160 research outputs found
Clinical study of the factors affecting radioulnar deviation of the wrist joint
<p>Abstract</p> <p>Background</p> <p>The radioulnar carpal joint is critical for hand and wrist function. Radioulnar deviation indicates distal radioulnar joint flexibility and reflects the structure and function of the carpal bones, ulna, radius and ligaments. The present study examined whether radioulnar deviation is affected by gender, manual labor, playing a musical instrument, playing sport, handedness, previous fracture or prior inflammation. The study used clinical findings based on anatomical landmarks</p> <p>Methods</p> <p>The ulnar, radial and total deviations for both left and right hands were measured in 300 subjects (157 men and 143 women) of mean age 21.7 years. Measurements were made with the forearm in a fixed pronated position using a novel specially designed goniometer. The gender of each subject was recorded, and information on playing of sport, playing a musical instrument, manual labor, handedness, and history of fracture or inflammation was sought. Data were analyzed using a multifactor ANOVA test.</p> <p>Results</p> <p>No statistically significant difference (p-value > 0.05) was found between those comparing groups except the total deviation of athletes' left hand versus the total deviation of non athletes' left hand (p-value 0.041 < 0.05) and the radial deviation of manual workers' left hand and non manual workers' left hand (p-value 0.002 < 0.05).</p> <p>Conclusions</p> <p>This study was based on clinical findings using anatomical landmarks. We found that manual workers and athletes showed greater left hand flexibility. This suggests that activities that place chronic stress on the radiocarpal joint can independently affect radioulnar deviation.</p
Ultrasound imaging of the carpal tunnel during median nerve compression
Median nerve (MN) compression is a recognized component of carpal tunnel syndrome (CTS). In order to document compressive changes in the MN during hand activity, the carpal tunnel was imaged with neuromuscular ultrasound (NMUS). Ten patients with CTS and five normal controls underwent NMUS of the MN at rest and during dynamic stress testing (DST). DST maneuvers involve sustained isometric flexion of the distal phalanges of the first three digits. During DST in the CTS patients, NMUS demonstrated MN compression between the contracting thenar muscles ventrally and the taut flexor tendons dorsally. The mean MN diameter decreased nearly 40%, with focal narrowing in the mid-distal carpal canal. Normal controls demonstrated no MN compression and a tendency towards MN enlargement, with an average diameter increase of 17%. Observing the pathologic mechanism of MN injury during common prehensile hand movements could help better understand how to treat and prevent CTS
Measurements of knee rotation-reliability of an external device in vivo
<p>Abstract</p> <p>Background</p> <p>Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device.</p> <p>Method</p> <p>The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient <sub>2,1 </sub>(ICC <sub>2,1</sub>), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests.</p> <p>Result</p> <p>ICC<sub>2,1 </sub>ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque.</p> <p>Conclusion</p> <p>The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.</p
Can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilised? A pulsed fluoroscopic investigation
Objectives: Throughout the 20th Century, it has been postulated that the knee moves on the basis of a four-bar link mechanism composed of the cruciate ligaments, the femur and the tibia. As a consequence, the femur has been thought to roll back with flexion, and total knee arthroplasty (TKA) prostheses have been designed on this basis. Recent work, however, has proposed that at a position of between 0° and 120° the medial femoral condyle does not move anteroposteriorly whereas the lateral femoral condyle tends, but is not obliged, to roll back - a combination of movements which equates to tibial internal/femoral external rotation with flexion. The aim of this paper was to assess if the articular geometry of the GMK Sphere TKA could recreate the natural knee movements in situ/in vivo. Methods: The pattern of knee movement was studied in 15 patients (six male: nine female; one male with bilateral TKAs) with 16 GMK Sphere implants, at a mean age of 66 years (53 to 76) with a mean BMI of 30 kg/m2 (20 to 35). The motions of all 16 knees were observed using pulsed fluoroscopy during a number of weight-bearing and non-weight-bearing static and dynamic activities. Results: During maximally flexed kneeling and lunging activities, the mean tibial internal rotation was 8° (standard deviation (SD) 6). At a mean 112° flexion (SD 16) during lunging, the medial and lateral condyles were a mean of 2 mm (SD 3) and 8 mm (SD 4) posterior to a transverse