4,044 research outputs found

    Type and Timing of Rehabilitation Following Acute and Subacute Spinal Cord Injury: A Systematic Review

    Get PDF
    Objectives: The objective of this study was to conduct a systematic review of the literature to address the following clinical questions: In adult patients with acute and subacute complete or incomplete traumatic SCI, (1) does the time interval between injury and commencing rehabilitation affect outcome?; (2) what is the comparative effectiveness of different rehabilitation strategies, including different intensities and durations of treatment?; (3) are there patient or injury characteristics that affect the efficacy of rehabilitation?; and (4) what is the cost-effectiveness of various rehabilitation strategies? Methods: A systematic search was conducted for literature published through March 31, 2015 that evaluated rehabilitation strategies in adults with acute or subacute traumatic SCI at any level. Studies were critically appraised individually and the overall strength of evidence was evaluated using methods proposed by the GRADE (Grades of Recommendation Assessment, Development and Evaluation) working group. Results: The search strategy yielded 384 articles, 19 of which met our inclusion criteria. Based on our results, there was no difference between body weight–supported treadmill training and conventional rehabilitation with respect to improvements in Functional Independence Measure (FIM) Locomotor score, Lower Extremity Motor Scores, the distance walked in 6 minutes or gait velocity over 15.2 m. Functional electrical therapy resulted in slightly better FIM Motor, FIM Self-Care, and Spinal Cord Independence Measure Self-Care subscores compared with conventional occupational therapy. Comparisons using the Toronto Rehabilitation Institute Hand Function Test demonstrated no differences between groups in 7 of 9 domains. There were no clinically important differences in Maximal Lean Test, Maximal Sidewards Reach Test, T-shirt Test, or the Canadian Occupational Performance Measure between unsupported sitting training and standard in-patient rehabilitation. Conclusion: The current evidence base for rehabilitation following acute and subacute spinal cord injury is limited. Methodological challenges have contributed to this and further research is still needed. © 2017, © The Author(s) 2017

    Risk algorithm using serial biomarker measurements doubles the number of screen-detected cancers compared with a single-threshold rule in the United Kingdom collaborative trial of ovarian cancer screening

    Get PDF
    PURPOSE: Cancer screening strategies have commonly adopted single-biomarker thresholds to identify abnormality. We investigated the impact of serial biomarker change interpreted through a risk algorithm on cancer detection rates. PATIENTS AND METHODS: In the United Kingdom Collaborative Trial of Ovarian Cancer Screening, 46,237 women, age 50 years or older underwent incidence screening by using the multimodal strategy (MMS) in which annual serum cancer antigen 125 (CA-125) was interpreted with the risk of ovarian cancer algorithm (ROCA). Women were triaged by the ROCA: normal risk, returned to annual screening; intermediate risk, repeat CA-125; and elevated risk, repeat CA-125 and transvaginal ultrasound. Women with persistently increased risk were clinically evaluated. All participants were followed through national cancer and/or death registries. Performance characteristics of a single-threshold rule and the ROCA were compared by using receiver operating characteristic curves. RESULTS: After 296,911 women-years of annual incidence screening, 640 women underwent surgery. Of those, 133 had primary invasive epithelial ovarian or tubal cancers (iEOCs). In all, 22 interval iEOCs occurred within 1 year of screening, of which one was detected by ROCA but was managed conservatively after clinical assessment. The sensitivity and specificity of MMS for detection of iEOCs were 85.8% (95% CI, 79.3% to 90.9%) and 99.8% (95% CI, 99.8% to 99.8%), respectively, with 4.8 surgeries per iEOC. ROCA alone detected 87.1% (135 of 155) of the iEOCs. Using fixed CA-125 cutoffs at the last annual screen of more than 35, more than 30, and more than 22 U/mL would have identified 41.3% (64 of 155), 48.4% (75 of 155), and 66.5% (103 of 155), respectively. The area under the curve for ROCA (0.915) was significantly (P = .0027) higher than that for a single-threshold rule (0.869). CONCLUSION: Screening by using ROCA doubled the number of screen-detected iEOCs compared with a fixed cutoff. In the context of cancer screening, reliance on predefined single-threshold rules may result in biomarkers of value being discarded

    Self-reported transvaginal ultrasound visualization of normal ovaries in postmenopausal women is not reliable: results of expert review of archived images in UKCTOCS.

