16 research outputs found

    Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Fine-needle aspiration biopsy (FNAB) of the breast is a minimally invasive yet maximally diagnostic method. However, the clinical use of FNAB has been questioned. The purpose of our study was to establish the overall value of FNAC in the diagnosis of breast lesions.</p> <p>Methods</p> <p>After a review and quality assessment of 46 studies, sensitivity, specificity and other measures of accuracy of FNAB for evaluating breast lesions were pooled using random-effects models. Summary receiver operating characteristic curves were used to summarize overall accuracy. The sensitivity and specificity for the studies data (included unsatisfactory samples) and underestimation rate of unsatisfactory samples were also calculated.</p> <p>Results</p> <p>The summary estimates for FNAB in diagnosis of breast carcinoma were as follows (unsatisfactory samples was temporarily exluded): sensitivity, 0.927 (95% confidence interval [CI], 0.921 to 0.933); specificity, 0.948 (95% CI, 0.943 to 0.952); positive likelihood ratio, 25.72 (95% CI, 17.35 to 28.13); negative likelihood ratio, 0.08 (95% CI, 0.06 to 0.11); diagnostic odds ratio, 429.73 (95% CI, 241.75 to 763.87); The pooled sensitivity and specificity for 11 studies, which reported unsatisfactory samples (unsatisfactory samples was considered to be positive in this classification) were 0.920 (95% CI, 0.906 to 0.933) and 0.768 (95% CI, 0.751 to 0.784) respectively. The pooled proportion of unsatisfactory samples that were subsequently upgraded to various grade cancers was 27.5% (95% CI, 0.221 to 0.296).</p> <p>Conclusions</p> <p>FNAB is an accurate biopsy for evaluating breast malignancy if rigorous criteria are used. With regard to unsatisfactory samples, futher invasive procedures are required in order to minimize the chance of a missed diagnosis of breast cancer.</p

    Mammography screening reduces rates of advanced and fatal breast cancers: Results in 549,091 women

    Get PDF
    Background It is of paramount importance to evaluate the impact of participation in organized mammography service screening independently from changes in breast cancer treatment. This can be done by measuring the incidence of fatal breast cancer, which is based on the date of diagnosis and not on the date of death.Methods Among 549,091 women, covering approximately 30% of the Swedish screening-eligible population, the authors calculated the incidence rates of 2473 breast cancers that were fatal within 10 years after diagnosis and the incidence rates of 9737 advanced breast cancers. Data regarding each breast cancer diagnosis and the cause and date of death of each breast cancer case were gathered from national Swedish registries. Tumor characteristics were collected from regional cancer centers. Aggregated data concerning invitation and participation were provided by Sectra Medical Systems AB. Incidence rates were analyzed using Poisson regression.Results Women who participated in mammography screening had a statistically significant 41% reduction in their risk of dying of breast cancer within 10 years (relative risk, 0.59; 95% CI, 0.51-0.68 [P < .001]) and a 25% reduction in the rate of advanced breast cancers (relative risk, 0.75; 95% CI, 0.66-0.84 [P < .001]).Conclusions Substantial reductions in the incidence rate of breast cancers that were fatal within 10 years after diagnosis and in the advanced breast cancer rate were found in this contemporaneous comparison of women participating versus those not participating in screening. These benefits appeared to be independent of recent changes in treatment regimens

