15 research outputs found

    Process stratigraphy: from numerical simulation to lithology prediction

    No full text
    Process-based stratigraphic models provide attractive tools to simulate sedimentary system dynamics spanning a wide range of spatial and temporal scales and segments of the sediment routing system while allowing full access to the model responses, i.e. the spatial distribution of lithologies as a function of the intervening processes and environmental conditions at the time of deposition. Apart from improving our understanding regarding the evolution of sedimentary systems under pre-specified allogenic forcing mechanisms and intrinsic dynamics, process-based stratigraphic models can be used to improve basin-fill history reconstructions and increase the geological credibility of static reservoir models by integrating regional information to local-scale heterogeneities. The realism and predictive power of the model responses and geological model realizations may be quantitatively assessed by comparison with the geophysical/geological data available.Hydraulic Structures and Flood RiskApplied Geolog

    Evaluation of contrast sensitivity in visually impaired individuals using K-CS test. A novel smartphone-based contrast sensitivity test-Design and validation.

    No full text
    BackgroundTo describe the development and investigate the accuracy of a novel smartphone-based Contrast Sensitivity (CS) application, the K-CS test.MethodsA total of 67 visually impaired and 50 normal participants were examined monocularly using the novel digital K-CS test and the Pelli-Robson (PR) chart. The K-CS test examines letter contrast sensitivity in logarithmic units, using eight levels of contrast from logCS = ~0,1 to logCS = ~2,1 at two spatial frequencies of 1.5 and 3 cycles per degree (cpd). The K-CS test was compared to the gold standard, PR test and intra-session test repeatability was also examined.ResultsThe K-CS test in normally sighted was found to agree well with the PR, providing comparable mean scores in logCS (±SD) (K-CS = 1.908 ± 0.06 versus PR = 1.93 ± 0.05) at 1.5 cpd and mean (± SD) logCS at 3 cpd (K-CS = 1.83 ± 0.13 versus PR = 1.86 ± 0.07). The mean best corrected visual acuity of visually impaired participants was 0.67 LogMAR (SD = 0.21) and the K-CS was also found to agree well with the Pelli-Robson in this group, with an equivalent mean (±SD) logCS at 1.5 cpd: (K-CS = 1.19 ± 0.27, PR = 1.15 ± 0.31), 3 cpd: K-CS = 1.01 ± 0.33, PR = 0.94 ± 0.34. Regarding the intra-session test repeatability, both the K-CS test and the PR test showed good repeatability in terms of the 95% limits of agreement (LoA): K-CS = ±0.112 at 1.5 cpd and ±0.133 at 3 cpd, PR = ±0.143 at 1.5 cpd and ±0.183 in 3 cpd in visually impaired individuals.ConclusionThe K-CS test provides a quick assessment of the CS both in normally sighted and visually impaired individuals. The K-CS could serve as an alternative tool to assess contrast sensitivity function using a smartphone and provides results that agree well with the commonly used PR test

    Improved subsurface property prediction in the Netherlands by integrating stratigraphic forward modelling

    No full text
    Classic geological reservoir characterisation relies on interpolation of high resolution well data with (at best) low resolution seismic derived data. In order to fill the data gap (e.g. in labyrinthine type fluvial deposits) we present a methodology to integrate basin scale information in reservoir scale static models by calibrating output from a Stratigraphic Forward Model (SFM). This project showcases the applicability of the integrated workflow to improve facies and property prediction at different scales. By calibrating the parameterized data from the SFM to independent constraints such as thicknesses from seismic interpretations and well logs the model greatly improve property prediction. Previous studies showed the application to synthetic datasets, this study aims to apply the methodology to the Holocene Rhine-Meuse fluvial deposits in the shallow subsurface of the Netherlands. The extraordinary level of detail in the model of these deposits and the parameterized fluvial sedimentation routine in the SFM used provide an ideal test case for the workflow proposed. The ultimate application of the workflow is intended to improve the geological and property models at greater depth where data coverage is limited. © 2016, European Association of Geoscientists and Engineers, EAGE. All rights reserved

