19 research outputs found

    Comparison of dynamic of autonomic control indices in cardiovascular system under the treatment by ACE inhibitor (Enalapril) and beta-blocker (Metoprolol) in patients with hypertension

    Get PDF
    The objective of the present research was to compare the influence of Enalapril and Metoprolol on synchronization of 0.1 Hz-regulation of heart and blood microcirculation. 42 patients aged 49±9 years old with hypertension I, II were included in the study. 0.1 Hz-oscillations in heart rate variability (HRV) and blood microcirculation were registered during the passive orthostatic sign while breathing spontaneously. The duration of each test was 10 minutes. Synchronization was estimated as a phase difference between 0.1 Hz-rhythms in heart rate and in filling of blood microcirculation. Quantitative measures of synchronization were also estimated. In addition frequency values of HRV spectrum in LF- and HF-ranges were assessed. Enalapril and Metoprolol had comparable effect on blood pressure reduction. Treatment with both Enalapril and Metoprolol in patients with significant vegetative dysfunction resulted in repair of functional interaction between 0.1 Hz-regulation of heart and blood microcirculation. Enalapril was preferred in hypertensive patients with prevalence of disorders of vegetative regulation of blood microcirculation. Metoprolol influenced positively on 0,1 Hz-rhythm synchronization in patients with predominance of heart vegetative regulation dysfunction and in patients with sympathicotonia. In patients with hypertension and initially normal level of synchronization of 0.1 Hz-mechanisms treatment with Enalapril or Metoprolol caused functional dissociation. Differentiated approach to the choice of hypertensive therapy should consider individual peculiarities of system vegetative dysfunction. The level of synchronization of 0.1 Hz-rhythms in cardiovascular system should especially be evaluated initially and during the treatmen

    Comparative evaluation of autonomic regulation of circulation in patients undergone coronary artery bypass grafting or correction of acquired valvular heart disease

    Get PDF
    The aim of the research was to study the peculiarities of vegetative regulation of blood circulation in cardiac surgery patients who underwent coronary artery bypass grafting (CABG) or correction of acquired valvular heart disease (CAVHD). Material and Methods. In this study we included 42 patients (12 women; 63 (57; 67) years), who underwent CABG, and 36 patients (16 women; 58 (47; 65) years) who underwent CAVHD. The synchronous 15 minutes records of electrocardiogram and photoplethysmogram (PPG) were performed in all patients before and after surgery. Time domain and frequency domain measures of heart rate variability (HRV) and index of synchronization between low-frequency (LF) oscillations in HRV and PPG (index S) were analyzed. Results. Most studied autonomic indices did not have statistically significant differences between patients with CABG and CAVHD in the study stages, except for heart rate, which was higher in patients before CAVHD (p=0,013). Conclusion. The values of HRV and index S do not depend on the difference in the clinical status and the features of performed cardiac surgical interventions between patients with CABG and CAVHD.</p

    Some luminescence characteristics of allocytoplasmic wheat hybrids

    No full text
    Comparative studies of thermoluminescence and slow fluorescence induction were carried out on leaves of allocytoplasmic hybrids and standard regionalized wheat (cultivar Zarya). There are differences in luminescence indices between these objects correlated to the thermoluminescence and slow fluorescence induction methods. These differences allow estimation of the functional activity of the photosynthetic system. All studied allocytoplasmic hybrids exceeded the standard wheat in both luminescence indices F-M/F-T(slow fluorescence induction) and S-A/S-tot (thermoluminescence) and productivity (height of seedlings, number of ears and grains, grain mass, etc.). The highest values of F-M/F-T and S-A/S-tot and the lowest value of S-C/S-tot were recorded in the allocytoplasmic hybrid Igen 3 x Mironovskaya 808, which is characterized by the highest productivity

