5 research outputs found

    Baseline characteristics of participants in the Pre-Diabetes Interventions and Continued Tracking to Ease-out Diabetes (Pre-DICTED) Program

    Get PDF
    OBJECTIVE: The Pre-Diabetes Interventions and Continued Tracking to Ease-out Diabetes (Pre-DICTED) Program is a diabetes prevention trial comparing the diabetes conversion rate at 3 years between the intervention group, which receives the incentivized lifestyle intervention program with stepwise addition of metformin, and the control group, which receives the standard of care. We describe the baseline characteristics and compare Pre-DICTED participants with other diabetes prevention trials cohort. RESEARCH DESIGN AND METHODS: Participants were aged between 21 and 64 years, overweight (body mass index (BMI) ≥23.0 kg/m2), and had pre-diabetes (impaired fasting glucose (IFG) and/or impaired glucose tolerance (IGT)). RESULTS: A total of 751 participants (53.1% women) were randomized. At baseline, mean (SD) age was 52.5 (8.5) years and mean BMI (SD) was 29.0 (4.6) kg/m2. Twenty-three per cent had both IFG and IGT, 63.9% had isolated IGT, and 13.3% had isolated IFG. Ethnic Asian Indian participants were more likely to report a family history of diabetes and had a higher waist circumference, compared with Chinese and Malay participants. Women were less likely than men to meet the physical activity recommendations (≥150 min of moderate-intensity physical activity per week), and dietary intake varied with both sex and ethnicity. Compared with other Asian diabetes prevention studies, the Pre-DICTED cohort had a higher mean age and BMI. CONCLUSION: The Pre-DICTED cohort represents subjects at high risk of diabetes conversion. The study will evaluate the effectiveness of a community-based incentivized lifestyle intervention program in an urban Asian context.Peer reviewe

    Comparison of Mean Glandular Dose between Full-Field Digital Mammography and Digital Breast Tomosynthesis

    No full text
    Early detection of breast cancer is diagnosed using mammography, the gold standard in breast screening. However, its increased use also provokes radiation-induced breast malignancy. Thus, monitoring and regulating the mean glandular dose (MGD) is essential. The purpose of this study was to determine MGD for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in the radiology department of a single centre. We also analysed the exposure factors as a function of breast thickness. A total of 436 patients underwent both FFDM and DBT. MGD was auto calculated by the mammographic machine for each projection. Patients’ data included compressed breast thickness (CBT), peak kilovoltage (kVp), milliampere-seconds (mAs) and MGD (mGy). Result analysis showed that there is a significant difference in MGD between the two systems, namely FFDM and DBT. However, the MGD values in our centre were comparable to other centres, as well as the European guideline (<2.5 mGy) for a standard breast. Although DBT improves the clinical outcome and quality of diagnosis, the risk of radiation-induced carcinogenesis should not be neglected. Regular quality control testing on mammography equipment must be performed for dose monitoring in women following a screening mammography in the future

    Study of returns, risks and trading characteristics of SESDAQ firms that have switched to the main board of the SES

    No full text
    246 p.The main objective of this study is to test the hypothesis that there are positive abnormal returns upon the transfer of stocks from SESDAQ to the Main Board of the SES.ACCOUNTANC

    Comparison of Mean Glandular Dose between Full-Field Digital Mammography and Digital Breast Tomosynthesis

    No full text
    Early detection of breast cancer is diagnosed using mammography, the gold standard in breast screening. However, its increased use also provokes radiation-induced breast malignancy. Thus, monitoring and regulating the mean glandular dose (MGD) is essential. The purpose of this study was to determine MGD for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in the radiology department of a single centre. We also analysed the exposure factors as a function of breast thickness. A total of 436 patients underwent both FFDM and DBT. MGD was auto calculated by the mammographic machine for each projection. Patients’ data included compressed breast thickness (CBT), peak kilovoltage (kVp), milliampere-seconds (mAs) and MGD (mGy). Result analysis showed that there is a significant difference in MGD between the two systems, namely FFDM and DBT. However, the MGD values in our centre were comparable to other centres, as well as the European guideline (<2.5 mGy) for a standard breast. Although DBT improves the clinical outcome and quality of diagnosis, the risk of radiation-induced carcinogenesis should not be neglected. Regular quality control testing on mammography equipment must be performed for dose monitoring in women following a screening mammography in the future
    corecore