113 research outputs found

    Sex discrepancies in pathophysiology, presentation, treatment, and outcomes of severe aortic stenosis

    Get PDF
    This review gives an overview of sex-based differences in aortic valve stenosis, spanning from pathophysiological mechanisms and disease progression, clinical presentation, presence of comorbidities, and diagnostic assessment, to treatment and outcomes. In particular, sex-related differences in the degree of aortic valve calcification, the response of the left ventricle to pressure overload, as well as in the referral to procedures, with women being less frequently referred for surgical aortic valve replacement and experiencing longer waiting times for transcatheter procedures, will be discussed. Sex-related differences are also particularly evident in outcomes of patients with severe aortic stenosis undergoing surgical or transcatheter procedures. The apparent sex paradox seen in women undergoing transcatheter aortic valve implantation refers to the phenomenon of women experiencing higher rates of short-term mortality and bleeding events, but demonstrating improved long-term survival as compared to men. Women who undergo surgical aortic valve replacement have generally worse outcomes as compared to men, which is reflected by the inclusion of female sex in surgical risk calculation scores. Hence, a thorough understanding of sex-related differences in aortic valve stenosis is important to provide optimal and personalized patient care

    Impact of cardiac magnetic resonance imaging on human lymphocyte DNA integrity

    Get PDF
    Aims Magnetic resonance (MR) imaging is widely used for diagnostic imaging in medicine as it is considered a safe alternative to ionizing radiation-based techniques. Recent reports on potential genotoxic effects of strong and fast switching electromagnetic gradients such as used in cardiac MR (CMR) have raised safety concerns. The aim of this study was to analyse DNA double-strand breaks (DSBs) in human blood lymphocytes before and after CMR examination. Methods and results In 20 prospectively enrolled patients, peripheral venous blood was drawn before and after 1.5 T CMR scanning. After density gradient cell separation of blood samples, DNA DSBs in lymphocytes were quantified using immunofluorescence microscopy and flow cytometric analysis. Wilcoxon signed-rank testing was used for statistical analysis. Immunofluorescence microscopic and flow cytometric analysis revealed a significant increase in median numbers of DNA DSBs in lymphocytes induced by routine 1.5 T CMR examination. Conclusion The present findings indicate that CMR should be used with caution and that similar restrictions may apply as for X-ray-based and nuclear imaging techniques in order to avoid unnecessary damage of DNA integrity with potential carcinogenic effec

    Hypodense regions in unenhanced CT identify nonviable myocardium: validation versus 18F-FDG PET

    Get PDF
    Purpose: The aim of the present study was to evaluate the accuracy of hypodense regions in non-contrast-enhanced cardiac computed tomography (unenhanced CT) to identify nonviable myocardial scar tissue. Methods: Hypodense areas were visually identified in unenhanced CT of 80 patients in the left ventricular anterior, apical, septal, lateral and inferior myocardium and CT density was measured in Hounsfield units (HU). Findings were compared to 18F-fluorodeoxyglucose uptake by positron emission tomography (FDG PET), which served as the standard of reference to distinguish scar (<50% FDG uptake) from viable tissue (≥50% uptake). Results: Visually detected hypodense regions demonstrated a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 74, 97, 84 and 94%, respectively. A receiver-operating characteristic (ROC) curve analysis revealed a cutoff value of mean HU at <28.8 for predicting scar tissue with an area under the curve of 0.93 yielding a sensitivity, specificity, PPV and NPV of 94, 90, 67 and 99%, respectively. Conclusion: Hypodense regions in unenhanced cardiac CT scans allow accurate identification of nonviable myocardial scar tissu

    Image quality in low-dose coronary computed tomography angiography with a new high-definition CT scanner

    Get PDF
    A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm—adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n=93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014mSv/mGy×cm). The mean image quality score from HDCT versus SDCT was comparable (2.02±0.68 vs. 2.00±0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7±0.6mSv, range 1.0-3.7mSv) and SDCT (1.9±0.8mSv, range 0.8-5.5mSv; P=n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluate

    Sex differences in treatment and outcomes of patients with in-hospital ST-elevation myocardial infarction.

