2,748 research outputs found
First Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory
We report on the first long-term application of squeezed vacuum states of
light to improve the shot-noise-limited sensitivity of a gravitational-wave
observatory. In particular, squeezed vacuum was applied to the German/British
detector GEO600 during a period of three months from June to August 2011, when
GEO600 was performing an observational run together with the French/Italian
Virgo detector. In a second period squeezing application continued for about 11
months from November 2011 to October 2012. During this time, squeezed vacuum
was applied for 90.2% (205.2 days total) of the time that science-quality data
was acquired with GEO600. Sensitivity increase from squeezed vacuum application
was observed broad-band above 400Hz. The time average of gain in sensitivity
was 26% (2.0dB), determined in the frequency band from 3.7kHz to 4.0kHz. This
corresponds to a factor of two increase in observed volume of the universe, for
sources in the kHz region (e.g. supernovae, magnetars). We introduce three new
techniques to enable stable long-term application of squeezed light, and show
that the glitch-rate of the detector did not increase from squeezing
application. Squeezed vacuum states of light have arrived as a permanent
application, capable of increasing the astrophysical reach of
gravitational-wave detectors.Comment: 4 pages, 4 figure
Optimal time-domain combination of the two calibrated output quadratures of GEO 600
GEO 600 is an interferometric gravitational wave detector with a 600 m arm-length and which uses a dual-recycled optical configuration to give enhanced sensitivity over certain frequencies in the detection band. Due to the dual-recycling, GEO 600 has two main output signals, both of which potentially contain gravitational wave signals. These two outputs are calibrated to strain using a time-domain method. In order to simplify the analysis of the GEO 600 data set, it is desirable to combine these two calibrated outputs to form a single strain signal that has optimal signal-to-noise ratio across the detection band. This paper describes a time-domain method for doing this combination. The method presented is similar to one developed for optimally combining the outputs of two colocated gravitational wave detectors. In the scheme presented in this paper, some simplifications are made to allow its implementation using time-domain methods
The upgrade of GEO600
The German / British gravitational wave detector GEO 600 is in the process of
being upgraded. The upgrading process of GEO 600, called GEO-HF, will
concentrate on the improvement of the sensitivity for high frequency signals
and the demonstration of advanced technologies. In the years 2009 to 2011 the
detector will undergo a series of upgrade steps, which are described in this
paper.Comment: 9 pages, Amaldi 8 conference contributio
Performance of a 1200m long suspended Fabry-Perot cavity
Using one arm of the Michelson interferometer and the power recycling mirror
of the interferometric gravitational wave detector GEO600, we created a
Fabry-Perot cavity with a length of 1200 m. The main purpose of this experiment
was to gather first experience with the main optics, its suspensions and the
corresponding control systems. The residual displacement of a main mirror is
about 150 nm rms. By stabilising the length of the 1200 m long cavity to the
pre-stabilised laser beam we achieved an error point frequency noise of 0.1
mHz/sqrt(Hz) at 100 Hz Fourier frequency. In addition we demonstrated the
reliable performance of all included subsystems by several 10-hour-periods of
continuous stable operation. Thus the full frequency stabilisation scheme for
GEO600 was successfully tested.Comment: Amaldi 4 (Perth 2001) conference proceedings, 10 pages, 8 figure
Thermal noise of folding mirrors
Current gravitational wave detectors rely on the use of Michelson interferometers. One crucial limitation of their sensitivity is the thermal noise of their optical components. Thus, for example fluctuational deformations of the mirror surface are probed by a laser beam being reflected from the mirrors at normal incidence. Thermal noise models are well evolved for that case but mainly restricted to single reflections. In this work we present the effect of two consecutive reflections under a non-normal incidence onto mirror thermal noise. This situation is inherent to detectors using a geometrical folding scheme such as GEO\,600. We revise in detail the conventional direct noise analysis scheme to the situation of non-normal incidence allowing for a modified weighting funtion of mirror fluctuations. An application of these results to the GEO\,600 folding mirror for Brownian, thermoelastic and thermorefractive noise yields an increase of displacement noise amplitude by 20\% for most noise processes. The amplitude of thermoelastic substrate noise is increased by a factor 4 due to the modified weighting function. Thus the consideration of the correct weighting scheme can drastically alter the noise predictions and demands special care in any thermal noise design process
Cost-benefit analysis for commissioning decisions in GEO600
Gravitational wave interferometers are complex instruments, requiring years
of commissioning to achieve the required sensitivities for the detection of