    Get PDF
    OBJECTIVE: In UKCTOCS self-reported visualization rates(srVR) at annual TVS scan was a key quality control(QC) metric. Our objective was to independently assess srVR using expert review and develop software capable of monitoring it. METHODS: Images from 1,000 examinations randomly selected from 68,951 archived annual TVS exams undertaken between 2008-2011 where the ovaries were reported as 'seen and normal' were reviewed by a single expert. Software was developed to identify exact images used to measure ovaries by measuring caliper dimensions and matching them to that recorded by the sonographer. A logistic regression classifier to determine visualization was trained and validated using ovarian dimension and visualization data reported by the expert . RESULTS: The expert confirmed both ovaries were visualized (cVR-Both) in 50.2%(502/1000) of the exams. The software identified the measurement image in 534 exams which were split 2:1:1 providing training, validating and testing data. Classifier accuracy on validation data was 70.9%(CI-95% 70.0,71.8). Analysis of test data (133 exams) resulted in sensitivity of 90.5%(CI-95% 80.9,95.8) and specificity of 47.5%(CI-95% 34.5,60.8) in detecting expert confirmed cVR-Both. CONCLUSIONS: Our results suggest that in a significant proportion of TVS annual screens the sonographers may have mistaken other structures for normal ovaries. It is uncertain whether or not this affected the sensitivity and stage at detection of ovarian cancer in the ultrasound arm of UKCTOCS, but we conclude QC metrics based on self-reported visualization of normal ovaries are unreliable. The classifier shows some potential for addressing this problem, though further research is needed

    Sonographers' self-reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS.

    Get PDF
    OBJECTIVE: In the UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS), self-reported visualization rate (VR) of the ovaries by the sonographer on annual transvaginal sonographic (TVS) examinations was a key quality control (QC) metric. The objective of this study was to assess self-reported VR using expert review of a random sample of archived images of TVS examinations from UKCTOCS, and then to develop software for measuring VR automatically. METHODS: A single expert reviewed images archived from 1000 TVS examinations selected randomly from 68 931 TVS scans performed in UKCTOCS between 2008 and 2011 with ovaries reported as 'seen and normal'. Software was developed to identify the exact images used by the sonographer to measure the ovaries. This was achieved by measuring caliper dimensions in the image and matching them to those recorded by the sonographer. A logistic regression classifier to determine visualization was trained and validated using ovarian dimensions and visualization data reported by the expert. RESULTS: The expert reviewer confirmed visualization of both ovaries (VR-Both) in 50.2% (502/1000) of the examinations. The software identified the measurement image in 534 exams, which were split 2:1:1 providing training, validation and test data. Classifier mean accuracy on validation data was 70.9% (95% CI, 70.0-71.8%). Analysis of test data (133 exams) provided a sensitivity of 90.5% (95% CI, 80.9-95.8%) and specificity of 47.5% (95% CI, 34.5-60.8%) in detecting expert confirmed visualization of both ovaries. CONCLUSIONS: Our results suggest that, in a significant proportion of TVS annual screens, the sonographers may have mistaken other structures for normal ovaries. It is uncertain whether or not this affected the sensitivity and stage at detection of ovarian cancer in the ultrasound arm of UKCTOCS, but we conclude that QC metrics based on self-reported visualization of normal ovaries are unreliable. The classifier shows some potential for addressing this problem, though further research is needed. © 2017 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology

    Differential Effect of Contrast Polarity Reversals in Closed Squares and Open L-Junctions

    Get PDF
    Scene segmentation depends on interaction between geometrical and photometric factors. It has been shown that reversals in contrast polarity at points of highest orientation discontinuity along closed contours significantly impair shape discrimination performance, while changes in contrast polarity at straight(er) contour segments do not have such deleterious effects (Spehar, 2002). Here we employ (semi) high resolution fMRI (1.5 mm × 1.5 mm × 1.5 mm) to investigate the neuronal substrate underlying these perception effects. Stimuli consisted of simple elements (a) squares with contrast reversals along straight segments; (b) squares with contrast reversals in the corner (highest orientation discontinuity); (c) L-Junctions with contrast reversals along the straight ends; (d) L-Junctions with contrast reversals in the corner. Element with contrast polarity reversals are easy to distinguish though appear geometrically equivalent. For squares with contrast polarity reversals only along straight lines we find significantly lower BOLD modulation compared to any of the control conditions, which show similar responses to each other. In the light of previous psychophysical work (Elder and Zucker, 1993; Spehar, 2002) we speculate that this effect is due to closure perception. We observe this across a wide range of areas on occipital cortex
    • …
    corecore