    Full text link
    BACKGROUND AND HYPOTHESIS Two cohorts face high mortality after ST-elevation myocardial infarction (STEMI): females and patients with in-hospital STEMI. The aim of this study was to evaluate sex differences in ischemic times and outcomes of in-hospital STEMI patients. METHODS Consecutive STEMI patients treated with percutaneous coronary intervention (PCI) were prospectively recruited from 30 hospitals into the Victorian Cardiac Outcomes Registry (2013-2018). Sex discrepancies within in-hospital STEMIs were compared with out-of-hospital STEMIs. The primary endpoint was 12-month all-cause mortality. Secondary endpoints included symptom-to-device (STD) time and 30-day major adverse cardiovascular events (MACE). To investigate the relationship between sex and 12-month mortality for in-hospital versus out-of-hospital STEMIs, an interaction analysis was included in the multivariable models. RESULTS A total of 7493 STEMI patients underwent PCI of which 494 (6.6%) occurred in-hospital. In-hospital versus out-of-hospital STEMIs comprised 31.9% and 19.9% females, respectively. Female in-hospital STEMIs were older (69.5 vs. 65.9 years, p = .003) with longer adjusted geometric mean STD times (104.6 vs. 94.3 min, p < .001) than men. Female versus male in-hospital STEMIs had no difference in 12-month mortality (27.1% vs. 20.3%, p = .92) and MACE (22.8% vs. 19.3%, p = .87). Female sex was not independently associated with 12-month mortality for in-hospital STEMIs which was consistent across the STEMI cohort (OR: 1.26, 95% CI: 0.94-1.70, p = .13). CONCLUSIONS In-hospital STEMIs are more frequent in females relative to out-of-hospital STEMIs. Despite already being under medical care, females with in-hospital STEMIs experienced a 10-min mean excess in STD time compared with males, after adjustment for confounders. Adjusted 12-month mortality and MACE were similar to males

    CT coronary angiography: impact of adapted statistical iterative reconstruction (ASIR) on coronary stenosis and plaque composition analysis

    Get PDF
    To assess the impact of adaptive statistical iterative reconstruction (ASIR) on coronary plaque volume and composition analysis as well as on stenosis quantification in high definition coronary computed tomography angiography (CCTA). We included 50 plaques in 29 consecutive patients who were referred for the assessment of known or suspected coronary artery disease (CAD) with contrast-enhanced CCTA on a 64-slice high definition CT scanner (Discovery HD 750, GE Healthcare). CCTA scans were reconstructed with standard filtered back projection (FBP) with no ASIR (0%) or with increasing contributions of ASIR, i.e. 20, 40, 60, 80 and 100% (no FBP). Plaque analysis (volume, components and stenosis degree) was performed using a previously validated automated software. Mean values for minimal diameter and minimal area as well as degree of stenosis did not change significantly using different ASIR reconstructions. There was virtually no impact of reconstruction algorithms on mean plaque volume or plaque composition (e.g. soft, intermediate and calcified component). However, with increasing ASIR contribution, the percentage of plaque volume component between 401 and 500 HU decreased significantly (p<0.05). Modern image reconstruction algorithms such as ASIR, which has been developed for noise reduction in latest high resolution CCTA scans, can be used reliably without interfering with the plaque analysis and stenosis severity assessmen

    Differences in outcomes of patients with in-hospital versus out-of-hospital ST-elevation myocardial infarction: a registry analysis

