23 research outputs found

    Short-term outcome after total hip arthroplasty using dual-mobility cup: report from Lithuanian Arthroplasty Register

    Get PDF
    To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked FilesPURPOSE: The purpose of the study was to investigate how the use of dual-mobility cups (DMCs) affected the risk of revision due to dislocation as well as overall risk of revision compared with a conventional total hip arthroplasty (THA) system in the short term. METHODS: A total of 12,657 primary THAs were registered from the start of 2011 to the end of 2014. 620 THAs were with DMCs. For comparison, we included all registered THAs with Exeter cup and a cemented Exeter stem combined with 28-mm femoral head. Patients were followed up with respect to revision and/or death until 1 January 2016. For survival analysis, we used revision as an endpoint. Cox proportional hazards models were used to analyse the influence of various covariates (age, gender, surgical approach, THA model and pre-operative diagnosis). RESULTS: Of the 620 dual-mobility THAs and 2170 Exeter THAs, 100 had been revised. The overall unadjusted cumulative revision rate (CRR) for any reason of revision at five years after surgery was 3.9% in the dual-mobility group and 5.2% in the Exeter group. Cox regression analysis, adjusting for age, gender, THA type, surgical approach and pre-operative diagnosis, showed that the risk of revision was less in patients operated with DMCs and in patients having their operation for osteoarthritis. CONCLUSION: The DM implant had a lower short-term complication rate than a conventional well defined THA. Low dislocation rate suggests that it is a good choice for high risk patients

    Introduction of total knee arthroplasty in Lithuania: Results from the first 10 years

    Get PDF
    Background and purpose We have previously reported that the first 10 years of hip arthroplasty in Lithuania resulted in a higher cumulative revision rate than that observed in Sweden. We thus compared the corresponding results after introduaction of total knee replacement in Lithuania

    Bipolar hemiarthroplasty versus total hip arthroplasty in femoral neck fracture patients : results from Lithuanian Arthroplasty Register

    No full text
    Introduction: Elderly patients with displaced femoral neck fractures (FNF) are usually operated with arthroplasty but with various combinations of implants and approaches. Thus, the optimal treatment is still controversial. We aimed to compare the results between the cemented bipolar hemiarthroplasty (HA) and total hip arthroplasty (THA) patients operated for FNF regarding revision rate at 1 year postoperatively. Methods: The data were derived from the Lithuanian Arthroplasty Register. We included patients operated with cemented bipolar HA and compared them to the most frequently used cemented THA with 28-mm head during 2011–2016. For survival analysis, we used both revision for all reasons and for dislocations as an endpoint. Cox proportional hazards models were used to analyse the influence of covariates (age groups, gender, surgical approaches and arthroplasty groups). Results: There were 1177 bipolar HA and 514 THA included in our study. 26 (2.2%) revisions had occurred among the bipolar HAs as compared to 25 (4.9%) among the THAs 1 year after surgery. The main reason for revision was dislocation. The unadjusted cumulative revision rate for any reason at 1 year after surgery was 2.4% for the bipolar HA group and 5.1% for the THA group (p = 0.0054). Cox regression analysis showed that the use of bipolar HA, anterolateral approach and younger age groups had lower risk of revision for all reasons. Conclusion: Bipolar HA and anterolateral approach had a significantly lower overall 1-year risk of revision in femoral neck fracture patients as compared to THA with 28-mm femoral heads

    Dynamics of femoral bone remodelling in well fixed total hip arthroplasty. A 20-year follow-up of 20 hips.

    No full text
    The aim of our study was to investigate the dynamics of cortical thinning around well fixed cemented Muller straight stems without osteolysis at different time periods during long term follow-up. We investigated patients operated on for osteoarthritis with a cemented Muller straight stem, all with more than 15 years follow-up and no radiological signs of osteolysis. Cortical thinning in 20 THA hips (19 patients) followed for a mean of 20 (16 to 22) years was measured medially and laterally at six levels from the first postoperative, five, 10 years and the last follow-up x-rays. Sixty percent of observed cortical thinning occurred during the first five postoperative years, which was more evident proximally. We conclude that significantly greater cortical bone loss occurs around cemented Muller straight stems during the first five years, than is seen subsequently. We feel that this is a non-pathological process mainly related to the Muller straight stem

    Long-Term Femoral Bone Remodeling After Cemented Hip Arthroplasty With the Müller Straight Stem in the Operated and Nonoperated Femora.

