    Retinal vessel analysis:flicker reproducibility, methodological standardisations and practical limitations

    Get PDF
    The Retinal Vessel Analyser (RVA) is a commercially available ophthalmoscopic instrument capable of acquiring vessel diameter fluctuations in real time and in high temporal resolution. Visual stimulation by means of flickering light is a unique exploration tool of neurovascular coupling in the human retina. Vessel reactivity as mediated by local vascular endothelial vasodilators and vasoconstrictors can be assessed non-invasively, in vivo. In brief, the work in this thesis • deals with interobserver and intraobserver reproducibility of the flicker responses in healthy volunteers • explains the superiority of individually analysed reactivity parameters over vendorgenerated output • links in static retinal measures with dynamic ones • highlights practical limitations in the use of the RVA that may undermine its clinical usefulness • provides recommendations for standardising measurements in terms of vessel location and vessel segment length and • presents three case reports of essential hypertensives in a -year follow-up. Strict standardisation of measurement procedures is a necessity when utilising the RVA system. Agreement between research groups on implemented protocols needs to be met, before it could be considered a clinically useful tool in detecting or predicting microvascular dysfunction

    Minimum intensity projection of embossed quadrant-detection images for improved photoreceptor mosaic visualisation

    Get PDF
    Non-confocal split-detection imaging reveals the cone photoreceptor inner segment mosaic in a plethora of retinal conditions, with the potential of providing insight to ageing, disease, and response to treatment processes, in vivo, and allows the screening of candidates for cell rescue therapies. This imaging modality complements confocal reflectance adaptive optics scanning light ophthalmoscopy, which relies on the waveguiding properties of cones, as well as their orientation toward the pupil. Split-detection contrast, however, is directional, with each cone inner segment appearing as opposite dark and bright semicircles, presenting a challenge for either manual or automated cell identification. Quadrant-detection imaging, an evolution of split detection, could be used to generate images without directional dependence. Here, we demonstrate how the embossed-filtered quadrant-detection images, originally proposed by Migacz et al. for visualising hyalocytes, can also be used to generate photoreceptor mosaic images with better and non-directional contrast for improved visualisation. As a surrogate of visualisation improvement between legacy split-detection images and the images resulting from the method described herein, we provide preliminary results of simple image processing routines that may enable the automated identification of generic image features, as opposed to complex algorithms developed specifically for photoreceptor identification, in pathological retinas

    Retrospective cohort study exploring whether an association exists between spatial distribution of cystoid spaces in cystoid macular oedema secondary to retinitis pigmentosa and response to treatment with carbonic anhydrase inhibitors

    Get PDF
    BACKGROUND: Carbonic anhydrase inhibitors (CAIs) are frequently used as an initial step to treat retinitis pigmentosa-associated cystoid macular oedema (RP-CMO). Interestingly, it has been postulated that CAIs might reduce outer nuclear layer (ONL) fluid more effectively than inner nuclear layer (INL) fluid due to better access to retinal pigment epithelium basolateral membrane than neurosensory retina. This retrospective cohort study explores if an association between spatial distribution of cystoid spaces in RP-CMO and CAI response exists. METHODS: Two independent graders reviewed pretreatment and post-treatment optical coherence tomography (OCT) images of 25 patients (43 eyes) initiated on topical and/or oral CAIs between January 2013 and December 2014. Documentation included the presence/absence of fluid (and layer(s) involved), external limiting membrane, epiretinal membrane (ERM), vitreomacular adhesion/traction, lamellar/full-thickness macular hole and central macular thickness (CMT)/volume. RESULTS: INL fluid was found in all study eyes. All 13 'responders' (at least 11% reduction of CMT after treatment) demonstrated pretreatment ONL fluid. In seven patients (four responders and three non-responders), complete clearance of ONL fluid was achieved despite persistence of INL fluid. ERM presence was similar in responders and non-responders. CONCLUSION: In this study, INL fluid was found to be the most common spatial distribution of RP-CMO. However, patients who were classed as a 'responder' to CAI treatment all demonstrated coexisting ONL fluid on their pretreatment OCT scans. This may be explained by CAIs having better access to retinal pigment epithelium basolateral membrane than neurosensory retina. Our study also suggests a minimal impact on response to CAIs by ERM

    Quantitative Analysis of Hyperautofluorescent Rings to Characterize the Natural History and Progression in Rpgr-associated Retinopathy

