300 research outputs found

    Totally biological composite aortic stentless valved conduit for aortic root replacement: 10-year experience

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React<sup>® </sup>BioConduit) implanted using the Bentall procedure over ten years in a single centre.</p> <p>Methods</p> <p>Between 27/10/99 and 19/01/08, the No-React<sup>® </sup>BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit.</p> <p>Results</p> <p>Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit).</p> <p>Conclusions</p> <p>The No-React<sup>® </sup>BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade.</p

    Long term follow up after surgery in congenitally corrected transposition of the great arteries with a right ventricle in the systemic circulation

    Get PDF
    Aim of the study: To investigate the long-term outcome of surgical treatment for congenitally corrected transposition of the great arteries (CCTGA), in patients with biventricular repair with the right ventricle as systemic ventricle.Methods: A total of 32 patients with CCTGA were operated between January 1972 and October 2008. These operations comprised 18 patients with a repair with a normal left ventricular outflow tract, 11 patients with a Rastelli repair of the left ventricle to the pulmonary artery and 3 patients with a cardiac transplantation.Results: Excluding the cardiac transplantation patients, mean age at operation was 16 years (sd 15 years, range 1 week - 49 years). Median follow-up was 12 years (sd 10 years, range 7 days - 32 years). Survival obtained from Kaplan-Meier analysis at 20 years after surgery was 63% (CI 53-73%). For the non-Rastelli group these data at 20 years were
    corecore