171 research outputs found

    A Clinical Study Evaluating an Aspiration-type Semi-Automatic Cutting Biopsy Needle (SCIRO-1702)

    Get PDF
    An aspiration-type semi-automatic cutting biopsy needle enables tissue cutting during application of negative pressure, which is expected to contribute to a larger amount of specimen. The aim of the present study was to evaluate this novel needle in a clinical setting. Patients who underwent image-guided percutaneous biopsy for lung or renal masses were enrolled. Cutting biopsy was performed with and without aspiration during each procedure. The specimens were weighed using an electronic scale. The weights were compared between specimens obtained with and without aspiration using a paired t-test. The data from 45 lung and 30 renal biopsy procedures were analyzed. In lung biopsy, the mean±standard deviation weights of specimens obtained with and without aspiration were 2.20±1.05 mg and 2.24±1.08 mg, respectively. In renal biopsy, the mean weights were 6.52±2.18 mg and 6.42±1.62 mg, respectively. The weights were not significantly different between specimens obtained with and without aspiration either in lung (p=0.799) or renal (p=0.789) biopsies. The application of negative pressure with the aspiration-type semi-automatic cutting biopsy needle did not contribute to an increase in the amount of the specimen obtained in lung and renal biopsies

    Development of high-throughput quantitative analytical method for l-cysteine-containing dipeptides by LC–MS/MS toward its fermentative production

    Get PDF
    l-Cysteine (Cys) is metabolically fundamental sulfur compound and important components in various cellular fac-tors. Interestingly, free-form Cys itself as a simple monomeric amino acid was recently shown to function in a novel antioxidative system (cysteine/cystine shuttle system) in Escherichia coli. However, as for Cys-containing dipeptides, the biological functions, effects, and even contents have still remained largely elusive. The potential functions should be a part of cellular redox system and important in basic and applied biology. For its progress, establishment of reli-able quantitation method is the first. However, such accurate analysis is unexpectedly difficult even in Cys, because thiol compounds convert through disulfide-exchange and air oxidation during sample preparation. Addressing this problem, in this study, thiol molecules like Cys-containing dipeptides were derivatized by using monobromobimane (thiol-specific alkylating reagent) and detected as S-bimanyl derivatives by liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS). Sample separation was processed with a C18 column (2.1 mm × 150 mm, 1.7 μm) and with water-acetonitrile gradient mobile phase containing 0.1% (v/v) formic acid at flow rate of 0.25 ml/min. The mass spectrometer was operated in the multiple reaction monitoring in positive/negative mode with electrospray ionization. The derivatization could indeed avoid the unfavorable reactions, namely, developed the method reflecting their correct contents on sampling. Furthermore, the method was successfully applied to monitoring Cys-containing dipeptides in E. coli Cys producer overexpressing bacD gene. This is the first report of the quantitative analysis of Cys-containing dipeptides, which should be useful for further study of fermentative production of Cys-containing dipeptides

    Ventriculoperitoneal Shunt Outcomes among Infants

    Get PDF
    Ventriculoperitoneal shunts (VPSs) are used for the treatment of hydrocephalus. Here we analyzed the outcomes of VPS placements in 24 infants to determine the risk factors for shunt failure. The infants had undergone the initial VPS operation in our hospital between March 2005 and December 2013. They were observed until the end of January 2014. We obtained Kaplan-Meier curves and performed a multivariate Cox regression analysis of shunt failure. Of the 24 cases, the median (range) values for gestational age, birth weight, and birth head circumference (HC) were 37 (27-39) wks, 2,736 (686-3,788) g, and 35.3 (23.0-45.3) cm, respectively. The total number of shunt procedures was 45. Shunt failure rates were 0.51/shunt and 0.0053/shunt/year. Shunt infection rates were 0.13/shunt and 0.0014/shunt/year. The Kaplan-Meier analysis revealed an increased risk for shunt failure in infants <1 month old or in the HC >90オtile. The Cox regression analysis yielded hazard ratios (HRs) of 2.93 (95オ confidence interval (CI), 0.96-10.95, p=0.059) for age <1 month, and 4.46 (95オCI:1.20-28.91,p=0.023) for the HC >90オtile. The multivariate Cox regression analysis showed adjusted HRs of 17.56 (95オCI:2.69-202.8, p=0.001) for age <1 month, and 2.95 (95オCI:0.52-24.84, p=0.228) for the HC >90オtile. Our findings thus revealed that the risk factors for shunt failure in infants include age <1 month at the initial VPS placement

    In Vivo Microwave Ablation of Normal Swine Lung at High-power, Short-duration Settings

