223 research outputs found

    Effects of optical beam angle on quantitative optical coherence tomography (OCT) in normal and surface degenerated bovine articular cartilage

    Get PDF
    2010-2011 > Academic research: refereed > Publication in refereed journalAccepted ManuscriptPublishe

    Depth-wise progression of osteoarthritis in human articular cartilage: investigation of composition, structure and biomechanics

    Get PDF
    SummaryObjectiveOsteoarthritis (OA) is characterized by the changes in structure and composition of articular cartilage. However, it is not fully known, what is the depth-wise change in two major components of the cartilage solid matrix, i.e., collagen and proteoglycans (PGs), during OA progression. Further, it is unknown how the depth-wise changes affect local tissue strains during compression. Our aim was to address these issues.MethodsData from the previous microscopic and biochemical measurements of the collagen content, distribution and orientation, PG content and distribution, water content and histological grade of normal and degenerated human patellar articular cartilage (n=73) were reanalyzed in a depth-wise manner. Using this information, a composition-based finite element (FE) model was used to estimate tissue function solely based on its composition and structure.ResultsThe orientation angle of collagen fibrils in the superficial zone of cartilage was significantly less parallel to the surface (P<0.05) in samples with early degeneration than in healthy samples. Similarly, PG content was reduced in the superficial zone in early OA (P<0.05). However, collagen content decreased significantly only at the advanced stage of OA (P<0.05). The composition-based FE model showed that under a constant stress, local tissue strains increased as OA progressed.ConclusionFor the first time, depth-wise point-by-point statistical comparisons of structure and composition of human articular cartilage were conducted. The present results indicated that early OA is primarily characterized by the changes in collagen orientation and PG content in the superficial zone, while collagen content does not change until OA has progressed to its late stage. Our simulation results suggest that impact loads in OA joint could create a risk for tissue failure and cell death

    Evaluation of composition and mineral structure of callus tissue in rat femoral fracture.

    Get PDF
    ABSTRACT. Callus formation is a critical step for successful fracture healing. Little is known about the molecular composition and mineral structure of the newly formed tissue in the callus. The aim was to evaluate the feasibility of small angle x-ray scattering (SAXS) to assess mineral structure of callus and cortical bone and if it could provide complementary information with the compositional analyses from Fourier transform infrared (FTIR) microspectroscopy. Femurs of 12 male Sprague-Dawley rats at 9 weeks of age were fractured and fixed with an intramedullary 1.1 mm K-wire. Fractures were treated with the combinations of bone morphogenetic protein-7 and/or zoledronate. Rats were sacrificed after 6 weeks and both femurs were prepared for FTIR and SAXS analysis. Significant differences were found in the molecular composition and mineral structure between the fracture callus, fracture cortex, and control cortex. The degree of mineralization, collagen maturity, and degree of orientation of the mineral plates were lower in the callus tissue than in the cortices. The results indicate the feasibility of SAXS in the investigation of mineral structure of bone fracture callus and provide complementary information with the composition analyzed with FTIR. Moreover, this study contributes to the limited FTIR and SAXS data in the field

    In Vivo Evaluation of the Potential of High-Frequency Ultrasound for Arthroscopic Examination of the Shoulder Joint

    Get PDF
    Objective. Accurate arthroscopic evaluation of cartilage lesions could significantly improve the outcome of repair surgery. In this study, we investigated for the first time the potential of intra-articular ultrasound as an arthroscopic tool for grading cartilage defects in the human shoulder joint in vivo and compared the outcome to results from arthroscopic evaluation and magnetic resonance imaging findings. Design. A total of 26 sites from 9 patients undergoing routine shoulder arthroscopy were quantitatively evaluated with a clinical intravascular (40MHz) ultrasound imaging system, using the regular arthroscopy portals. Reflection coefficient (R), integrated reflection coefficient (IRC), apparent integrated backscattering (AIB), and ultrasound roughness index (URI) were calculated, and high-resolution ultrasound images were obtained per site. Each site was visually graded according to the International Cartilage Repair Society (ICRS) system. "Ultrasound scores" corresponding to the ICRS system were determined from the ultrasound images. Magnetic resonance imaging was conducted and cartilage integrity at each site was classified into 5 grades (0 = normal, 4 = severely abnormal) by a radiologist. Results. R and IRC were lower at sites with damaged cartilage surface (P = 0.033 and P = 0.043, respectively) and correlated with arthroscopic ICRS grades (r (s) = -0.444, P = 0.023 and r (s) = -0.426, P = 0.03, respectively). Arthroscopic ICRS grades and ultrasound scores were significantly correlated (rs = 0.472, P = 0.015), but no significant correlation was found between magnetic resonance imaging data and other parameters. Conclusion. The results suggest that ultrasound arthroscopy could facilitate quantitative clinical appraisal of articular cartilage integrity in the shoulder joint and provide information on cartilage lesion depth and severity for quantitative diagnostics in surgery.Peer reviewe

