4,567 research outputs found
Recommended from our members
The Berkeley Contact Lens Extended Wear Study. Part I : Study design and conduct.
ObjectiveThe primary aim of the Berkeley Contact Lens Extended Wear Study (CLEWS) was to test the hypotheses that extended wear of rigid gas-permeable (RGP) contact lenses with greater oxygen permeability (Dk) reduces the incidence of contact lens-associated keratopathy (CLAK) and increases the survival rate in RGP extended wear (EW). In this article we describe the clinical trial design in detail, present the results of subject recruitment and retention, and provide the baseline demographic and ocular characteristics of the CLEWS subjects, whose data will be analyzed to address the study aims in a companion article.DesignA randomized, concurrently controlled clinical trial.InterventionSubjects were fitted with day wear (DW) high-Dk RGP lenses and then adapted to EW. Subjects who adapted to EW were then randomly assigned to either high- or medium-Dk RGP lenses for 12 months of 6-nights/week EW.Main outcome measuresSlit-lamp assessment and grading of 17 possible keratopathies, measurement of refractive error and corneal curvature, and symptoms. Follow-up data were collected every 3 months.ResultsFrom 545 subjects entering the DW adaptation phase, 201 adapted to EW and were randomly assigned to medium- or high-Dk lenses for 12 months of EW. The baseline characteristics of the two study groups were similar and did not differ from the 344 DW subjects who failed to adapt to EW. The distributions of oxygen transmissibility for the two study groups were disjoint, indicating that each group received distinctly different levels of hypoxia.ConclusionsWe show that CLEWS was appropriately designed to address the study hypotheses, was conducted with regard for the safety of the subjects, and adhered to rigorous protocols designed to control for bias and ensure the integrity of study data. We establish the internal validity of between-group statistical comparisons and characterize our study population to permit informed evaluation of the applicability of our results to the contact lens-wearing population in general
Recommended from our members
The Berkeley Contact Lens Extended Wear Study. Part II : Clinical results.
ObjectiveTo describe the principal clinical outcomes associated with 12 months use of rigid gas-permeable (RGP) extended wear contact lenses and address two primary study questions: (1) does extended wear (EW) of high oxygen transmissibility (Dk/t) RGP lenses reduce the incidence of ocular complications, and (2) does the wearing of high-Dk/t lenses reduce the rate of failure to maintain 6-night RGPEW over 12 months?DesignA randomized, concurrently controlled clinical trial.InterventionSubjects who adapted to EW with high Dk (oxygen permeability) RGP lenses were randomized to either high Dk or medium-Dk RGP lenses for 12 months of 6-night EW.Main outcome measuresContact lens-associated keratopathies (CLAK), changes in refractive error and corneal curvature, and survival in EW.ResultsTwo hundred one subjects were randomized to medium or high-Dk lenses for 12 months of EW. Sixty-two percent of the subjects in each group completed 12 months of EW; however, the probability of failure was significantly greater for the medium-Dk group. Although the risk of complications was similar for the two groups, the number of CLAK events that led to termination were 16 versus 5 for the medium-Dk and high-Dk groups, respectively. This suggests that the type of adverse response or the inability to reverse an adverse event was different for the group being exposed to the lower oxygen dose.ConclusionsThe level of oxygen available to the cornea has a significant impact on maintaining successful RGP extended contact lens wear, but not on the initial onset of CLAK. The number of clinical events leading to termination was substantially higher for the medium Dk group, which suggests that corneal hypoxia is an important factor in the development of CLAK. Although overnight contact lens wear should be recommended with caution and carefully monitored for early detection of ocular complications, it appears that high-Dk RGP lenses can be a safe and effective treatment for correction of refractive error for most individuals who can adapt to EW
A Suborbital Payload for Soft X-ray Spectroscopy of Extended Sources
We present a suborbital rocket payload capable of performing soft X-ray
spectroscopy on extended sources. The payload can reach resolutions of
~100(lambda/dlambda) over sources as large as 3.25 degrees in diameter in the
17-107 angstrom bandpass. This permits analysis of the overall energy balance
of nearby supernova remnants and the detailed nature of the diffuse soft X-ray
background. The main components of the instrument are: wire grid collimators,
off-plane grating arrays and gaseous electron multiplier detectors. This
payload is adaptable to longer duration orbital rockets given its comparatively
simple pointing and telemetry requirements and an abundance of potential
science targets.Comment: Accepted to Experimental Astronomy, 12 pages plus 1 table and 17
figure
LIGHT AND ELECTRON MICROSCOPIC STUDY OF SURFACES OF TEST-SPECIMENS TESTED IN WEAR APPARATUSES
Objective: Symptoms of acute retroviral syndrome (ARS) may be used to identify patients with acute HIV-1 infection who seek care. ARS symptoms in African adults differ by region. We assessed whether reporting of ARS was associated with HIV-1 subtype in a multicentre African cohort study representing countries with predominant HIV-1 subtypes A, C, and D. Methods: ARS symptoms were assessed in adults enrolling within 6 weeks after the estimated date of infection in an acute and early HIV-1 infection cohort study. HIV-1 subtype was determined by POL genotyping. We used log-binomial regression to compare ARS symptom prevalence among those with subtype A vs. C or D, adjusting for sex, time since enrolment, and enrolment viral load. Results: Among 183 volunteers ascertained within 6 weeks after estimated date of infection, 77 (42.0%) had subtype A, 83 (45.4%) subtype C, and 23 (12.6%) subtype D infection. Individuals with subtype A were 1.40 (95% confidence interval: 1.17, 1.68) times as likely as individuals with subtypes C or D to report any ARS symptoms; each individual symptom other than rash was also more prevalent in subtype A than in subtype C or D, with prevalence ratios ranging from 1.94 (1.40, 2.70) for headache to 4.92 (2.24, 10.78) for lymphadenopathy. Conclusion: Individuals with subtype A were significantly more likely than individuals with subtypes C or D to report any ARS symptoms. HIV-1 subtypes may help explain differences in ARS that have been observed across regions in Africa, and may impact the yield of symptom-based screening strategies for acute HIV infection detection
Indirect inguinal hernia masquerading as a Spigelian hernia
Inguinal hernia usually developed and descended into scrotum. The clinical presentation is inguinal or
inguino-scrotal swelling. Abdominal wall weakness as it is frequently seen in African tropical zones
produces often rare clinical case. We report a case of inguinal hernia presented as an abdominal wall swelling clinically suggestive of a
Spigelian hernia and discuss the mechanism
The NACA 63(3)-018 Benchmark
Within the IEA Wind TCP Task 39 co-operational framework,
aiming at consolidating knowledge on wind turbine noise for
quiet wind turbine technologies, a benchmark activity has been initiated to expand the available trailing-edge noise data base from the ongoing AIAA/CEAS BANC-Workshop series on Benchmark Problems for Airframe Noise Computations.
