424 research outputs found
Early Results of Slanted Recession of the Lateral Rectus Muscle for Intermittent Exotropia with Convergence Insufficiency
The aim of this study was to evaluate the efficacy of slanted recession of the lateral rectus muscle for intermittent exotropia with convergence insufficiency. This prospective study included 31 patients who underwent slanted lateral rectus recession for intermittent exotropia with convergence insufficiency between June 2010 and June 2012. Following parameters were recorded and analyzed: patient sex, age, preoperative and postoperative near and distance ocular alignment, and changes in stereopsis. The mean age of the patients was 9.2 years. The preoperative mean deviation angle was 32.4 PD at distance and 43.4 PD at near. After 6 months, slanted lateral rectus recession reduced the deviation angles to 2 PD at distance and 3.4 PD at near. In addition, the mean difference between distance and near deviation angles was significantly reduced from 11 PD to 1.4 PD at 6 months postoperatively. Slanted lateral rectus recession for intermittent exotropia with convergence insufficiency in children successfully reduced the distance and near exodeviations and the near-distance difference without increasing the risk of long-term postoperative esotropia or diplopia
Efficacy of Scrambler Therapy in Patients With Painful Diabetic Peripheral Neuropathy: a Single-arm, Prospective, Pilot Study
BACKGROUND: A variety of medications are available to manage painful diabetic peripheral neuropathy (DPN), but the proper treatment remains challenging. Accordingly, various neuromodulation modalities have been used. However, no prospective clinical trials have evaluated the use of scrambler therapy (ST) in painful DPN. This study aimed to explore the long-term effects of ST in managing painful DPN.
METHODS: The patients received 10 consecutive STs of 45 minutes every 1 to 2 days. The primary outcome was pain score. We measured the visual analog scale (VAS) pain scores at baseline, during ST, immediately after ST, and at 1, 2, 3, and 6 months after ST. The secondary outcomes were Michigan Neuropathy Screening Instrument (MNSI), Semmes-Weinstein monofilament test, and Leeds Assessment of Neuropathic Symptoms and Signs pain scores, which were measured at baseline, immediately after ST, and at 1, 2, 3, and 6 months after ST.
RESULTS: VAS scores showed significant improvement at the 8th, 9th, and 10th sessions during ST and 1 month after ST. The MNSI self-report component score was decreased 1 month after the ST. However, all other outcomes did not show significant differences compared to the baseline.
CONCLUSION: ST may have short-term effects and limited long-term effects on painful DPN
Clinical effectiveness and safety of sirolimus in pediatric patients with complex vascular anomalies: necessitating personalized and comprehensive approaches
BackgroundManaging complex vascular anomalies in pediatric care requires comprehensive approaches. Sirolimus, an mTOR inhibitor with immunosuppressive and anti-angiogenic properties, offers promise. We evaluated sirolimus's effectiveness and safety in pediatric patients with complex vascular anomalies at a tertiary children's hospital.MethodsOur study included 20 patients, aged 1 month to 19 years, with diverse vascular anomalies resistant to conventional therapies or located in high-risk areas precluding surgery. The evaluation of response encompassed measuring the reduction in the size of the targeted vascular or lymphatic lesions as observed on radiologic imaging, along with considering improvements reported by the patients.ResultsPatients used sirolimus for a median of 2.1 years, ranging from 0.6–4.3 years. Results indicated that 60% of patients achieved complete or partial response (CR/PR), whereas 40% had stable disease (SD). Notably, no disease progression occurred. Lesion size assessment was complex, yet patients' self-reported improvements were considered. Three patients reinitiated sirolimus after discontinuation due to worsening