    No full text
    We investigated the cortical bone changes in 35 patients with total hip arthroplasty operated on only for osteoarthritis with more than 10 years of follow-up and with nonrevised femoral components and without radiologic signs of loosening. The mean follow-up was 16 ± 5 years. The thicknesses of femoral cortices were measured medially and laterally at 6 levels from the first postoperative and the last follow-up x-rays. A comparison with 10 patients who had a nonoperated contralateral hip was performed. We found a significant decrease in cortical thicknesses in total hip arthroplasty. The cortical thinning was significant at all periprosthetic levels but less expressed distally. Prosthetic femora were associated with greater cortical thinning as compared with the contralateral nonoperated femora, exceeding that caused by natural aging

    Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations : five year results from Lithuanian arthroplasty register

    No full text
    Purpose: Recently, there has been increasing interest in the use of dual mobility systems in the treatment of hip instability. The aim of this study was to investigate the re-revision rate of dual mobility cup compared to different surgical concepts when used for first-time hip revisions due to recurrent dislocations. Methods: The data were derived from the Lithuanian Arthroplasty Register. For survival analysis, we used both re-revision for all reasons and for dislocations as an end-point. Cox proportional hazards models were used to analyze the influence of various covariates (age, gender, and implant concept). Results: A total of 1388 revisions were recorded from 2011 to 2015, of which 362 were performed due to recurrent dislocation. Of the revisions, 247 were performed using dual mobility cups, while 115 were performed using a variety of other surgical constructs including constrained acetabular cups, conventional cups, femoral head exchanges, stem exchanges or anti-luxation rings. There were 27 re-revisions of which 15 were for additional dislocations. There were only 2% re-revisions due to dislocation with dual mobility vs 9% when using other surgical constructs. Cox regression adjusting for age and gender showed that in the short-term, dual mobility cup had a lower risk of revision due to dislocation as well as for all reasons compared to the other surgical constructs. Conclusion: In revision of total hip arthroplasties for dislocation, significantly lower short-term re-revision rate was observed for patients revised with dual mobility cup

    The analysis of posterior soft tissue repair durability after total hip arthroplasty in primary osteoarthritis patients

    No full text
    Background and purpose: The posterior soft tissue repair is 1 of the preventing factors for dislocation after total hip arthroplasty (THA). The aim of our study was to analyse THA patients with posterior soft tissue repair in terms of suture durability, time of suture failure and correlate the changes in leg length and offset postoperatively to suture durability. Methods: A total of 37 consecutive THA patients operated for osteoarthritis were included in the study. The posterior repair included reattaching the piriformis, conjoined tendons and posterior capsule to the greater trochanter through 2, 2 mm drill holes with 2 grasping stitches. A metal indicator wire was stitched into the piriformis tendon at distance of 1 cm from the greater trochanter after the prosthesis had been implanted and the joint reduced. Anteroposterior radiographs were taken immediately after the patients returned from the operating theatre to the intensive care unit, the next day after mobilisation, and at the 5th day of stay and at 3 months postoperatively. Results: Out of 37 THA hips, 6 (16%) had failed immediately after surgery, 25 (68%) at the 1st postoperative day after mobilisation, 2 (5%) at the 5th postoperative day, and 1 (3%) repairs had failed at 3 months after THA. In the remaining 3 hips no failure occurred. Interpretation: We conclude that posterior soft tissue repair in THA often fails and suggest that new posterior soft tissue repair methods be developed

    Moderate varus/valgus malalignment after total knee arthroplasty has little effect on knee function or muscle strength 91 patients assessed after 1 year