The goals behind this initiative are to create verified experimental data on trailing-edge noise sources and noise reduction devices (trailing-edge serrations) with applications for the wind turbine industry.
Several research facilities (including hybrid, closed and open wind tunnel facilities) are involved in a round robin test, covering a large set of Reynolds numbers and test conditions.
The current presentation wraps up the current status of the experimental program
Cognitive performance in relapsing remitting multiple sclerosis: A longitudinal study in daily practice using a brief computerized cognitive battery
<p>Abstract</p> <p>Background</p> <p>There is need for a cognitive test battery that can be easily used in clinical practice to detect or monitor cognitive performance in patients with multiple sclerosis (MS). In order to conduct, in this patient group, a preliminary investigation of the validity and utility of a brief computerized battery, the Cognitive Drug Research (CDR) battery, we longitudinally assessed cognition in patients with relapsing remitting (RR) MS.</p> <p>Methods</p> <p>Forty-three mildly disabled, clinically active RRMS patients were repeatedly assessed with the Digit Symbol Substitution Test (DSST), Paced Auditory Serial Addition Test (PASAT) and five composite scores derived from the CDR computerized cognitive test system (CDR System): Power of Attention, Continuity of Attention, Quality of Working Memory, Quality of Episodic Memory and Speed of Memory. The Multiple Sclerosis Functional Composite (MSFC) and Expanded Disability Status Scale (EDSS) measured disability.</p> <p>Results</p> <p>The composite scores from the CDR battery generally showed excellent test-retest reliability over the repeated assessments, though was low on occasions for the Quality of Working Memory and Quality of Episodic Memory measures. The CDR measures tended to be highly correlated with other measures of cognition (DSST and PASAT) and were also strongly related to disability (EDSS and MSFC). Baseline scores indicated large impairments to visual information processing speed and attention (DSST, Cohen's d 1.1; Power of Attention d 1.4 [reaction time on tasks of focussed and sustained attention]), and a moderate impairment both to sustained attention (Continuity of Attention d 0.6) and complex information processing speed (Speed of memory d 0.7 [reaction time on tasks of working and episodic Memory]), when compared to normative data derived from healthy volunteers enrolled in a series of separate, prior clinical trials. Working memory (Quality of Working Memory) and episodic memory (Quality of Episodic Memory) were unimpaired.</p> <p>Conclusions</p> <p>Preliminary validation of the CDR System indicated that for most, but not all measures psychometric properties were adequate and the measures were related to disability (EDSS and MSFC) and other measures of cognition.</p
FindFoci: a focus detection algorithm with automated parameter training that closely matches human assignments, reduces human inconsistencies and increases speed of analysis
Accurate and reproducible quantification of the accumulation of proteins into foci in cells is essential for data interpretation and for biological inferences. To improve reproducibility, much emphasis has been placed on the preparation of samples, but less attention has been given to reporting and standardizing the quantification of foci. The current standard to quantitate foci in open-source software is to manually determine a range of parameters based on the outcome of one or a few representative images and then apply the parameter combination to the analysis of a larger dataset. Here, we demonstrate the power and utility of using machine learning to train a new algorithm (FindFoci) to determine optimal parameters. FindFoci closely matches human assignments and allows rapid automated exploration of parameter space. Thus, individuals can train the algorithm to mirror their own assignments and then automate focus counting using the same parameters across a large number of images. Using the training algorithm to match human assignments of foci, we demonstrate that applying an optimal parameter combination from a single image is not broadly applicable to analysis of other images scored by the same experimenter or by other experimenters. Our analysis thus reveals wide variation in human assignment of foci and their quantification. To overcome this, we developed training on multiple images, which reduces the inconsistency of using a single or a few images to set parameters for focus detection. FindFoci is provided as an open-source plugin for ImageJ
- …