line passing through the centre of the medial tibial concavity. With a mean flexion of 117° (SD 14) during kneeling, the medial and lateral condyles were a mean of 1 mm (SD 4) anterior and 6 mm (SD 4) posterior to the same line. During dynamic stair and pivoting activities, there was a mean anteroposterior translation of 0 mm to 2 mm of the medial femoral condyle. Backward lateral condylar translation occurred and was linearly related to tibial rotation. Conclusion: The GMK Sphere TKA in our study group shows movements similar in pattern, although reduced in magnitude, to those in recent reports relating to normal knees during several activities. Specifically, little or no translation of the medial femoral condyle was observed during flexion, but there was posterior roll-back of the lateral femoral condyle, equating to tibiofemoral rotation. We conclude that the GMK Sphere is anteroposteriorly stable medially and permits rotation about the medial compartment
External rotation during elevation of the arm
Background Knowledge about the pattern of rotation during arm elevation is necessary for a full understanding of shoulder function, and it is also useful for planning of rehabilitation protocols to restore range of motion in shoulders in disorder. However, there are insufficient in vivo data available
Scoliosis treatment using a combination of manipulative and rehabilitative therapy: a retrospective case series
BACKGROUND: The combination of spinal manipulation and various physiotherapeutic procedures used to correct the curvatures associated with scoliosis have been largely unsuccessful. Typically, the goals of these procedures are often to relax, strengthen, or stretch musculotendinous and/or ligamentous structures. In this study, we investigate the possible benefits of combining spinal manipulation, positional traction, and neuromuscular reeducation in the treatment of idiopathic scoliosis. METHODS: A total of 22 patient files were selected to participate in the protocol. Of these, 19 met the study criterion required for analysis of treatment benefits. Anteroposterior radiographs were taken of each subject prior to treatment intervention and 4–6 weeks following the intervention. A Cobb angle was drawn and analyzed on each radiograph, so pre and post comparisons could be made. RESULTS: After 4–6 weeks of treatment, the treatment group averaged a 17° reduction in their Cobb angle measurements. None of the patients' Cobb angles increased. A total of 3 subjects were dismissed from the study for noncompliance relating to home care instructions, leaving 19 subjects to be evaluated post-intervention. CONCLUSIONS: The combined use of spinal manipulation and postural therapy appeared to significantly reduce the severity of the Cobb angle in all 19 subjects. These results warrant further testing of this protocol
The Clinical Assessment Study of the Hand (CAS-HA): a prospective study of musculoskeletal hand problems in the general population
<p>Abstract</p> <p>Background</p> <p>Pain in the hand affects an estimated 12–21% of the population, and at older ages the hand is one of the most common sites of pain and osteoarthritis. The association between symptomatic hand osteoarthritis and disability in everyday life has not been studied in detail, although there is evidence that older people with hand problems suffer significant pain and disability. Despite the high prevalence of hand problems and the limitations they cause in older adults, little attention has been paid to the hand by health planners and policy makers. We plan to conduct a prospective, population-based, observational cohort study designed in parallel with our previously reported cohort study of knee pain, to describe the course of musculoskeletal hand problems in older adults and investigate the relative merits of different approaches to classification and defining prognosis.</p> <p>Methods/Design</p> <p>All adults aged 50 years and over registered with two general practices in North Staffordshire will be invited to take part in a two-stage postal survey. Respondents to the survey who indicate that they have experienced hand pain or problems within the previous 12 months will be invited to attend a research clinic for a detailed assessment. This will consist of clinical interview, hand assessment, screening test of lower limb function, digital photography, plain x-rays, anthropometric measurement and brief self-complete questionnaire. All consenting clinic attenders will be followed up by (i) general practice medical record review, (ii) repeat postal questionnaire at 18-months, and (iii) repeat postal questionnaire at 3 years.</p> <p>Discussion</p> <p>This paper describes the protocol for the Clinical Assessment Study of the Hand (CAS-HA), a prospective, population-based, observational cohort study of community-dwelling older adults with hand pain and hand problems based in North Staffordshire.</p
- …