    Early detection of breast cancer rectifies inequality of breast cancer outcomes

    Get PDF
    Objectives To explain apparent differences among mammography screening services in Sweden using individual data on participation in screening and with breast cancer-specific survival as an outcome.Methods We analysed breast cancer survival data from the Swedish Cancer Register on breast cancer cases from nine Swedish counties diagnosed in women eligible for screening. Data were available on 38,278 breast cancers diagnosed and 4312 breast cancer deaths. Survival to death from breast cancer was estimated using the Kaplan-Meier estimate, for all cases in each county, and separately for cases of women participating and not participating in their last invitation to screening. Formal statistical comparisons of survival were made using proportional hazards regression.Results All counties showed a reduction in the hazard of breast cancer death with participation in screening, but the reductions for individual counties varied substantially, ranging from 51% (95% confidence interval 46-55%) to 81% (95% confidence interval 74-85%). Survival rates in nonparticipating women ranged from 53% (95% confidence interval 40-65%) to 74% (95% confidence interval 72-77%), while the corresponding survival in women participating in screening varied from 80% (95% confidence interval 77-84%) to 86% (95% confidence interval 83-88%), a considerably narrower range.Conclusions Differences among counties in the effect of screening on breast cancer outcomes were mainly due to variation in survival in women not participating in screening. Screening conferred similarly high survival rates in all counties. This indicates that the performance of screening services was similar across counties and that detection and treatment of breast cancer in early-stage reduces inequalities in breast cancer outcome.</div

    A comprehensive tool for measuring mammographic density changes over time

    No full text
    10.1007/s10549-018-4690-5Breast Cancer Research and Treatment1692371-37

    Correlation of contrast-enhanced ultrasound kinetics with prognostic factors in invasive breast cancer

    No full text
    OBJECTIVES: To correlate contrast-enhanced ultrasound (CEUS) kinetic parameters with traditional and molecular prognostic factors in invasive breast cancer. METHODS: Seventy-five invasive breast cancers were evaluated with contrast harmonic imaging after the injection of a bolus dose of 2.4 ml sulphur hexafluoride microbubble contrast agent. The lognormal function was used for quantitative analysis of kinetic data. These parameters correlated with traditional prognostic factors (tumour size, histological type, tumour grade, axillary lymph node status) and immunohistochemical biomarkers (ER, PR and HER2 status). RESULTS: Statistically significant correlation was found between time-to-peak and tumour grade (P value = 0.023), PR status (P value = 0.042) and axillary node status (P value = 0.025). Wash-out ratio, measured at 21 s was significantly associated with ER status (P value = 0.042) and PR status (P value = 0.026). CONCLUSIONS: Invasive breast carcinomas exhibiting earlier peak enhancement and faster elimination of microbubble contrast agent at CEUS are found to be associated with established predictors of poor prognosis. KEY POINTS: * Contrast-enhanced ultrasound (CEUS) can potentially determine the aggressiveness of invasive breast cancers. * Early peak enhancement and accelerated wash-out at CEUS suggest poor prognosis. * CEUS kinetics are similar to that of DCE-MRI in assessing tumour aggressiveness

    Contrast-enhanced ultrasound using real-time contrast harmonic imaging in invasive breast cancer: comparison of enhancement dynamics with three different doses of contrast agent

    No full text
    Background: In the last few years new potential applications have been developed for contrast-enhanced ultrasound (CEUS) and the management of breast diseases, but there is still some debate concerning the optimal dose to evaluate breast lesions, especially as a diagnostic tool. Purpose: To compare different CEUS doses of injected contrast agent in order to establish an optimal dose for the diagnosis of invasive breast cancer. Material and Methods: In Group A we compared the bolus dose of 1.2 mL vs. 2.4 mL and in Group B we compared the bolus dose of 2.4 mL vs. 4.8 mL (26 and 25 invasive carcinomas, respectively). CEUS was performed in real-time contrast harmonic imaging (CHI) using a L9-3 MHz probe. All examinations were recorded in a contrast side/side imaging mode loop for 120 s. Wash-in and wash-out patterns of the contrast agent were analyzed with advanced US quantification software and kinetic curves were used for statistical analysis. Results: In Group B (2.4 mL vs. 4.8 mL), more and stronger correlation was found among kinetic parameters (area under the curve, P< 0.00001; lognormal model parameters, mu, P = 0.0007 and sigma, P< 0.0001; mean transit time, P< 0.0001; model-based wash-out ratios, W-21m, P = 0.0002; W-50m, P = 0.0001; time-to-peak, P = 0.005) as compared to Group A (1.2 mL vs. 2.4 mL). Conclusion: The optimal way to evaluate kinetic features of invasive breast tumors using real-time CEUS is with an injection of contrast agent of either 2.4 mL or 4.8 mL
    corecore