHSS) score at presentation was 14; the mean age was 57 years. Successful stent deployment and immediate recanalization were achieved in all six with a TICI score of ≥ 2. Neither distal emboli nor any procedure-related complications were encountered. One patient developed symptomatic intracerebral hemorrhage and two patients needed decompressive craniectomy after treatment. The mean NIHSS score at 10 days was 10, but only one patient showed a complete recovery at 3 months. Conclusion:: Intracranial placement of the Enterprise™ self-expanding stent has proven to be feasible and efficient in achieving immediate recanalization of occluded main cerebral arteries. The use of antiplatelet therapy after treatment may, however, increase the risk of reperfusion intracerebral hemorrhag

    Multivariate Pattern Recognition for Diagnosis and Prognosis in Clinical Neuroimaging: State of the Art, Current Challenges and Future Trends

    Get PDF
    Many diseases are associated with systematic modifications in brain morphometry and function. These alterations may be subtle, in particular at early stages of the disease progress, and thus not evident by visual inspection alone. Group-level statistical comparisons have dominated neuroimaging studies for many years, proving fascinating insight into brain regions involved in various diseases. However, such group-level results do not warrant diagnostic value for individual patients. Recently, pattern recognition approaches have led to a fundamental shift in paradigm, bringing multivariate analysis and predictive results, notably for the early diagnosis of individual patients. We review the state-of-the-art fundamentals of pattern recognition including feature selection, cross-validation and classification techniques, as well as limitations including inter-individual variation in normal brain anatomy and neurocognitive reserve. We conclude with the discussion of future trends including multi-modal pattern recognition, multi-center approaches with data-sharing and cloud-computing

    3D fat-saturated T1 SPACE sequence for the diagnosis of cervical artery dissection

    Get PDF
    Introduction: This study aims to demonstrate the added value of a 3D fat-saturated (FS) T1 sampling perfection with application-optimised contrast using different flip angle evolutions (SPACE) sequence compared to 2D FS T1 spin echo (SE) for the diagnosis of cervical artery dissection. Methods: Thirty-one patients were prospectively evaluated on a 1.5-T MR system for a clinical suspicion of acute or subacute cervical artery dissection with 3D T1 SPACE sequence. In 23 cases, the axial 2D FS T1 SE sequence was also used; only these cases were subsequently analysed. Two neuroradiologists independently and blindly assessed the 2D and 3D T1 sequences. The presence of recent dissection (defined as a T1 hyperintensity in the vessel wall) and the quality of fat suppression were assessed. The final diagnosis was established in consensus, after reviewing all the imaging and clinical data. Results: Overall sensitivity and specificity were 0.929 and 1 for axial T1 SE, and 0.965 and 0.945 for T1 SPACE (P > 0.05), respectively. The two readers had excellent agreement for both sequences (k = 1 and 0.8175 for T1 SE and T1 SPACE, respectively; P > 0.05). The quality of the fat saturation was similar. Very good fat saturation was obtained in the upper neck. Multiplanar reconstructions were very useful in tortuous regions, such as the atlas loop of the vertebral artery or the carotid petrous entry. 3D T1 SPACE sequence has a shorter acquisition time (3min 25s versus 5min 32s for one T1 SE sequence) and a larger coverage area. Conclusion: 3D T1 SPACE sequence offers similar information with its 2D counterpart, in a shorter acquisition time and larger coverage are