    Full text link
    OBJECTIVES Patients with ST-elevation myocardial infarction (STEMI) that occur while already in hospital ('in-hospital STEMI') face high mortality. However, data about this patient population are scarce. We sought to investigate differences in reperfusion and outcomes of in-hospital versus out-of-hospital STEMI. DESIGN, SETTING AND PARTICIPANTS Consecutive patients with STEMI all treated with percutaneous coronary intervention (PCI) across 30 centres were prospectively recruited into the Victorian Cardiac Outcomes Registry (2013-2018). PRIMARY AND SECONDARY OUTCOMES Patients with in-hospital STEMI were compared with patients with out-of-hospital STEMI with a primary endpoint of 30-day major adverse cardiovascular events (MACE). Secondary endpoints included ischaemic times, all-cause mortality and major bleeding. RESULTS Of 7493 patients with PCI-treated STEMI, 494 (6.6%) occurred in-hospital. Patients with in-hospital STEMI were older (67.1 vs 62.4 years, p<0.001), more often women (32% vs 19.9%, p<0.001), with more comorbidities. Patients with in-hospital STEMI had higher 30-day MACE (20.4% vs 9.8%, p<0.001), mortality (12.1% vs 6.9%, p<0.001) and major bleeding (4.9% vs 2.3%, p<0.001), than patients with out-of-hospital STEMI. According to guideline criteria, patients with in-hospital STEMI achieved symptom-to-device times of ≤70 min and ≤90 min in 29% and 47%, respectively. Patients with out-of-hospital STEMI achieved door-to-device times of ≤90 min in 71%. Occurrence of STEMI while in hospital independently predicted higher MACE (adjusted OR 1.77, 95% CI 1.33 to 2.36, p<0.001) and 12-month mortality (adjusted OR 1.49, 95% CI 1.08 to 2.07, p<0.001). CONCLUSIONS Patients with in-hospital STEMI experience delays to reperfusion with significantly higher MACE and mortality, compared with patients with out-of-hospital STEMI, after adjustment for confounders. Focused strategies are needed to improve recognition and outcomes in this high-risk and understudied population

    Sex discrepancies in pathophysiology, presentation, treatment, and outcomes of severe aortic stenosis

    Get PDF
    This review gives an overview of sex-based differences in aortic valve stenosis, spanning from pathophysiological mechanisms and disease progression, clinical presentation, presence of comorbidities, and diagnostic assessment, to treatment and outcomes. In particular, sex-related differences in the degree of aortic valve calcification, the response of the left ventricle to pressure overload, as well as in the referral to procedures, with women being less frequently referred for surgical aortic valve replacement and experiencing longer waiting times for transcatheter procedures, will be discussed. Sex-related differences are also particularly evident in outcomes of patients with severe aortic stenosis undergoing surgical or transcatheter procedures. The apparent sex paradox seen in women undergoing transcatheter aortic valve implantation refers to the phenomenon of women experiencing higher rates of short-term mortality and bleeding events, but demonstrating improved long-term survival as compared to men. Women who undergo surgical aortic valve replacement have generally worse outcomes as compared to men, which is reflected by the inclusion of female sex in surgical risk calculation scores. Hence, a thorough understanding of sex-related differences in aortic valve stenosis is important to provide optimal and personalized patient care

    First experience with single-source, dual-energy CCTA for monochromatic stent imaging

    Get PDF
    Aims Single-source, dual-energy coronary computed tomography angiography (CCTA) with monochromatic image reconstruction allows significant noise reduction. The aim of the study was to evaluate the impact of monochromatic CCTA image reconstruction on coronary stent imaging, as the latter is known to be affected by artefacts from highly attenuating strut material resulting in artificial luminal narrowing. Methods and results Twenty-one patients with 62 stents underwent invasive coronary angiography and single-source, dual-energy CCTA after stent implantation. Standard polychromatic images as well as eight monochromatic series (50, 60, 70, 80, 90, 100, 120, and 140 keV) were reconstructed for each CCTA. Signal and noise were measured within the stent lumen and in the aortic root. Mean in-stent luminal diameter was assessed in all CCTA reconstructions and compared with quantitative invasive coronary angiography (QCA). Luminal attenuation was higher in the stent than in the aortic root throughout all monochromatic reconstructions (P < 0.001). An increase in monochromatic energy was associated with a decrease in luminal attenuation values (P < 0.001). The mean in-stent luminal diameter underestimation by monochromatic CCTA compared with QCA was 90% at low monochromatic energy (50 keV) and improved to 37% at high monochromatic (140 keV) reconstruction while stent diameter was underestimated by 39% with standard CCTA. Conclusion Monochromatic CCTA can be used reliably in patients with coronary stents. However, reconstructions with energies below 80 keV are not recommended as the blooming artefacts are most pronounced at such low energies, resulting in up to 90% stent diameter underestimatio
    • …