25 research outputs found

    Application of 4,5-diaminofluorescein to reliably measure nitric oxide released from endothelial cells in vitro

    Get PDF
    Here we describe in more depth the previously published application of the fluorescent probe 4,5-diaminofluorescein (DAF-2) in order to reliably measure low levels of nitric oxide (NO) as released from human endothelial cells in vitro. The used approach is based on the following considerations a) use low concentrations of DAF-2 (0.1 µM) in order to reduce the contribution of DAF-2 auto-fluorescence to the measured total fluorescence, and b) subtract the DAF-2 auto-fluorescence from the measured total fluorescence. The advantage of this method is the reliable quantification of NO in a biological system in the nanomolar range once thoroughly validated. Here we focus in addition to the previous publication (Leikert et al., FEBS Lett 2001, 506:131-134) on aspects of validation procedures as well as limitations and pitfalls of this method

    In-Orbit Performance of the GRACE Follow-on Laser Ranging Interferometer

    No full text
    The Laser Ranging Interferometer (LRI) instrument on the Gravity Recovery and Climate Experiment (GRACE) Follow-On mission has provided the first laser interferometric range measurements between remote spacecraft, separated by approximately 220 km. Autonomous controls that lock the laser frequency to a cavity reference and establish the 5 degree of freedom two-way laser link between remote spacecraft succeeded on the first attempt. Active beam pointing based on differential wavefront sensing compensates spacecraft attitude fluctuations. The LRI has operated continuously without breaks in phase tracking for more than 50 days, and has shown biased range measurements similar to the primary ranging instrument based on microwaves, but with much less noise at a level of 1 nm/Hz1\,{\rm nm}/\sqrt{\rm Hz} at Fourier frequencies above 100 mHz

    The BepiColombo Laser Altimeter

    Get PDF
    The BepiColombo Laser Altimeter (BELA) is the first European laser altimeter constructed for interplanetary flight. BELA uses a 50 mJ pulsed Nd:YAG laser operating at 10 Hz with a 20 cm aperture receiver to perform the ranging. The instrument also uses a digital approach for range detection and pulse analysis. The ranging accuracy is expected to be better than 2 metres and ∼20 cm in optimum conditions. With the given, only slightly elliptical, orbit, BELA should return a consistent data set for the most if not all of the planet. The instrument is required to function in an extreme environment with the thermal issues being particularly demanding. Novel solutions have been taken to resolve these issues. BELA is described in detail and its predicted performance outlined on the basis of pre-flight testing
    corecore