908 research outputs found
Profilin-1 Is Expressed in Human Atherosclerotic Plaques and Induces Atherogenic Effects on Vascular Smooth Muscle Cells
.Here we monitored profilin-1 expression in human atherosclerotic plaques by immunofluorescent staining. The effects of recombinant profilin-1 on atherogenic signaling pathways and cellular responses such as DNA synthesis (BrdU-incorporation) and chemotaxis (modified Boyden-chamber) were evaluated in cultured rat aortic and human coronary vascular smooth muscle cells (VSMCs). Furthermore, the correlation between profilin-1 serum levels and the degree of atherosclerosis was assessed in humans.<0.001 vs. no atherosclerosis or control group).Profilin-1 expression is significantly enhanced in human atherosclerotic plaques compared to the normal vessel wall, and the serum levels of profilin-1 correlate with the degree of atherosclerosis in humans. The atherogenic effects exerted by profilin-1 on VSMCs suggest an auto-/paracrine role within the plaque. These data indicate that profilin-1 might critically contribute to atherogenesis and may represent a novel therapeutic target
Finerenone Reduces Renal RORγt γδ T Cells and Protects against Cardiorenal Damage
Introduction: Chronic activation of the mineralocorticoid receptor (MR) leads to pathological processes like inflammation and fibrosis during cardiorenal disease. Modulation of immunological processes in the heart or kidney may serve as a mechanistic and therapeutic interface in cardiorenal pathologies. In this study, we investigated anti-inflammatory/-fibrotic and immunological effects of the selective nonsteroidal MR antagonists finerenone (FIN) in the deoxycorticosterone acetate (DOCA)-salt model. Methods: Male C57BL6/J mice were uninephrectomized and received a DOCA pellet implantation (2.4 mg/day) plus 0.9% NaCl in drinking water (DOCA-salt) or received a sham operation and were orally treated with FIN (10 mg/kg/day) or vehicle in a preventive study design. Five weeks after the procedure, blood pressure (BP), urinary albumin/creatinine ratio (UACR), glomerular and tubulointerstitial damage, echocardiographic cardiac function, as well as cardiac/renal inflammatory cell content by FACS analysis were assessed. Results: BP was significantly reduced by FIN. FACS analysis revealed a notable immune response due to DOCA-salt exposure. Especially, infiltrating renal ROR gamma t gamma delta-positive T cells were upregulated, which was significantly ameliorated by FIN treatment. This was accompanied by a significant reduction of UACR in FIN-treated mice. In the heart, FIN reduced DOCA-salt-induced cardiac hypertrophy, cardiac fibrosis and led to an improvement of the global longitudinal strain. Cardiac actions of FIN were not associated with a regulation of cardiac ROR gamma t gamma delta-positive T cells. Discussion/Conclusion: The present study shows cardiac and renal protective effects of FIN in a DOCA-salt model. The cardiorenal protection was accompanied by a reduction of renal ROR gamma t gamma delta T cells. The observed actions of FIN may provide a potential mechanism of its efficacy recently observed in clinical trials
T1 vs. T2 weighted magnetic resonance imaging to assess total kidney volume in patients with autosomal dominant polycystic kidney disease
Purpose: In ADPKD patients total kidney volume (TKV) measurement using MRI is performed to predict rate of disease progression. Historically T1 weighted images (T1) were used, but the methodology of T2 weighted imaging (T2) has evolved. We compared the performance of both sequences. Methods: 40 ADPKD patients underwent an abdominal MRI at baseline and follow-up. TKV was measured by manual tracing with Analyze Direct 11.0 software. Three readers established intra- and interreader coefficients of variation (CV). T1 and T2 measured kidney volumes and growth rates were compared with ICC and Bland-Altman analyses. Results: Participants were 49.7 +/- 7.0 years of age, 55.0% female, with estimated GFR of 50.1 +/- 11.5 mL/min/1.73 m(2). CVs were low and comparable for T2 and T1 (intrareader: 0.83% [0.48-1.79] vs. 1.15% [0.34-1.77], P = 0.9, interreader: 2.18% [1.59-2.61] vs. 1.69% [1.07-3.87], P = 0.9). TKV was clinically