gravitational waves, of order 10^-21 in dimensionless detector strain, in the
tens of Hz to several kHz frequency band. Investigations carried out by the
GEO600 detector characterisation group have shown that detector
characterisation techniques are useful when planning for commissioning work. At
the time of writing, GEO600 is the only large scale laser interferometer
currently in operation running with a high duty factor, 70%, limited chiefly by
the time spent commissioning the detector. The number of observable
gravitational wave sources scales as the product of the volume of space to
which the detector is sensitive and the observation time, so the goal of
commissioning is to improve the detector sensitivity with the least possible
detector down time. We demonstrate a method for increasing the number of
sources observable by such a detector, by assessing the severity of
non-astrophysical noise contaminations to efficiently guide commissioning. This
method will be particularly useful in the early stages and during the initial
science runs of the aLIGO and adVirgo detectors, as they are brought up to
design performance.Comment: 17 pages, 17 figures, 2 table
Results from the first burst hardware injections performed on GEO600
GEO 600 is a 600 m arm-length, laser interferometric gravitational wave detector, located about 25 km from Hannover, Germany. Starting in November 2003, GEO 600 took part in a coincident data taking period with other detectors around the world. During this time, GEO 600 acquired three weeks of 'science quality' data. These data are currently being processed to search for gravitational wave signatures. One such search is that for burst gravitational waves. To investigate the performance of any burst-search codes used to analyse the data, burst-like signals were injected into the detector after the data taking run; this was done by differentially driving the end mirrors of the interferometer. In this paper, we report on how the first burst hardware injections were performed on GEO 600, the type of signals injected and the analysis of the data from the period of injections. Results from the analysis are also presented and discussed
Physical instrumental vetoes for gravitational-wave burst triggers
We present a robust strategy to \emph{veto} certain classes of instrumental
glitches that appear at the output of interferometric gravitational-wave (GW)
detectors.This veto method is `physical' in the sense that, in order to veto a
burst trigger, we make use of our knowledge of the coupling of different
detector subsystems to the main detector output. The main idea behind this
method is that the noise in an instrumental channel X can be \emph{transferred}
to the detector output (channel H) using the \emph{transfer function} from X to
H, provided the noise coupling is \emph{linear} and the transfer function is
\emph{unique}. If a non-stationarity in channel H is causally related to one in
channel X, the two have to be consistent with the transfer function. We
formulate two methods for testing the consistency between the burst triggers in
channel X and channel H. One method makes use of the \emph{null-stream}
constructed from channel H and the \emph{transferred} channel X, and the second
involves cross-correlating the two. We demonstrate the efficiency of the veto
by `injecting' instrumental glitches in the hardware of the GEO 600 detector.
The \emph{veto safety} is demonstrated by performing GW-like hardware
injections. We also show an example application of this method using 5 days of
data from the fifth science run of GEO 600. The method is found to have very
high veto efficiency with a very low accidental veto rate.Comment: Minor changes, To appear in Phys. Rev.
GEO 600 and the GEO-HF upgrade program: successes and challenges
The German-British laser-interferometric gravitational wave detector GEO 600
is in its 14th year of operation since its first lock in 2001. After GEO 600
participated in science runs with other first-generation detectors, a program
known as GEO-HF began in 2009. The goal was to improve the detector sensitivity
at high frequencies, around 1 kHz and above, with technologically advanced yet
minimally invasive upgrades. Simultaneously, the detector would record science
quality data in between commissioning activities. As of early 2014, all of the
planned upgrades have been carried out and sensitivity improvements of up to a
factor of four at the high-frequency end of the observation band have been
achieved. Besides science data collection, an experimental program is ongoing
with the goal to further improve the sensitivity and evaluate future detector
technologies. We summarize the results of the GEO-HF program to date and
discuss its successes and challenges
Photon pressure induced test mass deformation in gravitational-wave detectors
A widely used assumption within the gravitational-wave community has so far
been that a test mass acts like a rigid body for frequencies in the detection
band, i.e. for frequencies far below the first internal resonance. In this
article we demonstrate that localized forces, applied for example by a photon
pressure actuator, can result in a non-negligible elastic deformation of the
test masses. For a photon pressure actuator setup used in the gravitational
wave detector GEO600 we measured that this effect modifies the standard
response function by 10% at 1 kHz and about 100% at 2.5 kHz
- …