    Dryland avulsion sequences: Insights from data-model comparison of a terminal dryland river system

    No full text
    An advection–diffusion model of fluvial processes was used to analyze the stratigraphic expression of avulsions in terminal river systems and understand their control on basin-fill architecture. The initial and boundary conditions of the model runs (i.e., catchment area, smoothed initial topographic surface, grain-size distribution and sediment supply rates) were extracted from the modern Rio Colorado dryland terminal river system in the Altiplano Basin (Bolivia). Water-discharge and sediment-load values were derived from global regression curves and the BQART equation, respectively. To evaluate the robustness of the simulations, the model was tested under increasing sediment-load scenarios ranging from 0.003 m3/s to 0.095 m3/s. Data-model comparison provided insights into the role of avulsions in the geomorphological evolution of terminal river systems. The observed stacking of sediments, as captured by geospatial and geochronological data from the Rio Colorado, is consistent with the high sediment-load scenarios, which start with a single-thread fluvial channel that in time radially expands over the floodplain by successive river avulsions on account of alluvial-ridge aggradation and channel-floor elevation above the surrounding floodplain. The model output shows a laterally extensive, convex-upwards lobate topography which is in agreement with the lateral and longitudinal geomorphology in the upper and lower coastal plain of the Rio Colorado. The simulated inter-avulsion period, which is the time period between two successive full (or stabilized) avulsions in the model, varies from 0.18 to 1.2 kyr and is consistent with the OSL-age determination in the Rio Colorado with inter-avulsion periods up to 1.28 ± 0.34 kyr.Hydraulic Structures and Flood RiskApplied Geolog

    Bland-Altman plot for the differences between the K-CS and PR scores for 1.5 cpd.

    No full text
    The dotted and dashed lines show the mean difference (gray) and the 95% LoA (black) for the low-vision and normally sighted subjects, respectively.</p

    Participant characteristics.

    No full text
    BackgroundTo describe the development and investigate the accuracy of a novel smartphone-based Contrast Sensitivity (CS) application, the K-CS test.MethodsA total of 67 visually impaired and 50 normal participants were examined monocularly using the novel digital K-CS test and the Pelli-Robson (PR) chart. The K-CS test examines letter contrast sensitivity in logarithmic units, using eight levels of contrast from logCS = ~0,1 to logCS = ~2,1 at two spatial frequencies of 1.5 and 3 cycles per degree (cpd). The K-CS test was compared to the gold standard, PR test and intra-session test repeatability was also examined.ResultsThe K-CS test in normally sighted was found to agree well with the PR, providing comparable mean scores in logCS (±SD) (K-CS = 1.908 ± 0.06 versus PR = 1.93 ± 0.05) at 1.5 cpd and mean (± SD) logCS at 3 cpd (K-CS = 1.83 ± 0.13 versus PR = 1.86 ± 0.07). The mean best corrected visual acuity of visually impaired participants was 0.67 LogMAR (SD = 0.21) and the K-CS was also found to agree well with the Pelli-Robson in this group, with an equivalent mean (±SD) logCS at 1.5 cpd: (K-CS = 1.19 ± 0.27, PR = 1.15 ± 0.31), 3 cpd: K-CS = 1.01 ± 0.33, PR = 0.94 ± 0.34. Regarding the intra-session test repeatability, both the K-CS test and the PR test showed good repeatability in terms of the 95% limits of agreement (LoA): K-CS = ±0.112 at 1.5 cpd and ±0.133 at 3 cpd, PR = ±0.143 at 1.5 cpd and ±0.183 in 3 cpd in visually impaired individuals.ConclusionThe K-CS test provides a quick assessment of the CS both in normally sighted and visually impaired individuals. The K-CS could serve as an alternative tool to assess contrast sensitivity function using a smartphone and provides results that agree well with the commonly used PR test.</div