similar, but statistically significantly different between T2 and T1: 1867 [1172-2721] vs. 1932 [1180-2551] mL, respectively (P = 0.006), with a bias of only 0.8% and high agreement (ICC 0.997). Percentage kidney growth during 2.2 +/- 0.3 years was similar for T2 and T1 (9.3 +/- 10.6% vs. 7.8 +/- 9.9%, P = 0.1, respectively), with a bias of 1.5% and high agreement (ICC 0.843). T2 was more often of sufficient quality for volume measurement (86.7% vs. 71.1%, P <0.001). Conclusions: In patients with ADPKD, measurement of kidney volume and growth rate performs similarly when using T2 compared to T1 weighted images, although T2 performs better on secondary outcome parameters; they are more often of sufficient quality for volume measurement and result in slightly lower intra- and interreader variability
Measurement of proton electromagnetic form factors in in the energy region 2.00-3.08 GeV
The process of is studied at 22 center-of-mass
energy points () from 2.00 to 3.08 GeV, exploiting 688.5~pb of
data collected with the BESIII detector operating at the BEPCII collider. The
Born cross section~() of is
measured with the energy-scan technique and it is found to be consistent with
previously published data, but with much improved accuracy. In addition, the
electromagnetic form-factor ratio () and the value of the
effective (), electric () and magnetic () form
factors are measured by studying the helicity angle of the proton at 16
center-of-mass energy points. and are determined with
high accuracy, providing uncertainties comparable to data in the space-like
region, and is measured for the first time. We reach unprecedented
accuracy, and precision results in the time-like region provide information to
improve our understanding of the proton inner structure and to test theoretical
models which depend on non-perturbative Quantum Chromodynamics
First observations of hadrons
Based on events collected with
the BESIII detector, five hadronic decays are searched for via process
. Three of them, ,
, and are observed for the first
time, with statistical significances of 7.4, , and
9.1, and branching fractions of ,
, and ,
respectively, where the first uncertainties are statistical and the second
systematic. No significant signal is observed for the other two decay modes,
and the corresponding upper limits of the branching fractions are determined to
be and at 90% confidence level.Comment: 17 pages, 16 figure
Search for the decay
We search for radiative decays into a weakly interacting neutral
particle, namely an invisible particle, using the produced through the
process in a data sample of
decays collected by the BESIII detector
at BEPCII. No significant signal is observed. Using a modified frequentist
method, upper limits on the branching fractions are set under different
assumptions of invisible particle masses up to 1.2 . The upper limit corresponding to an invisible particle with zero mass
is 7.0 at the 90\% confidence level
Precise Measurements of Branching Fractions for Meson Decays to Two Pseudoscalar Mesons
We measure the branching fractions for seven two-body decays to
pseudo-scalar mesons, by analyzing data collected at
GeV with the BESIII detector at the BEPCII collider. The branching fractions
are determined to be ,
,
,
,
,
,
,
where the first uncertainties are statistical, the second are systematic, and
the third are from external input branching fraction of the normalization mode
. Precision of our measurements is significantly improved
compared with that of the current world average values
Measurements of Weak Decay Asymmetries of , , , and
Using production from a 567 pb
data sample collected by BESIII at 4.6 GeV, a full angular analysis is carried
out simultaneously on the four decay modes of , , , and . For the first time, the
transverse polarization is studied in unpolarized
collisions, where a non-zero effect is observed with a statistical significance
of 2.1. The decay asymmetry parameters of the weak
hadronic decays into , , and
are measured to be ,
,
, and
, respectively. In comparison with
previous results, the measurements for the and
modes are consistent but with improved precision, while the parameters for the
and modes are measured for the first time
- …