231 research outputs found

    Computer-assisted versus non-computer-assisted preoperative planning of corrective osteotomy for extra-articular distal radius malunions: a randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Malunion is the most common complication of distal radius fracture. It has previously been demonstrated that there is a correlation between the quality of anatomical correction and overall wrist function. However, surgical correction can be difficult because of the often complex anatomy associated with this condition. Computer assisted surgical planning, combined with patient-specific surgical guides, has the potential to improve pre-operative understanding of patient anatomy as well as intra-operative accuracy. For patients with malunion of the distal radius fracture, this technology could significantly improve clinical outcomes that largely depend on the quality of restoration of normal anatomy. Therefore, the objective of this study is to compare patient outcomes after corrective osteotomy for distal radius malunion with and without preoperative computer-assisted planning and peri-operative patient-specific surgical guides.</p> <p>Methods/Design</p> <p>This study is a multi-center randomized controlled trial of conventional planning versus computer-assisted planning for surgical correction of distal radius malunion. Adult patients with extra-articular malunion of the distal radius will be invited to enroll in our study. After providing informed consent, subjects will be randomized to two groups: one group will receive corrective surgery with conventional preoperative planning, while the other will receive corrective surgery with computer-assisted pre-operative planning and peri-operative patient specific surgical guides. In the computer-assisted planning group, a CT scan of the affected forearm as well as the normal, contralateral forearm will be obtained. The images will be used to construct a 3D anatomical model of the defect and patient-specific surgical guides will be manufactured. Outcome will be measured by DASH and PRWE scores, grip strength, radiographic measurements, and patient satisfaction at 3, 6, and 12 months postoperatively.</p> <p>Discussion</p> <p>Computer-assisted surgical planning, combined with patient-specific surgical guides, is a powerful new technology that has the potential to improve the accuracy and consistency of orthopaedic surgery. To date, the role of this technology in upper extremity surgery has not been adequately investigated, and it is unclear whether its use provides any significant clinical benefit over traditional preoperative imaging protocols. Our study will represent the first randomized controlled trial investigating the use of computer assisted surgery in corrective osteotomy for distal radius malunions.</p> <p>Trial registration</p> <p>NCT01193010</p

    Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the face of costly fixation hardware with varying performance for treatment of distal humeral fractures, a novel technique (U-Frame) is proposed using conventional implants in a 180° plate arrangement. In this in-vitro study the biomechanical stability of this method was compared with the established technique which utilizes angular stable locking compression plates (LCP) in a 90° configuration.</p> <p>Methods</p> <p>An unstable distal 3-part fracture (AO 13-C2.3) was created in eight pairs of human cadaveric humeri. All bone pairs were operated with either the "Frame" technique, where two parallel plates are distally interconnected, or with the LCP technique. The specimens were cyclically loaded in simulated flexion and extension of the arm until failure of the construct occurred. Motion of all fragments was tracked by means of optical motion capturing. Construct stiffness and cycles to failure were identified for all specimens.</p> <p>Results</p> <p>Compared to the LCP constructs, the "Frame" technique revealed significant higher construct stiffness in extension of the arm (P = 0.01). The stiffness in flexion was not significantly different (P = 0.16). Number of cycles to failure was found significantly larger for the "Frame" technique (P = 0.01).</p> <p>Conclusions</p> <p>In an in-vitro context the proposed method offers enhanced biomechanical stability and at the same time significantly reduces implant costs.</p

    Septic thrombophlebitis with acute osteomyelitis in adolescent children: a report of two cases and review of the literature

    Get PDF
    The triad of acute osteomyelitis, deep venous thrombophlebitis, and septic pulmonary embolism is a rare, but life-threatening syndrome in children that requires prompt recognition and treatment. We report two cases of acute osteomyelitis complicated by septic thrombophlebitis and pulmonary emboli. Both patients required operative drainage to remove the septic focus. Recognition of any one component of the triad should prompt a search for the other associated disorders. Aggressive management with early antibiotic administration, anticoagulation, and surgical debridement can be life saving

    Anterior-inferior plating of middle-third fractures of the clavicle

    Get PDF
    © The Author(s) 2009. This article is published with open access at Springerlink.com Introduction Various techniques have been reported for the treatment of middle-third clavicle (collar bone) fractures. This prospective study was conducted to evaluate the results of anterior-inferior plating using a 3.5-mm reconstruction plate for the treatment of middle-third clavicle fractures

    Relationship between distal radius fracture malunion and arm-related disability: A prospective population-based cohort study with 1-year follow-up

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Distal radius fracture is a common injury and may result in substantial dysfunction and pain. The purpose was to investigate the relationship between distal radius fracture malunion and arm-related disability.</p> <p>Methods</p> <p>The prospective population-based cohort study included 143 consecutive patients above 18 years with an acute distal radius fracture treated with closed reduction and either cast (55 patients) or external and/or percutaneous pin fixation (88 patients). The patients were evaluated with the disabilities of the arm, shoulder and hand (DASH) questionnaire at baseline (concerning disabilities before fracture) and one year after fracture. The 1-year follow-up included the SF-12 health status questionnaire and clinical and radiographic examinations. Patients were classified into three hypothesized severity categories based on fracture malunion; no malunion, malunion involving either dorsal tilt (>10 degrees) or ulnar variance (≥1 mm), and combined malunion involving both dorsal tilt and ulnar variance. Multivariate regression analyses were performed to determine the relationship between the 1-year DASH score and malunion and the relative risk (RR) of obtaining DASH score ≥15 and the number needed to harm (NNH) were calculated.</p> <p>Results</p> <p>The mean DASH score at one year after fracture was significantly higher by a minimum of 10 points with each malunion severity category. The RR for persistent disability was 2.5 if the fracture healed with malunion involving either dorsal tilt or ulnar variance and 3.7 if the fracture healed with combined malunion. The NNH was 2.5 (95% CI 1.8-5.4). Malunion had a statistically significant relationship with worse SF-12 score (physical health) and grip strength.</p> <p>Conclusion</p> <p>Malunion after distal radius fracture was associated with higher arm-related disability regardless of age.</p
    corecore