321 research outputs found

    When is proton pump inhibitor use appropriate?

    Get PDF
    Proton pump inhibitor (PPI) therapy is commonly used outside of Food and Drug Administration indication for a broad range of conditions such as extra-esophageal reflux and PPI-responsive esophageal eosinophilia. While this may be appropriate in some scenarios, it has also resulted in widespread inappropriate PPI use. At the same time, data suggesting adverse effects of long-term PPI therapy are multiplying, albeit mainly from low quality studies. The systematic review by Scarpignato et al. (BMC Med 14:179, 2016) addresses this dilemma with a comprehensive analysis of the risks and benefits of PPI use. The authors concluded that, while PPIs are highly efficacious in erosive acid-peptic disorders, efficacy is not equaled in other conditions. In some instances, they found no supportive evidence of benefit. With respect to side effects, they indicated that the questionable harms associated with PPI therapy do not outweigh the benefits afforded by appropriate PPI use. However, inappropriate PPI use results in increased healthcare costs and unnecessary exposure to potential adverse effects. Ideally, PPI therapy should be personalized, based on indication, effectiveness, patient preference, and risk assessment.Please see related article: http://bmcmedicine.biomedcentral.com/articles/10.1186/s12916-016-0718-z

    A fully resolved active musculo-mechanical model for esophageal transport

    Full text link
    Esophageal transport is a physiological process that mechanically transports an ingested food bolus from the pharynx to the stomach via the esophagus, a multi-layered muscular tube. This process involves interactions between the bolus, the esophagus, and the neurally coordinated activation of the esophageal muscles. In this work, we use an immersed boundary (IB) approach to simulate peristaltic transport in the esophagus. The bolus is treated as a viscous fluid that is actively transported by the muscular esophagus, which is modeled as an actively contracting, fiber-reinforced tube. A simplified version of our model is verified by comparison to an analytic solution to the tube dilation problem. Three different complex models of the multi-layered esophagus, which differ in their activation patterns and the layouts of the mucosal layers, are then extensively tested. To our knowledge, these simulations are the first of their kind to incorporate the bolus, the multi-layered esophagus tube, and muscle activation into an integrated model. Consistent with experimental observations, our simulations capture the pressure peak generated by the muscle activation pulse that travels along the bolus tail. These fully resolved simulations provide new insights into roles of the mucosal layers during bolus transport. In addition, the information on pressure and the kinematics of the esophageal wall due to the coordination of muscle activation is provided, which may help relate clinical data from manometry and ultrasound images to the underlying esophageal motor function

    A continuum mechanics-based musculo-mechanical model for esophageal transport

    Get PDF
    In this work, we extend our previous esophageal transport model using an immersed boundary (IB) method with discrete fiber-based structural model, to one using a continuum mechanics-based model that is approximated based on finite elements (IB-FE). To deal with the leakage of flow when the Lagrangian mesh becomes coarser than the fluid mesh, we employ adaptive interaction quadrature points to deal with Lagrangian-Eulerian interaction equations based on a previous work (Griffith and Luo [1]). In particular, we introduce a new anisotropic adaptive interaction quadrature rule. The new rule permits us to vary the interaction quadrature points not only at each time-step and element but also at different orientations per element. This helps to avoid the leakage issue without sacrificing the computational efficiency and accuracy in dealing with the interaction equations. For the material model, we extend our previous fiber-based model to a continuum-based model. We present formulations for general fiber-reinforced material models in the IB-FE framework. The new material model can handle non-linear elasticity and fiber-matrix interactions, and thus permits us to consider more realistic material behavior of biological tissues. To validate our method, we first study a case in which a three-dimensional short tube is dilated. Results on the pressure-displacement relationship and the stress distribution matches very well with those obtained from the implicit FE method. We remark that in our IB-FE case, the three-dimensional tube undergoes a very large deformation and the Lagrangian mesh-size becomes about 6 times of Eulerian mesh-size in the circumferential orientation. To validate the performance of the method in handling fiber-matrix material models, we perform a second study on dilating a long fiber-reinforced tube. Errors are small when we compare numerical solutions with analytical solutions. The technique is then applied to the problem of esophageal transport. We use two fiber-reinforced models for the esophageal tissue: a bi-linear model and an exponential model. We present three cases on esophageal transport that differ in the material model and the muscle fiber architecture. The overall transport features are consistent with those observed from the previous model. We remark that the continuum-based model can handle more realistic and complicated material behavior. This is demonstrated in our third case where a spatially varying fiber architecture is included based on experimental study. We find that this unique muscle fiber architecture could generate a so-called pressure transition zone, which is a luminal pressure pattern that is of clinical interest. This suggests an important role of muscle fiber architecture in esophageal transport

    Direct and retrograde signal propagation in unidirectionally coupled Wilson-Cowan oscillators

    Full text link
    Certain biological systems exhibit both direct and retrograde propagating wave signals, despite unidirectional neural coupling. However, there is no model to explain this. Therefore, the underlying physics of reversing the signal's direction for one-way coupling remains unclear. Here, we resolve this issue using a Wilson-Cowan oscillators network. By analyzing the limit cycle period of various coupling configurations, we determine that intrinsic frequency differences among oscillators control wave directionality

    A mechanics--based perspective on the function of human sphincters during functional luminal imaging probe manometry