lesions. Sirolimus treatment demonstrated good tolerability, with minor complications except for one case of Pneumocystis jiroveci pneumonia. Group comparisons based on response highlighted better outcomes in patients with vascular tumors (CR/PR group 58.0% vs. SD group 0.0%, P = 0.015) or localized measurable lesions (83.3% vs. 12.5%, P = 0.005).ConclusionOur study underscores sirolimus's potential for treating complex vascular anomalies in pediatric patients. Challenges associated with optimal treatment duration and concurrent interventions necessitate a comprehensive approach and genetic testing to optimize outcomes
NFATc1 regulates the transcription of DNA damage-induced apoptosis suppressor
AbstractDNA damage induced apoptosis suppressor (DDIAS), or human Noxin (hNoxin), is strongly expressed in lung cancers. DDIAS knockdown induced apoptosis in non-small cell lung carcinoma A549 cells in response to DNA damage, indicating DDIAS as a potential therapeutic target in lung cancer. To understand the transcriptional regulation of DDIAS, we determined the transcription start site, promoter region, and transcription factor. We found that DDIAS transcription begins at nucleotide 212 upstream of the DDIAS translation start site. We cloned the DDIAS promoter region and identified NFAT2 as a major transcription factor (Im et al., 2016 [1]). We demonstrated that NFATc1 regulates DDIAS expression in both pancreatic cancer Panc-1 cells and lung cancer cells
Fabrication and evaluation of bilateral Helmholtz radiofrequency coil for thermo-stable breast image with reduced artifacts
PURPOSE: The positron emission tomography (PET)-magnetic resonance (MR) system is a newly emerging technique that yields hybrid images with high-resolution anatomical and metabolic information. With PET-MR imaging, a definitive diagnosis of breast abnormalities will be possible with high spatial accuracy and images will be acquired for the optimal fusion of anatomic locations. Therefore, we propose a PET-compatible two-channel breast MR coil with minimal disturbance to image acquisition which can be used for simultaneous PET-MR imaging in patients with breast cancer.
MATERIALS AND METHODS: For coil design and construction, the conductor loops of the Helmholtz coil were tuned, matched, and subdivided with nonmagnetic components. Element values were optimized with an electromagnetic field simulation. Images were acquired on a GE 600 PET-computed tomography (CT) and GE 3.0 T MR system. For this study, we used the T1-weighted image (volunteer; repetition time (TR), 694 ms; echo time (TE), 9.6 ms) and T2-weighted image (phantom; TR, 8742 ms; TE, 104 ms) with the fast spin-echo sequence.
RESULTS: The results of measuring image factors with the proposed radiofrequency (RF) coil and standard conventional RF coil were as follows: signal-to-noise ratio (breast; 207.7 vs. 175.2), percent image uniformity (phantom; 89.22%-91.27% vs. 94.63%-94.77%), and Hounsfield units (phantom; -4.51 vs. 2.38).
CONCLUSIONS: Our study focused on the feasibility of proposed two-channel Helmholtz loops (by minimizing metallic components and soldering) for PET-MR imaging and found the comparable image quality to the standard conventional coil. We believe our work will help significantly to improve image quality with the development of a less metallic breast MR coil
Correlation of the Korean Version of Falls Efficacy Scale-International With Quantitative Balance and Gait Parameters Through Exercise Program in Elderly Men