    S1 Data -

    No full text
    BackgroundTo describe the development and investigate the accuracy of a novel smartphone-based Contrast Sensitivity (CS) application, the K-CS test.MethodsA total of 67 visually impaired and 50 normal participants were examined monocularly using the novel digital K-CS test and the Pelli-Robson (PR) chart. The K-CS test examines letter contrast sensitivity in logarithmic units, using eight levels of contrast from logCS = ~0,1 to logCS = ~2,1 at two spatial frequencies of 1.5 and 3 cycles per degree (cpd). The K-CS test was compared to the gold standard, PR test and intra-session test repeatability was also examined.ResultsThe K-CS test in normally sighted was found to agree well with the PR, providing comparable mean scores in logCS (±SD) (K-CS = 1.908 ± 0.06 versus PR = 1.93 ± 0.05) at 1.5 cpd and mean (± SD) logCS at 3 cpd (K-CS = 1.83 ± 0.13 versus PR = 1.86 ± 0.07). The mean best corrected visual acuity of visually impaired participants was 0.67 LogMAR (SD = 0.21) and the K-CS was also found to agree well with the Pelli-Robson in this group, with an equivalent mean (±SD) logCS at 1.5 cpd: (K-CS = 1.19 ± 0.27, PR = 1.15 ± 0.31), 3 cpd: K-CS = 1.01 ± 0.33, PR = 0.94 ± 0.34. Regarding the intra-session test repeatability, both the K-CS test and the PR test showed good repeatability in terms of the 95% limits of agreement (LoA): K-CS = ±0.112 at 1.5 cpd and ±0.133 at 3 cpd, PR = ±0.143 at 1.5 cpd and ±0.183 in 3 cpd in visually impaired individuals.ConclusionThe K-CS test provides a quick assessment of the CS both in normally sighted and visually impaired individuals. The K-CS could serve as an alternative tool to assess contrast sensitivity function using a smartphone and provides results that agree well with the commonly used PR test.</div

    K-CS test.

    No full text
    BackgroundTo describe the development and investigate the accuracy of a novel smartphone-based Contrast Sensitivity (CS) application, the K-CS test.MethodsA total of 67 visually impaired and 50 normal participants were examined monocularly using the novel digital K-CS test and the Pelli-Robson (PR) chart. The K-CS test examines letter contrast sensitivity in logarithmic units, using eight levels of contrast from logCS = ~0,1 to logCS = ~2,1 at two spatial frequencies of 1.5 and 3 cycles per degree (cpd). The K-CS test was compared to the gold standard, PR test and intra-session test repeatability was also examined.ResultsThe K-CS test in normally sighted was found to agree well with the PR, providing comparable mean scores in logCS (±SD) (K-CS = 1.908 ± 0.06 versus PR = 1.93 ± 0.05) at 1.5 cpd and mean (± SD) logCS at 3 cpd (K-CS = 1.83 ± 0.13 versus PR = 1.86 ± 0.07). The mean best corrected visual acuity of visually impaired participants was 0.67 LogMAR (SD = 0.21) and the K-CS was also found to agree well with the Pelli-Robson in this group, with an equivalent mean (±SD) logCS at 1.5 cpd: (K-CS = 1.19 ± 0.27, PR = 1.15 ± 0.31), 3 cpd: K-CS = 1.01 ± 0.33, PR = 0.94 ± 0.34. Regarding the intra-session test repeatability, both the K-CS test and the PR test showed good repeatability in terms of the 95% limits of agreement (LoA): K-CS = ±0.112 at 1.5 cpd and ±0.133 at 3 cpd, PR = ±0.143 at 1.5 cpd and ±0.183 in 3 cpd in visually impaired individuals.ConclusionThe K-CS test provides a quick assessment of the CS both in normally sighted and visually impaired individuals. The K-CS could serve as an alternative tool to assess contrast sensitivity function using a smartphone and provides results that agree well with the commonly used PR test.</div
    corecore