    Full text link
    Functional luminal imaging probe (FLIP) is used to measure cross-sectional area (CSA) and pressure at sphincters. It consists of a catheter surrounded by a fluid filled cylindrical bag, closed on both ends. Plotting the pressure-CSA hysteresis of a sphincter during a contraction cycle, which is available through FLIP testing, offers information on its functionality, and can provide diagnostic insights. However, limited work has been done to explain the mechanics of these pressure-CSA loops. This work presents a consolidated picture of pressure-CSA loops of different sphincters. Clinical data reveal that although sphincters have a similar purpose (controlling the flow of liquids and solids by opening and closing), two different pressure-CSA loop patterns emerge: negative slope loop (NSL) and positive slope loop (PSL). We show that the loop type is the result of an interplay between (or lack thereof) two mechanical modes: (i) neurogenic mediated relaxation of the sphincter muscle and (ii) muscle contraction proximal to the sphincter which causes mechanical distention. We conclude that sphincters which only function through mechanism (i) exhibition NSL whereas sphincters which open as a result of both (i) and (ii) display a PSL. This work provides a fundamental mechanical understanding of human sphincters. This can be used to identify normal and abnormal phenotypes for the different sphincters and help in creating physiomarkers based on work calculation

    Neurological disorders leading to mechanical dysfunction of the esophagus: an emergent behavior of a neuromechanical dynamical system

    Full text link
    An understanding how neurological disorders lead to mechanical dysfunction of the esophagus requires knowledge of the neural circuit of the enteric nervous system. Historically, this has been elusive. Here, we present an empirically guided neural circuit for the esophagus. It has a chain of unidirectionally coupled relaxation oscillators, receiving excitatory signals from stretch receptors along the esophagus. The resulting neuromechanical model reveals complex patterns and behaviors that emerge from interacting components in the system. A wide variety of clinically observed normal and abnormal esophageal responses to distension are successfully predicted. Specifically, repetitive antegrade contractions (RACs) are conclusively shown to emerge from the coupled neuromechanical dynamics in response to sustained volumetric distension. Normal RACs are shown to have a robust balance between excitatory and inhibitory neuronal populations, and the mechanical input through stretch receptors. When this balance is affected, contraction patterns akin to motility disorders are observed. For example, clinically observed repetitive retrograde contractions emerge due to a hyper stretch sensitive wall. Such neuromechanical insights could be crucial to eventually develop targeted pharmacological interventions

    Esophageal motility disorders on high-resolution manometry: Chicago classification version 4.0©

    Full text link
    Chicago Classification v4.0 (CCv4.0) is the updated classification scheme for esophageal motility disorders using metrics from high-resolution manometry (HRM). Fifty-two diverse international experts separated into seven working subgroups utilized formal validated methodologies over two-years to develop CCv4.0. Key updates in CCv.4.0 consist of a more rigorous and expansive HRM protocol that incorporates supine and upright test positions as well as provocative testing, a refined definition of esophagogastric junction (EGJ) outflow obstruction (EGJOO), more stringent diagnostic criteria for ineffective esophageal motility and description of baseline EGJ metrics. Further, the CCv4.0 sought to define motility disorder diagnoses as conclusive and inconclusive based on associated symptoms, and findings on provocative testing as well as supportive testing with barium esophagram with tablet and/or functional lumen imaging probe. These changes attempt to minimize ambiguity in prior iterations of Chicago Classification and provide more standardized and rigorous criteria for patterns of disorders of peristalsis and obstruction at the EGJ

    Evaluation of Esophageal Motility Utilizing the Functional Lumen Imaging Probe

    Get PDF
    © 2016 by the American College of Gastroenterology. Objectives:Esophagogastric junction (EGJ) distensibility and distension-mediated peristalsis can be assessed with the functional lumen imaging probe (FLIP) during a sedated upper endoscopy. We aimed to describe esophageal motility assessment using FLIP topography in patients presenting with dysphagia.Methods:In all, 145 patients (aged 18-85 years, 54% female) with dysphagia that completed up per endoscopy with a 16-cm FLIP assembly and high-resolution manometry (HRM) were included. HRM was analyzed according to the Chicago Classification of esophageal motility disorders; major esophageal motility disorders were considered "abnormal". FLIP studies were analyzed using a customized program to calculate the EGJ-distensibility index (DI) and generate FLIP topography plots to identify esophageal contractility patterns. FLIP topography was considered "abnormal" if EGJ-DI was < 2.8 mm 2 /mm Hg or contractility pattern demonstrated absent contractility or repetitive, retrograde contractions.Results:HRM was abnormal in 111 (77%) patients: 70 achalasia (19 type I, 39 type II, and 12 type III), 38 EGJ outflow obstruction, and three jackhammer esophagus. FLIP topography was abnormal in 106 (95%) of these patients, including all 70 achalasia patients. HRM was "normal" in 34 (23%) patients: five ineffective esophageal motility and 29 normal motility. In all, 17 (50%) had abnormal FLIP topography including 13 (37%) with abnormal EGJ-DI.Conclusions:FLIP topography provides a well-tolerated method for esophageal motility assessment (especially to identify achalasia) at the time of upper endoscopy. FLIP topography findings that are discordant with HRM may indicate otherwise undetected abnormalities of esophageal function, thus FLIP provides an alternative and complementary method to HRM for evaluation of non-obstructive dysphagia.Link_to_subscribed_fulltex
    • …
    corecore