3,080 research outputs found

    Generation of tunable, high repetition rate optical frequency combs using on-chip silicon modulators

    Full text link
    We experimentally demonstrate tunable, highly-stable frequency combs with high repetition-rates using a single, charge injection based silicon PN modulator. In this work, we demonstrate combs in the C-band with over 8 lines in a 20-dB bandwidth. We demonstrate continuous tuning of the center frequency in the C-band and tuning of the repetition-rate from 7.5GHz to 12.5GHz. We also demonstrate through simulations the potential for bandwidth scaling using an optimized silicon PIN modulator. We find that, the time varying free carrier absorption due to carrier injection, an undesirable effect in data modulators, assists here in enhancing flatness in the generated combs.Comment: 10 pages, 7 figure

    Asymmetry to symmetry transition of Fano line-shape: Analytical derivation

    Full text link
    An analytical derivation of Fano line-shape asymmetry ratio has been presented here for a general case. It is shown that Fano line-shape becomes less asymmetric as \q is increased and finally becomes completely symmetric in the limiting condition of q equal to infinity. Asymmetry ratios of Fano line-shapes have been calculated and are found to be in good consonance with the reported expressions for asymmetry ratio as a function of Fano parameter. Application of this derivation is also mentioned for explanation of asymmetry to symmetry transition of Fano line-shape in quantum confined silicon nanostructures.Comment: 3 figures, Latex files, Theoretica

    Observation of An Evolving Magnetic Flux Rope Prior To and During A Solar Eruption

    Full text link
    Explosive energy release is a common phenomenon occurring in magnetized plasma systems ranging from laboratories, Earth's magnetosphere, the solar corona and astrophysical environments. Its physical explanation is usually attributed to magnetic reconnection in a thin current sheet. Here we report the important role of magnetic flux rope structure, a volumetric current channel, in producing explosive events. The flux rope is observed as a hot channel prior to and during a solar eruption from the Atmospheric Imaging Assembly (AIA) telescope on board the Solar Dynamic Observatory (SDO). It initially appears as a twisted and writhed sigmoidal structure with a temperature as high as 10 MK and then transforms toward a semi-circular shape during a slow rise phase, which is followed by fast acceleration and onset of a flare. The observations suggest that the instability of the magnetic flux rope trigger the eruption, thus making a major addition to the traditional magnetic-reconnection paradigm.Comment: 13 pages, 3 figure

    Optimising use of electronic health records to describe the presentation of rheumatoid arthritis in primary care: a strategy for developing code lists

    Get PDF
    Background Research using electronic health records (EHRs) relies heavily on coded clinical data. Due to variation in coding practices, it can be difficult to aggregate the codes for a condition in order to define cases. This paper describes a methodology to develop ‘indicator markers’ found in patients with early rheumatoid arthritis (RA); these are a broader range of codes which may allow a probabilistic case definition to use in cases where no diagnostic code is yet recorded. Methods We examined EHRs of 5,843 patients in the General Practice Research Database, aged ≥30y, with a first coded diagnosis of RA between 2005 and 2008. Lists of indicator markers for RA were developed initially by panels of clinicians drawing up code-lists and then modified based on scrutiny of available data. The prevalence of indicator markers, and their temporal relationship to RA codes, was examined in patients from 3y before to 14d after recorded RA diagnosis. Findings Indicator markers were common throughout EHRs of RA patients, with 83.5% having 2 or more markers. 34% of patients received a disease-specific prescription before RA was coded; 42% had a referral to rheumatology, and 63% had a test for rheumatoid factor. 65% had at least one joint symptom or sign recorded and in 44% this was at least 6-months before recorded RA diagnosis. Conclusion Indicator markers of RA may be valuable for case definition in cases which do not yet have a diagnostic code. The clinical diagnosis of RA is likely to occur some months before it is coded, shown by markers frequently occurring ≥6 months before recorded diagnosis. It is difficult to differentiate delay in diagnosis from delay in recording. Information concealed in free text may be required for the accurate identification of patients and to assess the quality of care in general practice