    No full text
    Background and purpose - Postoperative muscle strength and component alignment are important factors affecting functional results after total knee arthroplasty (TKA). We are not aware of any studies that have investigated the relationship between them. We therefore investigated whether coronal malalignment of the mechanical axis and/or of individual implant components would affect knee muscle strength and function 1 year after TKA surgery. Patients and methods - We included 120 consecutive osteoarthritis (OA) patients admitted for TKA. Preoperative active range of motion (ROM) of the knee, patient age, sex, and BMI were recorded and the Knee Society score (KSS) and knee joint extensor/flexor muscle strength were assessed. At 1-year follow-up, the mechanical and coronal component alignment was measured from a postoperative long standing radiograph, and ROM, KSS, and muscle strength measurements were taken in 91 patients. Functional outcome and muscle strength measurements were compared between normally aligned and malaligned TKA groups. Results - 29 of 91 TKAs were malaligned, i.e. they deviated more than 3 degrees from the neutral mechanical axis. 18 femoral components and 15 tibial components were malaligned. Before surgery, the malaligned and normally aligned groups were similar regarding sex distribution, BMI, ROM, KSS, and muscle strength. At the 1-year follow-up, the differences between the groups regarding knee joint function and muscle strength were small, not statistically significant, and barely clinically relevant. Interpretation - Moderate varus/valgus malalignment of the mechanical axis or of individual components has no relevant clinical effect on function or muscle strength 1 year after TKA surgery

    Measuring long radiographs affects the positioning of femoral components in total knee arthroplasty: a randomized controlled trial.

    No full text
    To access publisher's full text version of this article click on the hyperlink belowINTRODUCTION: The aim of this study was to investigate if preoperative measurements of the femoral valgus angle (FVA) affected the mechanical alignment, individual component positions and clinical outcome in total knee arthroplasty (TKA). METHODS: 120 patients were randomized into two groups. In one group (control), a fixed FVA for the intramedullary femoral guide was set at 7°, whereas in the other group (measured) FVA was measured preoperatively on long hip-knee-ankle radiographs, and the angle for the distal femoral cut was set accordingly. Preoperatively and 1 year after TKA, range of motion (ROM) and Knee Society Score (KSS) were assessed. Postoperatively, the coronal alignments of the components and the mechanical alignment were measured comparing the rate of outliers which deviated more than 3° from the neutral mechanical axis. RESULTS: 104 patients remained for the radiological analysis (52 in each group). There were no significant differences either in the mean preoperative or postoperative mechanical alignment, or femoral or tibial component alignment; also, there were no differences in the number of postoperative mechanical axis or tibial component alignment outliers. However, the number of femoral component alignment outliers was significantly higher in the control group. 97 patients were available for clinical outcome analysis. Preoperatively, the groups did not differ significantly with respect to KSS or ROM. The postoperative ROM and KSS functional subscale scores were similar between the groups. However, there was slightly but significantly better postoperative KSS objective subscale score in the measured group. CONCLUSIONS: Preoperative FVA measurement and following femoral distal cut adjustments did not affect overall leg alignment postoperatively, while positioning of femoral component was improved together with minor improvements in objective KSS subscale scores.Research Council of Lithuani

    Choice of approach, but not femoral head size, affects revision rate due to dislocations in THA after femoral neck fracture: results from the Lithuanian Arthroplasty Register

    No full text
    Purpose Hip dislocation after arthroplasty for femoral neck fractures (FNF) remains a serious complication. The aim of our study was to investigate FNF patients treated with THA, with a special focus of comparing the effect of surgical approach and femoral head size on the risk of revision for dislocation. Methods Data were derived from the Lithuanian Arthroplasty Register, and we calculated the cumulative revision rates after surgery. For survival analysis, we used revision due to dislocation as an end-point. Cox proportional hazards models were used to analyse the influence of various covariates (age, gender, femoral head size, surgical approach). Results A total of 8,813 primary THAs were registered from 1 January 2011 to 31 December 2013, of which 1,412 were due to FNF: 899 involved 28-mm femoral heads and the remaining 513 received 32-mm heads. The posterior approach was used in 1,156 cases and the anterolateral approach in 256.. At the end of the follow-up period, 74 hips had been revised for recurrent dislocation. Cox regression adjusting for age, gender and head size showed that the posterior approach had 2.3-times [95% confidence interval (CI): 1.0-5.0, p = 0.04] greater risk of revision for dislocation Conclusions We conclude that in order to reduce the early dislocation rate in FNF patients treated with THA, it is more effective to use the anterolateral approach than it is to select a femoral head size of 32 mm instead of 28 mm
    corecore