    Get PDF
    To evaluate the volume and heat-sink effects of microwave ablation (MWA) in the ablation zone of the normal swine lung. MWA at 100 W was performed for 1, 2, and 3 min in 7, 5, and 5 lung zones, respectively. We assessed the histopathology in the ablation zones and other outcome measures: namely, length of the longest long and short axes, sphericity, ellipsoid area, and ellipsoid volume. The mean long- and short-axis diameters were 22.0 and 14.1 mm in the 1-min ablation zone, 27.6 and 20.2 mm in the 2-min ablation zone; and 29.2 and 21.2 mm in the 3-min ablation zone, respectively. All measures, except sphericity, were significantly less with 1-min ablation than with either 2- or 3-min ablation. There were no significant differences between the 2- and 3-min ablation zones, but all measures except sphericity were larger with 3-min ablation. Although there were no blood vessels that resulted in a heat-sink effect within the ablation zones, the presence of bronchi nearby in 5 lung ablation zones resulted in reduced ablation size. In high-power, short-duration MWA, the lung ablation volume was affected by ablation time. Some ablations showed that a heat-sink effect by a neighboring bronchus might occur

    Changes in the Features of Invasive Pneumococcal Disease after Introduction of the Seven-valent Pneumococcal Conjugate Vaccine in a Regional Core Hospital of Kochi, Japan

    Get PDF
    Since the introduction of the seven-valent pneumococcal conjugate vaccine (PCV7) in 2007, invasive pneumococcal disease has declined, but the incidence of Streptococcus pneumoniae serotype 19A has risen worldwide. The present study examined changes in the features of invasive pneumococcal disease since the introduction of the PCV7 in Kochi, Japan. Pediatric cases of invasive pneumococcal disease were investigated before and after vaccine introduction (January 2008 to December 2013). Cases of invasive pneumococcal disease tended to decrease after PCV7 introduction. In addition, before introduction of the vaccine, most serotypes causing invasive pneumococcal disease were those included in the vaccine. However, after the introduction, we found cases infected by serotypes not covered by vaccine. Penicillin-resistant S. pneumoniae was the predominant serotype causing invasive pneumococcal disease before introduction of the PCV7, and the susceptibility of this serotype to antibiotics improved after vaccine introduction. Serotype isolates identified after vaccine introduction were also relatively susceptible to antibiotic therapy, but decreased susceptibility is expected

    Basic Study of Susceptibility-Weighted Imaging at 1.5T

    Get PDF
    With the aim of sequence optimization in susceptibility-weighted imaging (SWI), 2 image acquisition parameters (slice thickness and matrix size) and 2 image processing conditions (number of slices per minimum intensity projection (MIP) and Sliding Window) were investigated using a 1.5-T magnetic resonance imaging (MRI) system. The subjects were 12 healthy volunteers and the target region for scanning was the whole brain. Informed consent was obtained from all subjects. First, susceptibility-weighted images were acquired with various slice thicknesses from 1mm to 5mm and various matrix sizes from 256x256 to 512x512, and the images were assessed in terms of the contrast-to-noise ratio (CNR) and were also visually evaluated by three radiologists. Then, the number of slices per MIP and the usefulness of the Sliding Window were investigated. In the study of the optimal slice thickness and matrix size, the results of visual evaluation suggested that a slice thickness of 3mm and a matrix size of 448x448 are optimal, while the results of evaluation based on CNR were not significant. As regards the image processing conditions, the results suggested that the number of slices per MIP should be set to a minimum value of 2 and that the use of Sliding Window is effective. The present study provides useful reference data for optimizing SWI sequences.</p

    Single Center Prospective Phase II Trial of CT-guided Radiofrequency Ablation for Pulmonary Metastases from Colorectal Cancer (SCIRO-1401)

    Get PDF
    The present single center prospective phase II clinical trial is designed to evaluate the efficacy and safety of percutaneous radiofrequency (RF) ablation for colorectal lung metastases. Patients who have colorectal lung metastases without extrapulmonary metastases are included in this study. The primary endpoint is 3-year overall survival (OS) after RF ablation. The secondary endpoints are the prevalence of adverse events within 4 weeks, local tumor progression rate, 1- and 5-year OS, cause-specific survival, and relapse-free survival. The recruitment of patients commenced in July 2014, and the enrolment of 45 patients is intended over the 3 years of study period

    Needle Tract Ablation in Liver Tissue Using a Cryoprobe Combined with an Electrosurgical Device: Influence of ex vivo and in vivo Animal Models

    Get PDF
    To assess the feasibility of needle tract ablation in liver tissue in ex vivo and in vivo animal models using a cryo-probe and electrosurgical device. The experimental device is made by inserting a cryoprobe through an intro-ducer sheath for insulation, with 2-cm of probe tip projecting out. A beagle liver was punctured by the device, and electric current was applied at 30-W with the electrosurgical knife touching the non-insulated device base. The discolored area of cut surface along the device was evaluated in 5 application-time groups (5 , 10 , 15 , 20, or 25 seconds). An ex vivo experiment was performed to determine an ablation algorithm with an appropriate application time by comparison with radiofrequency ablation (RFA) results. Thereafter, an in vivo experiment was performed to verify the algorithm’s feasibility. In the ex vivo model, the cut surface demonstrated different amounts of discolored area according to the application time. The total discolored area in the 20-seconds group was similar to that by RFA. In the in vivo model, the liver did not bleed, the total discolored area was similar to that ex vivo, and coagulation necrosis was confirmed by photomicrograph. Needle tract ablation can be per-formed using the experimental device and electrosurgical device
    corecore