    Preoperative transarterial embolization of vertebral metastases

    Get PDF
    The aim of this study was to evaluate the impact of preoperative devascularization of spinal metastases in relation to the preembolization tumor vascularization degree and in relation to the intraoperative blood loss. Twenty-four patients underwent preoperative transarterial embolization of hypervascular spinal metastases. Each tumor was assigned a vascularization grade (I-III) according to tumor blush after contrast agent injection in the main feeding artery. Embolization was performed with polyvinyl alcohol particles in all patients. Surgical reports were reviewed in terms of estimated blood loss. A mild hypervascularization was found in three patients (group I), medium in six patients (group II) and extensive in 15 patients (group III). In 22 out of 24 patients embolization could be performed with a complete devascularization. In two patients, only partial embolization could be performed, due to the main feeding artery arising from the artery of Adamkiewicz. In patients with complete devascularization the mean intraoperative blood loss was 1,900ml, whereas in the two patients who were not embolized it was 5,500ml. Intraoperative blood loss was not correlated to the vascularization grade. Angiography and embolization could be performed in all patients without causing permanent neurologic deficit, skin or muscle necrosis. The surgeons concluded that radical tumor resection after embolization was facilitated. Intraoperative blood loss is not correlated with the pre-interventional vascularization degree, if complete devascularization can be achieved with embolization. Preoperative embolization of vertebral hypervascular tumors is safe, effective and facilitates tumor resectio

    Functional imaging of head and neck squamous cell carcinoma with diffusion-weighted MRI and FDG PET/CT: quantitative analysis of ADC and SUV

    Get PDF
    Purpose: Head and neck squamous cell carcinoma (HNSCC) may cause a decreased apparent diffusion coefficient (ADC) on diffusion-weighted magnetic resonance imaging (DW MRI) and an increased standardized uptake value (SUV) on fluorodeoxyglucose (FDG) positron emission tomography (PET/CT). We analysed the reproducibility of ADC and SUV measurements in HNSCC and evaluated whether these biomarkers are correlated or independent. Methods: This retrospective analysis of DW MRI and FDG PET/CT data series included 34 HNSCC in 33 consecutive patients. Two experienced readers measured tumour ADC and SUV values independently. Statistical comparison and correlation with histopathology was done. Intra- and inter-observer agreement for ADC and SUV measurements was assessed. Results: Intraclass correlation coefficient (ICC) analysis showed almost perfect reproducibility (>0.90) for ADCmean, ADCmin, SUVmax and SUVmean values for intra-observer and inter-observer agreement. Mean ADCmean and ADCmin in HNSCC were 1.05 ± 0.34 × 10−3 mm2/s and 0.65 ± 0.29 × 10−3 mm2/s, respectively. Mean SUVmean and mean SUVmax were 7.61 ± 3.87 and 12.8 ± 5.0, respectively. Although statistically not significant, a trend towards higher SUV and lower ADC was observed with increasing tumour dedifferentiation. Pearson's correlation analysis showed no significant correlation between ADC and SUV measurements (r −0.103, −0.051; p 0.552, 0.777). Conclusion: Our data suggest that ADC and SUV values are reproducible and independent biomarkers in HNSC

    In vitro evaluation of how the presence of the stent retriever and microcatheter influences aspiration parameters in thrombectomy according to their position inside the aspiration catheter

    Full text link
    BACKGROUND Several variations of the combined thrombectomy technique for acute ischemic stroke using a stent retriever and aspiration catheter have been described. The aim of our study was to assess how the presence of the microcatheter and stent retriever affect the basic aspiration parameters, namely, flow rate and aspiration force, depending on their position within the aspiration catheter. METHODS Two experimental set-ups were designed to assess changes in flow rate and aspiration force according to the position of the stent retriever and microcatheter within the aspiration catheter. RESULTS The transition of the stent retriever and microcatheter from the distal to proximal position resulted in a progressive increase in the flow rate, but with no impact on aspiration force. Additionally, the size of the stent retriever had no significant effect on flow rate changes and the reduction in flow rate was related to the microcatheter diameter. Negative pressure generated inside the aspiration catheter impacted on its distal segment located beyond the radiopaque marker, thus leading to its partial collapse. As a consequence, the measured aspiration force was lower than the theoretical aspiration force level for all tested aspiration catheters. CONCLUSIONS In our experimental model, the position of the stent retriever and microcatheter within the aspirator catheter affected the flow rate, but not the aspiration force. Negative pressure generated within the aspiration catheter appeared to determine a partial collapse of the distal segment that resulted in a less effective aspiration force than the theoretical aspiration force level
    • …
    corecore