    Get PDF
    PURPOSE: Quantitative analysis of hyperautofluorescent rings and progression in subjects with retinitis pigmentosa associated with retinitis pigmentosa GTPase regulator (RPGR) gene mutations. METHODS: Prospective observational study of 46 subjects. Ring area, horizontal and vertical diameter measurements taken from outer and inner ring borders. Intraobserver repeatability, baseline measurements, progression rates, interocular symmetry, and association with age and genotype were investigated. RESULTS: Baseline ring area was 11.8 ± 13.4 mm and 11.4 ± 13.2 mm for right and left eyes, respectively, with very strong interocular correlation (r = 0.9398; P < 0.0001). Ring area constriction was 1.5 ± 2.0 mm/year and 1.3 ± 1.9 mm/year for right and left eyes, respectively, with very strong interocular correlation (r = 0.878, P < 0.0001). Baseline ring area and constriction rate correlated negatively with age (r = -0.767; P < 0.0001 and r = -0.644, P < 0.0001, respectively). Constriction rate correlated strongly with baseline area (r = 0.850, P < 0.0001). Age, but not genotype, exerted a significant effect on constriction rates (P < 0.0001), with greatest rates of progression seen in younger subjects. An exponential decline overall was found. CONCLUSION: This study provides disease-specific baseline values and progression rates together with a repeatability assessment of fundus autofluorescence metrics. Our findings can guide future treatment trials and contribute to the clinical care of patients with RPGR-associated retinitis pigmentosa

    Adaptive optics imaging of inherited retinal diseases.

    Get PDF
    Adaptive optics (AO) ophthalmoscopy allows for non-invasive retinal phenotyping on a microscopic scale, thereby helping to improve our understanding of retinal diseases. An increasing number of natural history studies and ongoing/planned interventional clinical trials exploit AO ophthalmoscopy both for participant selection, stratification and monitoring treatment safety and efficacy. In this review, we briefly discuss the evolution of AO ophthalmoscopy, recent developments and its application to a broad range of inherited retinal diseases, including Stargardt disease, retinitis pigmentosa and achromatopsia. Finally, we describe the impact of this in vivo microscopic imaging on our understanding of disease pathogenesis, clinical trial design and outcome metrics, while recognising the limitation of the small cohorts reported to date

    Adaptive Optics Retinal Imaging in RDH12-Associated Early Onset Severe Retinal Dystrophy

    Get PDF
    PURPOSE: RDH12 is among the most common genes found in individuals with early-onset severe retinal (EOSRD). Adaptive optics scanning light ophthalmoscopy (AOSLO) enables resolution of individual rod and cone photoreceptors in the retina. This study presents the first AOSLO imaging of individuals with RDH12-associated EOSRD. METHODS: Case series of patients who attended Moorfields Eye Hospital (London, UK). Spectral-domain optical coherence tomography, near-infrared reflectance (NIR), and blue autofluorescence imaging were analyzed. En face image sequences of photoreceptors were recorded using either of two AOSLO modalities. Cross-sectional analysis was undertaken for seven patients and longitudinal analysis for one patient. RESULTS: Nine eyes from eight patients are presented in this case series. The mean age at the time of the assessment was 11.2 ± 6.5 years of age (range 7-29). A subfoveal continuous ellipsoid zone (EZ) line was present in eight eyes. Posterior pole AOSLO revealed patches of cone mosaics. Average cone densities at regions of interest 0.5° to the fovea ranged from 12,620 to 23,660 cells/mm2, whereas intercell spacing ranged from 7.0 to 9.7 µm. CONCLUSIONS: This study demonstrates that AOSLO can provide useful high-quality images in patients with EOSRD, even during childhood, with nystagmus, and early macular atrophy. Cones at the posterior pole can appear as scattered islands or, possibly later in life, as a single subfoveal conglomerate. Detailed image analysis suggests that retinal pigment epithelial stress and dysfunction may be the initial step toward degeneration, with NIR being a useful tool to assess retinal well-being in RDH12-associated EOSRD

    A Quantitative and Qualitative Exploration of Photoaversion in Achromatopsia

    Get PDF
    Purpose: Photoaversion (PA) is a disabling and ubiquitous feature of achromatopsia (ACHM). We aimed to help define the characteristics of this important symptom, and present the first published assessment of its impact on patients' lives, as well as quantitative and qualitative PA assessments. Methods: Molecularly confirmed ACHM subjects were assessed for PA using four tasks: structured survey of patient experience, novel quantitative subjective measurement of PA, visual acuities in differing ambient lighting, and objective palpebral aperture-related PA testing. Results: Photoaversion in ACHM was found to be the most significant symptom for a substantial proportion (38%) of patients. A novel subjective PA measurement technique was developed and demonstrated fidelity with more invasive paradigms without exposing often very photosensitive patients to brighter light intensities used elsewhere. An objective PA measurement was also refined for use in trials, indicating that higher light intensities than previously published are likely to be needed. Monocular testing, as required for trials, was also validated for the first time. Conclusions: This study offers new insights into PA in ACHM. It provides the first structured evidence of the great significance of this symptom to patients, suggesting that PA should be considered as an additional outcome measure in therapeutic trials. It also offers new insights into the characteristics of PA in ACHM, and describes both subjective and objective measures of PA that could be employed in clinical trials

    Pathogenic variants in the CYP21A2 gene cause isolated autosomal dominant congenital posterior polar cataracts