    Cross-Calibration of GE Healthcare Lunar Prodigy and iDXA Dual-Energy X-Ray Densitometers for Bone Mineral Measurements

    Get PDF
    In long-term prospective studies, dual-energy X-ray absorptiometry (DXA) devices need to be inevitably changed. It is essential to assess whether systematic differences will exist between measurements with the new and old device. A group of female volunteers (21–72 years) underwent anteroposterior lumbar spine L2–L4 (n=72), proximal femur (n=72), and total body (n=62) measurements with the Prodigy and the iDXA scanners at the same visit. The bone mineral density (BMD) measurements with these two scanners showed a high linear association at all tested sites (r=0.962–0.995; p<0.0001). The average iDXA BMD values were 1.5%, 0.5%, and 0.9% higher than those of Prodigy for lumbar spine (L2–L4) (p<0.0001), femoral neck (p=0.048), and total hip (p<0.0001), respectively. Total body BMD values measured with the iDXA were −1.3% lower (p<0.0001) than those measured with the Prodigy. For total body, lumbar spine, and femoral neck, the BMD differences as measured with these two devices were independent of subject height and weight. Linear correction equations were developed to ensure comparability of BMD measurements obtained with both DXA scanners. Importantly, use of equations from previous studies would have increased the discrepancy between these particular DXA scanners, especially at hip and at spine

    Fourier Transform Infrared Spectroscopic Imaging and Multivariate Regression for Prediction of Proteoglycan Content of Articular Cartilage

    Get PDF
    Fourier Transform Infrared (FT-IR) spectroscopic imaging has been earlier applied for the spatial estimation of the collagen and the proteoglycan (PG) contents of articular cartilage (AC). However, earlier studies have been limited to the use of univariate analysis techniques. Current analysis methods lack the needed specificity for collagen and PGs. The aim of the present study was to evaluate the suitability of partial least squares regression (PLSR) and principal component regression (PCR) methods for the analysis of the PG content of AC. Multivariate regression models were compared with earlier used univariate methods and tested with a sample material consisting of healthy and enzymatically degraded steer AC. Chondroitinase ABC enzyme was used to increase the variation in PG content levels as compared to intact AC. Digital densitometric measurements of Safranin O –stained sections provided the reference for PG content. The results showed that multivariate regression models predict PG content of AC significantly better than earlier used absorbance spectrum (i.e. the area of carbohydrate region with or without amide I normalization) or second derivative spectrum univariate parameters. Increased molecular specificity favours the use of multivariate regression models, but they require more knowledge of chemometric analysis and extended laboratory resources for gathering reference data for establishing the models. When true molecular specificity is required, the multivariate models should be used

    Intravascular Ultrasound (IVUS): A Potential Arthroscopic Tool for Quantitative Assessment of Articular Cartilage

    Get PDF
    Conventional ultrasound examination of the articular cartilage performed externally on the body surface around the joint has limited accuracy due to the inadequacy in frequency used. In contrast to this, minimally invasive arthroscopy-based ultrasound with adequately high frequency may be a better alternative to assess the cartilage. Up to date, no special ultrasound transducer for imaging the cartilage in arthroscopic use has been designed. In this study, we introduced the intravascular ultrasound (IVUS) for this purpose. An IVUS system with a catheter-based probe (Ø ≈ 1mm) was used to measure the thickness and surface acoustical reflection of the bovine patellar articular cartilage in vitro before and after degeneration induced by enzyme treatments. Similar measurement was performed using another high frequency ultrasound system (Vevo) with a probe of much larger size and the results were compared between the two systems. The thickness measured using IVUS was highly correlated (r = 0.985, p < 0.001) with that obtained by Vevo. Thickness and surface reflection amplitude measured using IVUS on the enzymatically digested articular cartilage showed changes similar to those obtained by Vevo, which were expectedly consistent with previous investigations. IVUS can be potentially used for the quantitative assessment of articular cartilage, with its ready-to-use arthroscopic feature
    corecore