    SUMO chain formation is required for response to replication arrest in S. pombe

    Get PDF
    SUMO is a ubiquitin-like protein that is post-translationally attached to one or more lysine residues on target proteins. Despite having only 18% sequence identity with ubiquitin, SUMO contains the conserved betabetaalphabetabetaalphabeta fold present in ubiquitin. However, SUMO differs from ubiquitin in having an extended N-terminus. In S. pombe the N-terminus of SUMO/Pmt3 is significantly longer than those of SUMO in S. cerevisiae, human and Drosophila. Here we investigate the role of this N-terminal region. We have used two dimensional gel electrophoresis to demonstrate that S. pombe SUMO/Pmt3 is phosphorylated, and that this occurs on serine residues at the extreme N-terminus of the protein. Mutation of these residues (in pmt3-1) results in a dramatic reduction in both the levels of high Mr SUMO-containing species and of total SUMO/Pmt3, indicating that phosphorylation of SUMO/Pmt3 is required for its stability. Despite the significant reduction in high Mr SUMO-containing species, pmt3-1 cells do not display an aberrant cell morphology or sensitivity to genotoxins or stress. Additionally, we demonstrate that two lysine residues in the N-terminus of S. pombe SUMO/Pmt3 (K14 and K30) can act as acceptor sites for SUMO chain formation in vitro. Inability to form SUMO chains results in aberrant cell and nuclear morphologies, including stretched and fragmented chromatin. SUMO chain mutants are sensitive to the DNA synthesis inhibitor, hydroxyurea (HU), but not to other genotoxins, such as UV, MMS or CPT. This implies a role for SUMO chains in the response to replication arrest in S. pomb

    Spectroscopic investigation of quantum confinement effects in ion implanted silicon-on-sapphire films

    Full text link
    Crystalline Silicon-on-Sapphire (SOS) films were implanted with boron (B+^+) and phosphorous (P+^+) ions. Different samples, prepared by varying the ion dose in the range 101410^{14} to 5 x 101510^{15} and ion energy in the range 150-350 keV, were investigated by the Raman spectroscopy, photoluminescence (PL) spectroscopy and glancing angle x-ray diffraction (GAXRD). The Raman results from dose dependent B+^+ implanted samples show red-shifted and asymmetrically broadened Raman line-shape for B+^+ dose greater than 101410^{14} ions cm2^{-2}. The asymmetry and red shift in the Raman line-shape is explained in terms of quantum confinement of phonons in silicon nanostructures formed as a result of ion implantation. PL spectra shows size dependent visible luminescence at \sim 1.9 eV at room temperature, which confirms the presence of silicon nanostructures. Raman studies on P+^+ implanted samples were also done as a function of ion energy. The Raman results show an amorphous top SOS surface for sample implanted with 150 keV P+^+ ions of dose 5 x 101510^{15} ions cm2^{-2}. The nanostructures are formed when the P+^+ energy is increased to 350 keV by keeping the ion dose fixed. The GAXRD results show consistency with the Raman results.Comment: 9 Pages, 6 Figures and 1 Table, \LaTex format To appear in SILICON(SPRINGER

    Studies on Formulation and Evaluation of Ethyl Cellulose Based Extended Release Metformin Hydrochloride Matrix Tablets

    Get PDF
    Monolithic matrix tablets of metformin hydrochloride were formulated as extended release tablets by employing ethyl cellulose polymer and the extended release characterization of the formulated tablets was investigated.  Extended release matrix tablets containing 500 mg metformin hydrochloride were developed by changing concentration of drug :  polymer (EC) in the ratio of 5:1, 5:2, 5:3 and 5:4 by direct compression.  Formulations were optimized based on the acceptable tablet properties invitro and invivo drug release.  The resulting formulations produced robust tablets with optimum hardness, weight variation, drug content and low friability.  The result of invitro and invivo drug release studies indicated that formulation (drug:polymer =5:3), is the most successful of the study and exhibited constant and extended release of metformin hydrochloride 99-100.5% release at the end of 10 h compared with reference standard.  Further, the formulation F3 was subjected to exposure at room and accelerated condition to stability studies.  A decrease in release of the drug was observed on increasing polymer ratio at certain level.  Before tablet compression, the resulting formulation blends were evaluated for angle of repose, bulk density, % porosity, % compressibility index and drug polymer compatibility study of drug and excipients.  The t25, t50 and t90 drug release values was calculated from selected formulation F3 on every month of stability studies and comparision of both room and accelerated condition by statistical t-test, there is no difference between storage temperature. The formulation F3 was showed similar invitro and invivo drug release when compared to marketed sustained release tablet (F5M)
    corecore