216 research outputs found

    Um sistema nacional de aquisição e processamento de dados acoplado "on line" ao espectrômetro de massa de fonte sólida TH-5 (Varian Mat)

    Get PDF
    A VARIAN MAT solid source mass spectrometer, varían model MAT TH-5, used for geochronological applications has been coupled on line to a 16-bit HP-9825B computer. An appropriate digital voltimeter and interface, both supplied by Hewlett-Packard, complete the system. The developed prototype allows, through peak switching of 8 channels controlled by a Hall effect probe, isotopic analyses of all the elements which can be carried out by the thermal ionization method. This system has been used since 1983 with success, and the strontium measurements performed on 2 carbonate standards NBS-987 and SrN (E&A) agree, within experimental error, with results obtained in modem instruments. A similar system, with the same performance capabilities as the one described above, using an Apple computer and peripherals available in Brazil, has also been developed. The developed interface is provided with outputs to control external devices and accessories like solenoid valves, vacuum systems, scales, etc, common is mass spectrometry. The software, available in HPL and Applesoft languages, is provided with dinamic interference correction, Dodson's interpolation technique, rejection of the spurious ratios and computes all the common statistical parameters.Um espectrômetro de massa de fonte sólida da VARIAN MAT, modelo TH-5, utilizado em aplicações geocronológicas, foi acoplado "on line" ao microcomputador HP-9825B de 16 bits, tendo um voltímetro digital e interfaces apropriadas da Hewlett-Packard. O protótipo desenvolvido permite, através da técnica de "peak switching" de 8 canais controlados por uma sonda de efeito Hall, medidas isotópicas de todos os elementos analisáveis pelo método de ionização térmica. O sistema utilizado desde 1983, com amplo sucesso, rivaliza com os sistemas modernos conforme medidas efetuadas em 2 carbonatos padrões de estrôncio NBS-987 e SrN (E & A). Experiência semelhante, utilizando um microcomputador da linha Apple, periféricos e interface apropriados e inteiramente nacionais desenvolvidos para o sistema, reproduziu, de forma bastante adequada, a performance anterior. A interface desenvolvida, pela sua versatilidade, pode acionar periféricos e acessórios como válvulas solenóides, sistemas de vácuo, sistema de troca de escala, etc, operações comuns na espectrometria. O software, desenvolvido nas linguagens HPL e Applesoft, é provido de correção de interferência dinâmica, técnica de interpolação de Dodson, rejeição de razões espúrias e cálculos de todos os parâmetros estatísticos normais

    Numerical modelling of UHMWPE composites under impact loading

    Get PDF

    Regressões lineares em geocronologia: isócronas, errócronas e pseudoisócronas

    Get PDF

    Regressões lineares em geocronologia: isócronas, errócronas e pseudoisócronas

    Get PDF
    Several methods of linear regression reported in the literature for use in geochonology are discussed in order to guide geochronologists in the selection of an adequate model and also to distinguish among isochrons, errorchrons and pseudoisochrons. For Rb/Sr isochron methods, at least 6 models or statistical treatments are available, each one with its peculiarities. Based in two examples, we show that for cases when the experimental data points scatter within limits determined by the experimental errors, and using or not the weighted regression treatment, the resultant parameters are essentially concordant. The estimates of associated error, however especially for initial ratios, show variations by up to a factor of 7, depending upon the statistical procedure. In view of this fact and on the basis of simulated test data, we propose not only more adequate models, but also general criteria that must be observed in the selection of samples in order to obtain an isochron. If the data to be regressed show a scatter in excess of experimental error for geological reasons (open system), four regression models are available to treat the parameters defined in these cases as errorchrons. These models are briefly discussed in terms of their applications. In the Pb/U methods, in which the usual regression treatment is applied to obtain the best-fit line, some additional peculiarities are pointed outDiversos métodos de regressão linear propostos na literatura, para fins geocronológicos, são discutidos de modo a orientar os geocronólogos na escolha de modelos adequados e também distinguir entre isócronas, errócronas ou pseudoisócronas. No caso do método isocrôni co Rb/Sr, são disponíveis pelo menos 6 modelos ou abordagens estatísticas, cada qual com peculiaridades específicas. Exemplifica-se o caso em que os pontos se alinham dentro dos erros experimentais e utilizando modelos, adequados ou não, que empregam a técnica de pondera ção dos pontos, os parâmetros resultantes são praticamente concordantes, porém os erros podem variar até por um fator tão alto quanto 7, conforme a formulação estatística proposta. Em vista deste fato, propõem-se, com base também em exemplos, os modelos mais adequados e também critérios gerais que devem ser observados até na seleção de amostras para a obtenção de isócronas. Nos casos em que os pontos não se alinham dentro dos erros experimentais, por causas geológicas (sistema aberto), são abordados 4 dos modelos sugeridos e é feita também uma discussão em que casos seriam aplicáveis. No método da concórdia Pb/U, em que as regressões usuais também são aplicáveis para determinar a melhor reta, algumas particularidades adicionais são discutida

    Prostaglandin E2 Reverses Aberrant Production of an Inflammatory Chemokine by Microglia from Sandhoff Disease Model Mice through the cAMP-PKA Pathway

    Get PDF
    Background: Sandhoff disease (SD) is a neurodegenerative lysosomal b-hexosaminidase (Hex) deficiency involving excessive accumulation of undegraded substrates, including terminal GlcNAc-oligosaccharides and GM2 ganglioside. Microglia-mediated neuroinflammation contributes to the pathogenesis and progression of SD. Our previous study demonstrated that MIP-1a, a putative pathogenic factor for SD, is up-regulated in microglial cells derived from SD model mice (SD-Mg) through activation of Akt and JNK. Methodology/Principal Findings: In this study, we first demonstrated that prostaglandin E2 (PGE2), which is one of the lipid mediators derived from arachidonic acid and is known to suppress activation of microglia, reduced the aberrant MIP-1a production by SD-Mg to the same level as by WT-Mg. PGE2 also attenuated the activation of Akt and JNK. The inhibition of MIP-1a production and the activation of Akt and JNK occurred through the EP2 and 4/cAMP/PKA signaling pathway in the murine microglia derived from SD model mice. Conclusions/Significance: We propose that PGE2 plays a role as a negative regulator of MIP-1a production in th
    • …
    corecore