2 research outputs found

    Indoor air quality (IAQ) in a naval ship after refit program: a time variation analysis

    Get PDF
    Refurbishments of the ship's external and internal structures are the main scopes of a refit program. These activities may affect the indoor air quality (IAQ) inside ships and increase the indoor air pollutants (IAP) concentrations onboard. Therefore, continuous IAQ monitoring is needed to determine IAP exposure to the ship's crew. This study evaluates the changes in IAQ conditions inside a naval ship over a two-time interval to determine the effect of compliance with the recommended engineering control measures proposed in the first assessment. Following the standard of the Industry Code of Practice on Indoor Air Quality 2010 (ICOP on IAQ 2010), seven IAQ parameters (temperature, relative humidity (RH), carbon dioxide (CO2), respirable particulates/particulate matter (PM10), total volatile organic compounds (TVOC), bacterial count, and fungal count) were measured in two assessment phases. The first phase was conducted after the ship completed the refit program, and the second phase began three months later, following the execution of the recommended engineering control measures. According to the findings of this study, all IAQ parameters improved when compared to the first phase assessment. However, some of the readings were still non-compliance with the standards of ICOP on IAQ 2010. In conclusion, the ship's IAQ parameters were improved following the recommended engineering control measures, although more enhanced approaches were required to ensure all parameters complied with the ICOP on IAQ 2010

    Indoor Air Quality (IAQ) onboard a naval ship: a comparative study between compartments

    No full text
    Naval ships are made up of confined and enclosed spaces where air circulation is limited. For the Royal Malaysian Navy’s (RMN) ageing assets that are still in service, inefficient ventilation is one of the concerns. This can lead to the elevation of indoor air pollutants (IAP) and worsen indoor air quality (IAQ) onboard, which can indirectly cause Sick Boat Syndrome (SBoS). In order to prevent SBoS, this study aims to assess the IAQ conditions of compartments inside a naval ship and to determine the parameters of compliance with the relevant standards, namely the Industry Code of Practice on Indoor Air Quality 2010 (ICOP IAQ 2010), United States Environmental Protection Agency (US EPA 2006) and Malaysian Ambient Air Quality Standards (MAAQS 2013). In addition, the differences in the IAQ parameters between the ship’s compartments were determined. IAQ assessment was performed at four different compartments, namely the wardroom, cabin, machinery control room (MCR) and bridge, using calibrated handheld IAQ devices. A total of nine parameters were assessed, which were temperature, relative humidity (RH), carbon dioxide (CO2), carbon monoxide (CO), total volatile organic compound (TVOC) particulate matter (PM2.5 and PM10), formaldehyde (CH2O), and nitrogen dioxide (NO2). The differences in IAQ parameters were analysed with IBM SPSS version 26, using the Kruskal-Wallis and Dunn’s Post Hoc tests. The results found that compliance with the standards can be observed for almost all of the IAQ parameters, except for PM10, PM2.5, TVOC, CH2O, and NO2, in several compartments. The Kruskal-Wallis test concluded that there were significant differences in the IAQ parameters in the compartments with p-values < 0.05. The results of Dunn’s Post Hoc test indicated that all sampling points pairwise had significant differences with p-values < 0.05. The incompliance with the standards and variations of the IAQ parameters were attributed to several factors, namely crews’ activities, furnishings and fuel combustion from machinery onboard the ship. In conclusion, continuous monitoring of IAQ is required to ensure good IAQ for the ship’s crew to keep them healthy and improve their productivity. In the bigger picture, good IAQ is needed to ensure the readiness of the naval fleet, to preserve the sovereignty of the country
    corecore