314 research outputs found

    The dynamical playground of a higher-order cubic Ginzburg-Landau equation: from orbital connections and limit cycles to invariant tori and the onset of chaos

    Full text link
    The dynamical behavior of a higher-order cubic Ginzburg-Landau equation is found to include a wide range of scenarios due to the interplay of higher-order physically relevant terms. We find that the competition between the third-order dispersion and stimulated Raman scattering effects, gives rise to rich dynamics: this extends from Poincar\'{e}-Bendixson--type scenarios, in the sense that bounded solutions may converge either to distinct equilibria via orbital connections, or space-time periodic solutions, to the emergence of almost periodic and chaotic behavior. One of our main results is that the third-order dispersion has a dominant role in the development of such complex dynamics, since it can be chiefly responsible (i.e., even in the absence of the other higher-order effects) for the existence of the periodic, quasi-periodic and chaotic spatiotemporal structures. Suitable low-dimensional phase space diagnostics are devised and used to illustrate the different possibilities and identify their respective parametric intervals over multiple parameters of the model.Comment: 11 pages, 9 figures. To appear in Physical Review

    Do physical diagnostic tests accurately detect meniscal tears?

    Full text link

    Epidural bleeding after ACL reconstruction under regional anaesthesia: a case report

    Get PDF
    Introduction: Epidural bleeding as a complication of catheterization or epidural catheter removal is often associated with perioperative thromboprophylaxis especially in adult reconstructive surgery. Case presentation: We report on a case of a 19 years old male athlete that underwent anterior cruciate ligament reconstruction, receiving low molecular weight heparin for thromboprophylaxis and developed an epidural hematoma and subsequent cauda equina syndrome two days after removal of the epidural catheter. An urgent magnetic resonance imaging scan revealed an epidural hematoma from the level of L3 to L4. Emergent decompression and hematoma evacuation resulted in patient's significant neurological improvement immediately postoperatively. Conclusion: A high index of clinical suspicion and surgical intervention are necessary to prevent such potentially disabling complications especially after procedures on a day-case basis and early patient's discharge. © 2009 Roidis et al; licensee Cases Network Ltd

    Practicalities of BVID detection on aerospace-grade CFRP materials with optical fibre sensors

    Get PDF
    Several reports have recently shown the capability of optical fibre sensors for the detection of barely visible impact damage (BVID) on CFRP laminates, based on changes in the optical signal before and after impact. Although this approach was shown to work well in lab conditions, little attention has been paid so far to its practicality when considering realistic ambient conditions or to the detection range. In this work we attempt to derive BVID detection thresholds for fibre Bragg grating-based sensors, by considering standardized temperature and vibration levels for aerospace applications. To the best of our knowledge this is the first practical threshold assessment for BVID detection on aerospace-grade CFRP for such sensors. We have put our detection thresholds to the test by analysing a total of 24 BVIDs on 12 panels made from 4 different CFRP material systems and derived commendable sizes for the detection range on the different material systems

    Resuming elective hip and knee arthroplasty after the first phase of the SARS-CoV-2 pandemic: the European Hip Society and European Knee Associates recommendations

    Full text link
    The Covid-19 pandemic has disrupted health care systems all over the world. Elective surgical procedures have been postponed and/or cancelled. Consensus is, therefore, required related to the factors that need to be in place before elective surgery, including hip and knee replacement surgery, which is restarted. Entirely new pathways and protocols need to be worked out. Methods A panel of experts from the European Hip Society and European Knee Association have agreed to a consensus statement on how to reintroduce elective arthroplasty surgery safely. The recommendations are based on the best available evidence and have been validated in a separate survey. Results The guidelines are based on five themes: modification and/or reorganisation of hospital wards. Restrictions on orthopaedic wards and in operation suite(s). Additional disinfection of the environment. The role of ultra-clean operation theatres. Personal protective equipment enhancement. Conclusion Apart from the following national and local guidance, protocols need to be put in place in the patient pathway for primary arthroplasty to allow for a safe retur

    Recommendations for resuming elective hip and knee arthroplasty in the setting of the SARS‑CoV‑2 pandemic: the European Hip Society and European Knee Associates Survey of Members

    Full text link
    The COVID-19 pandemic has disrupted the health care system around the entire globe. A consensus is needed about resuming total hip and knee procedures. The European Hip Society (EHS) and the European Knee Association (EKA) formed a panel of experts that have produced a consensus statement on how the safe re-introduction of elective hip and knee arthroplasty should be undertaken. Methods A prospective online survey was done among members of EHS and EKA. The survey consisted of 27 questions. It includes basic information on demographics and details the participant’s agreement with each recommendation. The participant could choose among three options (agree, disagree, abstain). Recommendations focussed on pre-operative, perioperative, and post-operative handling of patients and precautions. Results A total of 681 arthroplasty surgeons participated in the survey, with 479 fully completing the survey. The participants were from 44 countries and 6 continents. Apart from adhering to National and Local Guidelines, the recommendations concerned how to make elective arthroplasty safe for patients and staf. Conclusion The survey has shown good-to-excellent agreement of the participants with regards to the statements made in the recommendations for the safe return to elective arthroplasty following the frst wave of the COVID-19 pandemi

    Asian-Specific total knee system: 5-14 year follow-up study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Knee size and body size differ in Asians compared with Caucasians. Nevertheless, many total knee arthroplasty (TKA) prostheses used worldwide are made for Western Caucasian subjects. As a result, an Asian's knee might not fit these prostheses. We studied the Flexible Nichidai Knee (FNK) system, a new model of TKA for Asian patients. The purpose of this report is to investigate the outcomes of this prosthesis retrospectively.</p> <p>Methods</p> <p>We investigated 1055 primary TKAs in 595 patients who underwent FNK for osteoarthritis (OA) in Japan and were followed for > 5 years. The knee score and function score were used for clinical evaluation. We examined the range of motion (ROM) preoperatively and at final follow-up and radiographic assessments. In addition, postoperative complications were investigated. A survivorship analysis was also conducted using two endpoints: revision for any reason and aseptic failure.</p> <p>Results</p> <p>890 knees in 502 patients were available for study (follow-up rate of 96.0%). The mean follow-up term was 8.3 years (range, 5.0-14.1 years). The knee and function score significantly improved from 41.3 to 90.3 and from 39.1 to 76.2 points, respectively (p < 0.001). The mean ROM in FNK posterior cruciate retaining (CR) type and FNK posterior-stabilized (PS) type ameliorated significantly from 107.8° and 95.6° to 110.7° and 110.4°, respectively (p < 0.01). Ten knees underwent revision surgery (infection in 3 cases, instability in 2, loosening in 2, and non-union of femoral supracondylar fracture, severe pain, and recurrent hemarthrosis in 1 each). The survivorship rate was 99.4% (95% CI, 99.0-99.8) at 5 years (n = 952 patients at risk) and 96.2% (95% CI, 91.9-100) at 12.5 years (n = 49 patients at risk).</p> <p>Conclusion</p> <p>The FNK prosthesis for Asians achieved excellent mid- to long-term survivorship and clinical results.</p
    corecore