Objective To determine correlation of the Korean version of Falls Efficacy Scale-International (KFES-I) with other gait and balance parameters through exercise program in older men. Methods Between July 2015 and April 2018, 50 men of 103 participants in an exercise program for preventing falls who aged over 60 years, completed the evaluation before and after the program, had fear of falling (FOF), and could walk independently as an outpatient were enrolled retrospectively. The program comprised lower extremities and core muscle strengthening exercises following stretching exercises twice a week for 8 weeks. FOF using the KFES-I, Berg Balance Scale (BBS), Modified Barthel Index (MBI), stair up and gait categories in MBI (MBI-gait), and Timed Up and Go test (TUG) were evaluated. Quantitative gait and balance parameters were measured by gait analysis, posturography, and isokinetic dynamometer. They were compared before and after the program. Moreover, correlations of KFES-I with other parameters were examined. Results Fifty participants were enrolled. After the program, significant improvements were noted in right stride length (p=0.013) in gait analysis, MBI (p=0.012), BBS (p<0.000), TUG test (p<0.000), and KFES-I (p<0.000) scores. KFES-I was significantly correlated with MBI (r=-0.35, p=0.013), and MBI-gait (r=-0.341, p=0.015). Conclusion Risk of falls could be significantly improved through exercise. KFES-I had significant correlations with MBI-gait parameters. Participants showed increases in gait and balancing ability on quantitative measurements through exercises. Therefore, regular stretching, strengthening, and balancing exercises may help prevent falls in older people
Simultaneous electrochemical detection of both PSMA (+) and PSMA (-) prostate cancer cells using an RNA/peptide dual-aptamer probe
Using an RNA/peptide dual-aptamer probe, both PSMA (+) and PSMA (-) prostate cancer cells were simultaneously detected by electrochemical impedance spectroscopy. This approach can be applied as a general tool for early diagnosis of prostate cancer.CATALONA WJ, 1993, JAMA-J AM MED ASSOC, V270, P948Lupold SE, 2002, CANCER RES, V62, P4029Kue PF, 2002, INT J CANCER, V102, P572, DOI 10.1002/ijc.10734Drummond TG, 2003, NAT BIOTECHNOL, V21, P1192, DOI 10.1038/nbt873DARAIN F, 2004, BIOSENS BIOELECTRON, V20, P856Ban CG, 2004, NUCLEIC ACIDS RES, V32, DOI 10.1093/nar/gnh109Ghosh A, 2004, J CELL BIOCHEM, V91, P528, DOI 10.1002/jcb.10661LEVIN MA, 2005, J UROLOGY, V159, P475Rodriguez MC, 2005, CHEM COMMUN, P4267, DOI 10.1039/b506571bZitzmann S, 2005, CLIN CANCER RES, V11, P139Horninger W, 2001, CANCER-AM CANCER SOC, V91, P1667Lang SH, 2001, BRIT J CANCER, V85, P590Yamamoto T, 2001, UROLOGY, V58, P994Palecek E, 2002, CRIT REV ANAL CHEM, V32, P261Narain V, 2002, CANCER METAST REV, V21, P17Edwards S, 2005, BRIT J CANCER, V92, P376, DOI 10.1038/sj.bjc.6602261Postma R, 2005, EUR J CANCER, V41, P825, DOI 10.1016/j.ejca.2004.12.029Cahova-Kucharikova K, 2005, ANAL CHEM, V77, P2920Rahman MA, 2005, ANAL CHEM, V77, P4854, DOI 10.1021/ac050558vCho M, 2006, NUCLEIC ACIDS RES, V34, DOI 10.1093/nar/gkl364Farokhzad OC, 2006, P NATL ACAD SCI USA, V103, P6315, DOI 10.1073/pnas.0601755103Chu TC, 2006, CANCER RES, V66, P5989, DOI 10.1158/0008-5472.CAN-05-4583McNamara JO, 2006, NAT BIOTECHNOL, V24, P1005, DOI 10.1038/nbt1223Palecek E, 1998, BIOSENS BIOELECTRON, V13, P621Min K, 2008, BIOSENS BIOELECTRON, V23, P1819, DOI 10.1016/j.bios.2008.02.021CHO M, 2008, BMB REPORTS, V41, P119Kim D, 2007, J AM CHEM SOC, V129, P7661, DOI 10.1021/ja071471pMaalouf R, 2007, ANAL CHEM, V79, P4879, DOI 10.1021/ac070085nKRAHN MD, 1994, JAMA-J AM MED ASSOC, V272, P773
Primary Large Cell Neuroendocrine Carcinoma of the Breast: Radiologic and Pathologic Findings
Some breast neoplasms are classified as primary neuroendocrine carcinomas because they are positive for neuroendocrine markers. Although neuroendocrine carcinomas can originate from various organs of the body, primary neuroendocrine carcinomas of the breast are extremely rare. The diagnosis of primary neuroendocrine carcinoma of the breast can only be made if nonmammary sites are confidently excluded or if an in situ component can be found. Here we report a primary large-cell neuroendocrine carcinoma (LCNL) involving the left breast. Breast ultrasonography revealed a lobulated, heterogeneous, low-echoic mass in the left breast, and the lesion ap-peared as a well-defined, highly-enhancing mass on a chest computed tomography scan. Ultrasound-guided core needle biopsy was performed on the mass, and primary LCNC was confirmed by histopathologic examination
- …