118 research outputs found

    Large-bore Vascular Closure: New Devices and Techniques

    Get PDF
    Endovascular aneurysm repair, transcatheter aortic valve implantation and percutaneous mechanical circulatory support systems have become valuable alternatives to conventional surgery and even preferred strategies for a wide array of clinical entities. Their adoption in everyday practice is growing. These procedures require large-bore access into the femoral artery. Their use is thus associated with clinically significant vascular bleeding complications. Meticulous access site management is crucial for safe implementation of large-bore technologies and includes accurate puncture technique and reliable percutaneous closure devices. This article reviews different strategies for obtaining femoral access and contemporary percutaneous closure technologies

    Follow-up of internal mammary artery stent with 64-slice CT

    Get PDF
    We present a case of 81-year-old woman complaining chest pain after minimal efforts who underwent multiple coronary artery bypass grafts (CABGs) during the last 15 years. A significant in-stent re-stenosis was found at ostium of left internal mammary artery (LIMA). A non-invasive CT coronary angiography (CT-CA) was performed after 6-month follow-up. CT-CA is a reliable non-invasive technique for the follow-up of stents in coronary artery bypass grafts

    Procedural Performance of Ultrathin, Biodegradable Polymer-Coated Stents Versus Durable Polymer-Coated Stents Based on Intracoronary Imaging

    Get PDF
    OBJECTIVE: Thinner stent struts might lead to a higher risk of recoil and subsequently a smaller minimal stent area (MSA), which is known to be the strongest predictor of stent failure. We compared procedural performance between an ultrathin-strut biodegradable-polymer sirolimus-eluting stent (BP-SES) and a durable-polymer zotarolimus-eluting stent (DP-ZES) using intracoronary imaging.METHODS: A consecutive cohort of patients underwent percutaneous coronary intervention (PCI) with either BP-SES or DP-ZES in a pseudorandomized fashion between July 2018 and October 2019. In the present subanalysis, we included cases in which post-PCI imaging with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) was performed. The primary endpoint of the study was MSA. Secondary endpoints included percentage stent expansion and presence of residual edge disease, malapposition, tissue protrusion, submedial edge dissections, or edge hematoma.RESULTS: A total of 141 treated lesions (78 BP-SES and 63 DP-ZES) in 127 patients were analyzed. Median age was 69.3 years (interquartile range [IQR], 57.3-75.6) and 74.0% of patients were male. All baseline and procedural characteristics were comparable between both groups. Median MSA was 5.80 mm² (IQR, 4.40-7.24) for BP-SES and 6.35 mm² (IQR, 4.76-8.31) for DP-ZES (P=.15). No significant differences in stent expansion, residual edge disease and presence of malapposition, tissue protrusion, submedial edge dissections, or edge hematomas were found. Stent diameter and stent length were found to be independent predictors of MSA.CONCLUSIONS: No significant differences in MSA were found between lesions treated with BP-SES vs DP-ZES. BP-SES and DP-ZES were comparable in terms of procedural performance.</p

    Procedural Performance of Ultrathin, Biodegradable Polymer-Coated Stents Versus Durable Polymer-Coated Stents Based on Intracoronary Imaging

    Get PDF
    OBJECTIVE: Thinner stent struts might lead to a higher risk of recoil and subsequently a smaller minimal stent area (MSA), which is known to be the strongest predictor of stent failure. We compared procedural performance between an ultrathin-strut biodegradable-polymer sirolimus-eluting stent (BP-SES) and a durable-polymer zotarolimus-eluting stent (DP-ZES) using intracoronary imaging.METHODS: A consecutive cohort of patients underwent percutaneous coronary intervention (PCI) with either BP-SES or DP-ZES in a pseudorandomized fashion between July 2018 and October 2019. In the present subanalysis, we included cases in which post-PCI imaging with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) was performed. The primary endpoint of the study was MSA. Secondary endpoints included percentage stent expansion and presence of residual edge disease, malapposition, tissue protrusion, submedial edge dissections, or edge hematoma.RESULTS: A total of 141 treated lesions (78 BP-SES and 63 DP-ZES) in 127 patients were analyzed. Median age was 69.3 years (interquartile range [IQR], 57.3-75.6) and 74.0% of patients were male. All baseline and procedural characteristics were comparable between both groups. Median MSA was 5.80 mm² (IQR, 4.40-7.24) for BP-SES and 6.35 mm² (IQR, 4.76-8.31) for DP-ZES (P=.15). No significant differences in stent expansion, residual edge disease and presence of malapposition, tissue protrusion, submedial edge dissections, or edge hematomas were found. Stent diameter and stent length were found to be independent predictors of MSA.CONCLUSIONS: No significant differences in MSA were found between lesions treated with BP-SES vs DP-ZES. BP-SES and DP-ZES were comparable in terms of procedural performance.</p

    Sirolimus-Eluting Versus Paclitaxel-Eluting Stent Implantation for the Percutaneous Treatment of Left Main Coronary Artery Disease A Combined RESEARCH and T-SEARCH Long-Term Analysis

    Get PDF
    ObjectivesThe purpose of this study was to investigate the long-term clinical and angiographic profile of sirolimus-eluting stent (SES) versus paclitaxel-eluting stent (PES) in patients undergoing percutaneous intervention for left main (LM) coronary disease.BackgroundThe long-term clinical and angiographic impact of SES as opposed to PES implantation in this subset of patients is unknown.MethodsFrom April 2002 to March 2004, 110 patients underwent percutaneous intervention for LM stenosis at our institution; 55 patients were treated with SES and 55 with PES. The two groups were well balanced for all baseline characteristics.ResultsAt a median follow-up of 660 days (range 428 to 885), the cumulative incidence of major adverse cardiovascular events was similar (25% in the SES group vs. 29%, in the PES group; hazard ratio 0.88 [95% confidence interval 0.43 to 1.82]; p = 0.74), reflecting similarities in both the composite death/myocardial infarction (16% in the SES group and 18% in the PES group) and target vessel revascularization (9% in the SES group and 11% in the PES group). Angiographic in-stent late loss (mm), evaluated in 73% of the SES group and in 77% of the PES group, was 0.32 ± 74 in the main and 0.36 ± 0.59 in the side branch in the SES group vs. 0.46 ± 0.57 (p = 0.36) and 0.52 ± 0.42 (p = 0.41) in the PES group, respectively.ConclusionsIn consecutive patients undergoing percutaneous LM intervention, PES may perform closely to SES both in terms of angiographic and long-term clinical outcome
    • …
    corecore