    Get PDF
    Background: Congenital cataracts are the most common cause of visual impairment worldwide. Inherited cataract is a clinically and genetically heterogeneous disease. Here we report disease-causing variants in a novel gene, CYP21A2, causing autosomal dominant posterior polar cataract. Variants in this gene are known to cause autosomal recessive congenital adrenal hyperplasia (CAH). / Methods: Using whole-exome sequencing (WES), we have identified disease-causing sequence variants in two families of British and Irish origin, and in two isolated cases of Asian-Indian and British origin. Bioinformatics analysis confirmed these variants as rare with damaging pathogenicity scores. Segregation was tested within the families using direct Sanger sequencing. / Results: A nonsense variant NM_000500.9 c.955 C > T; p.Q319* was identified in CYP21A2 in two families with posterior polar cataract and in an isolated case with unspecified congenital cataract phenotype. This is the same variant previously linked to CAH and identified as Q318* in the literature. We have also identified a rare missense variant NM_000500.9 c.770 T > C; p.M257T in an isolated case with unspecified congenital cataract phenotype. / Conclusion: This is the first report of separate sequence variants in CYP21A2 associated with congenital cataract. Our findings extend the genetic basis for congenital cataract and add to the phenotypic spectrum of CYP21A2 variants and particularly the CAH associated Q318* variant. CYP21A2 has a significant role in mineralo- and gluco-corticoid biosynthesis. These findings suggest that CYP21A2 may be important for extra-adrenal biosynthesis of aldosterone and cortisol in the eye lens

    Severe Loss of Tritan Color Discrimination in RPE65 Associated Leber Congenital Amaurosis

    Get PDF
    Purpose: RPE65-associated Leber congenital amaurosis (RPE65-LCA) is a progressive severe retinal dystrophy with early profound dysfunction of rod photoreceptors followed by progressive cone photoreceptor degeneration. We aim to provide detailed information about how cone dysfunction affects color discrimination. Methods: Seven adults (aged 16-21) with RPE65-LCA underwent monocular color discrimination assessment using the Trivector and Ellipse versions of three computerized tests: Cambridge Colour Test (CCT), low vision version of the Cambridge Colour Test (lvvCCT), and the Universal Colour Discrimination Test (UCDT). For comparison, subjects were also tested using the American Optical Hardy Rand Rittler (AO-HRR) plates. Each assessment was repeated three times. Results: The Trivector version of the tests demonstrated that color discrimination along the tritan axis was undetectable in four subjects, and severely reduced in three subjects. These findings were confirmed by the Ellipse version of the tests. Color discrimination along the protan and deutan axes was evident but reduced in six of seven subjects. Four of seven subjects were unable to read any of the HRR plates. Conclusions: The computerized color vision tests adopted in this study provide detailed information about color discrimination in adult RPE65-LCA patients. The condition is associated with severe impairment of color discrimination, particularly along the tritan axis indicating possible early involvement of S-cones, with additional protan and deutan loss to a lesser extent. This psychophysical assessment strategy is likely to be valuable in measuring the impact of therapeutic intervention on cone function

    Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease

    Get PDF
    INTRODUCTION: To assess inter-device agreement in optical coherence tomography-derived retinal thickness measurements in patients with known macular conditions between spectral-domain and swept-source optical coherence tomography (OCT). METHODS: Two hundred seventy-two subjects were included in the study. They consisted of 91 male (33.5%) and 181 female (66.5%) subjects, and 132 left (48.5%) and 140 right (51.5%) eyes. Each subject underwent spectral-domain OCT (SD-OCT, Spectralis, Heidelberg Engineering; RTVue XR Avanti XR HD, Optovue) and swept-source OCT (SS-OCT; DRI-OCT-1, Atlantis, Topcon) in a single imaging session performed by the same clinical trial-certified technician. The comparison of retinal thickness reproducibility between devices was performed using Bland-Altman analyses and across the entire data set using the intraclass correlation coefficient (ICC). RESULTS: The ICC of the retinal thickness measurements (95% confidence interval) made using all three OCT instruments was 0.81 (0.77-0.84). The mean difference in mean retinal thickness between Spectralis SD-OCT and Topcon SS-OCT was 59.1 μm (95% limit of agreement [LoA] -21.7 to 139.8 μm). The mean difference in mean retinal thickness between Optovue SD-OCT and Topcon SS-OCT was 21.8 μm (95% LoA -34.7  to 78.3 μm). CONCLUSIONS: Retinal layer thickness measurements vary between SS-OCT and SD-OCT devices. We describe inter-device agreement in retinal thickness between SS-OCT and SD-OCT in patients with macular conditions. Clinicians should be aware of the differences in retinal thickness values when imaging patients using different OCT devices and should consider using the same OCT device model in order to monitor clinical change. TRIAL REGISTRATION: ClinicalTrials.gov Identifier (NCT02828215)
    • …