    МЕДЛЕННАЯ ИНДУКЦИЯ ФЛУОРЕСЦЕНЦИИ И ПРОДУКТИВНОСТЬ ЯЧМЕНЯ, ОБРАБОТАННОГО CВЕРХКРИТИЧЕСКИМ ФЛЮИДНЫМ ЭКСТРАКТОМ АМАРАНТА

    No full text
    ПЕРЕВОДНАЯ ВЕРСИЯ: SLOW FLUORESCENCE INDUCTION AND PRODUCTIVITY OF BARLEY TREATED WITH A SUPERCRITICAL FLUID EXTRACT OF AMARANTH / Karavaev V.A., Glazunova S.A., Levykina I.P. [и др.] // Biophysics. 2012. Т. 57. № 4. С. 502-503Показано, что обpаботка pаcтений ячменя cвеpxкpитичеcким флюидным экcтpактом амаpанта пpиводит к увеличению паpаметpа (FM - FT)/FT медленной индукции флуоpеcценции лиcта. У обpаботанного ячменя наблюдалоcь увеличение уpожайноcти и оcновныx показателей cтpуктуpы уpожая

    Slow fluorescence induction and productivity of barley treated with a supercritical fluid extract of amaranth

    No full text
    Treatment of barley plants with a supercritical fluid extract of amaranth led to an increase in parameter (FM - FT)/FT of the leaf slow fluorescence induction curve. Barley treated with the extract showed higher productivity and better crop indices.ОРИГИНАЛЬНАЯ ВЕРСИЯ: МЕДЛЕННАЯ ИНДУКЦИЯ ФЛУОРЕСЦЕНЦИИ И ПРОДУКТИВНОСТЬ ЯЧМЕНЯ, ОБРАБОТАННОГО CВЕРХКРИТИЧЕСКИМ ФЛЮИДНЫМ ЭКСТРАКТОМ АМАРАНТА / Каpаваев В.А., Гунаp Л.Э., Мякиньков А.Г. [и др.] // Биофизика. 2012. Т. 57. № 4. С. 662-66

    Some luminescence characteristics of allocytoplasmic wheat hybrids

    No full text
    Comparative studies of thermoluminescence and slow fluorescence induction were carried out on leaves of allocytoplasmic hybrids and standard regionalized wheat (cultivar Zarya). There are differences in luminescence indices between these objects correlated to the thermoluminescence and slow fluorescence induction methods. These differences allow estimation of the functional activity of the photosynthetic system. All studied allocytoplasmic hybrids exceeded the standard wheat in both luminescence indices F-M/F-T(slow fluorescence induction) and S-A/S-tot (thermoluminescence) and productivity (height of seedlings, number of ears and grains, grain mass, etc.). The highest values of F-M/F-T and S-A/S-tot and the lowest value of S-C/S-tot were recorded in the allocytoplasmic hybrid Igen 3 x Mironovskaya 808, which is characterized by the highest productivity

    Investigation of statistical characteristics of interaction between the low-frequency oscillations in heart rate variability and peripheral microcirculation in healthy subjects and myocardial infarction patients

    No full text
    Objective. This study compares the statistical characteristics of interaction between 0.1 Hz oscillations in heart rate variability (HRV) and photoplethysmogram (PPG) in healthy subjects and myocardial infarction (Ml) patients. Material and methods. We studied 23 healthy subjects (20 men and 3 women aged 26±3 years) and 23 patients (12 men and 11 women aged 52±4 years) at about one month after Ml. The 10-minute signals of simultaneously recorded cardioin-tervalogram (CIG) and PPG were studied. We calculated the total percentage of phase synchronization between the studied 0.1 Hz oscillations and estimated the distribution functions of duration of synchronous and non-synchronous epochs, the variability of basic frequency of oscillations, and variance of phase noises in 0.1 Hz oscillations in HRV and PPG. Results. The total percentage of phase synchronization between 0.1 Hz oscillations is significantly greater in healthy subjects than in Ml patients (47±3% and 26±4%, respectively). Significant difference between these two groups in the distribution of duration of synchronous and non-synchronous epochs was not revealed. The Ml patients had greater variance between the basic frequencies of 0.1 Hz oscillations in HRV and PPG than healthy subjects. This phenomenon correlates with the increased level of phase noises in the records of Ml patients. Conclusion. The quality of synchronization between 0.1 Hz oscillations in HRV and PPG is associated with the strength of influence of external factors (noises) and variability of the basic frequency of these oscillations
    corecore