41 research outputs found

    Influence of the activation mode on long-term bond strength and endogenous enzymatic activity of dual-cure resin cements

    Get PDF
    Objective: To investigate the long-term microtensile bond strength (µTBS), interfacial nanoleakage expression (NL), and adhesive stability of dual-cure resin cements with/out light activation to dentin. Materials and methods: Composite overlays (N = 20) were luted to deep dentin surfaces with RelyX Ultimate (RXU, 3M) or Variolink EstheticDC (VAR, Ivoclar-Vivadent). A universal adhesive was used for bonding procedures (iBond universal, Heraeus Kulzer). The resin cements were either self-cured (SC; 1 h at 37 Â°C) or dual-cured (DC; 20s light-cure followed by 15 min self-cure at 37 Â°C). Specimens were submitted to µTBS immediately (T0) or after 1 year of laboratory storage (T12). The fracture pattern was evaluated using scanning electron microscopy (SEM). Data were statistically analyzed with two-way ANOVA/Tukey test. Further, the NL was quantified and analyzed (chi-square test) and in situ zymography was performed to evaluate the endogenous enzymatic activity within the hybrid layer (HL) at T0 and T12 (Mann–Whitney test). The significance level for all statistical tests was set at p = 0.05. Results: DC resulted in higher bond strength and decreased fluorescence at the adhesive interface, irrespective of the material and the storage period (p < 0.05). Significantly lower bonding performances (p < 0.05) and higher endogenous enzymatic activity (p < 0.05) were observed within the HL at T12 compared to T0 in all tested groups. Conclusions: Light-curing the dual-cure resin cements, more than the cement materials, accounted for good bonding performances and higher HL stability over time when used with a universal adhesive. Clinical significance The curing condition influences the bonding performances of dual-cure resin cements to dentin when used with a universal adhesive

    Effect of Orthophosphoric Acid and Er:YAG Laser Etching on Micro-shear Bond Strength to Enamel: An In Vitro Pilot Study

    Get PDF
    Background: Dental conditioning is one of the most important phases during enamel bonding procedures to obtain clean surfaces, smear layer removal with collagen active sites and hydroxyapatite exposure. Objective: The aim of this study was to compare the micro-shear bond strength (ÎĽSBS) of different adhesive systems after two different etching techniques: 37% orthophosphoric acid (H3PO4) and Er:YAG laser. Methods: Ninety permanent extracted molars were embedded into epoxy resin blocks and sectioned longitudinally. Specimens were randomly assigned to one of the following groups (n=30), depending on the etching protocol: 37% H3PO4 for 30 s (Group 1), Er:YAG laser 100mJ-10Hz (Group 2), and Er:YAG laser 100mJ-10Hz followed by 37% H3PO4 for 30 s (Group 3). Each group was further divided into two subgroups depending on the bonding agent used on enamel (n=15): A) EE-Bond (Tokuyama) and B) Peak universal (Ultradent). A two-way analysis of variance (two-way ANOVA) was conducted and the level of significance was set to p=0.05. Results: The etching procedure was a significant factor influencing the results (p=0.006), while no differences were observed for the two adhesive systems tested (p>0.05). Group 3 recorded the highest bond strength values, according to the following sequel: Group 3 < Group 2 < Group 1 < 0.05. Conclusion: The combination of phosphoric acid etching with Er:YAG laser provided the most favourable bond strength to enamel. Further morphological studies are currently ongoing

    Does immediate dentin sealing influence postoperative sensitivity in teeth restored with indirect restorations? A systematic review and meta-analysis

    Get PDF
    Objective: This study comprehensively reviewed clinical trials that investigated the effect of immediate dentin sealing (IDS) technique on postoperative sensitivity (POS) and clinical performance of indirect restorations. Materials and methods: The systematic review was conducted according to the preferred reporting items for systematic reviews and meta-analyses statement, and was guided by the PICOS strategy. Clinical trials in which adult patients received at least one indirect restoration cemented with IDS approach and one restoration cemented following the delayed dentin sealing (DDS) were considered. Results: Following title screening and full-text reading, four studies met the inclusion criteria and were included for qualitative synthesis, while two studies were selected for quantitative synthesis. According to Risk of bias-2 tool, two studies were classified as “some concerns” for the outcome POS. No statistically significant differences were found between teeth restored with indirect restorations using the IDS and DDS approach for POS (p > 0.05), neither at the baseline (very low certainty of evidence according to GRADE) nor after 2 years of follow-up (low certainty of evidence according to GRADE). Conclusion: There is low-certainty evidence that IDS does not reduce POS in teeth restored with indirect restorations. Clinical significance: There is no clinical evidence to favor IDS over DDS when restoring teeth with indirect restorations

    Endogenous enzymatic activity in dentin treated with a chitosan primer

    Get PDF
    The aim of this study was to evaluate the effect of different concentrations of chitosan polymer on dentinal enzymatic activity by means of gelatin and in situ zymography. Human dentin was frozen and ground in a miller. Dentin powder aliquots were demineralized with phosphoric acid and treated with three different concentrations of lyophilized chitosan polymer (1, 0.5 and 0.1 wt%) dissolved in distilled water. Dentin proteins were extracted from each experimental group and electrophoresed under non-reducing conditions in 10% SDS-PAGE containing fluoresceinlabeled gelatin. After 48 h in the incubation buffer at 37 °C, proteolytic activity was registered under long-wave UV light scanner and quantified by using Image J software. Furthermore, additional teeth (n = 4) were prepared for the in situ zymographic analysis in unrestored as well as restored dentin pretreated with the same chitosan primers. The registered enzymatic activity was directly proportional to the chitosan concentration and higher in the restored dentin groups (p < 0.05), except for the 0.1% chitosan primer. Chitosan 0.1% only showed faint expression of enzymatic activity compared to 1% and 0.5% concentrations. Chitosan 0.1% dissolved in water can produce significant reduction in MMPs activity and could possibly contribute to bond strength preservation over time

    Finite element and in vitro study on biomechanics behavior of endodontically treated premolars restored with direct or indirect composite restorations

    Get PDF
    Objectives of the study were to investigate biomechanical properties of severely compromised premolars restored with composite restorations using finite element analysis (FEA), and in vitro fracture resistance test. A 3-D model of an endodontically treated premolar was created in Solidworks. Different composite restorations were modelled (direct restoration-DR; endo-crown-EC; post, core, and crown-C) with two different supporting tissues: periodontal ligament/alveolar bone (B), and polymethyl methacrylate (PMMA). Models were two-point axially loaded occlusally (850 N). Von Mises stresses and strains were calculated. The same groups were further tested for static fracture resistance in vitro (n = 5, 6.0 mm-diameter ball indenter, vertical load). Fracture resistance data were statistically analyzed (p < 0.050). The highest stresses and strains in all FEA models were observed on occlusal and vestibular cervical surfaces, corresponding to fracture propagation demonstrated in vitro. C showed the lowest stress in dentin, while EC showed lower stresses and strains in crown cement. B models demonstrated larger high stress areas in the root than PMMA models. No significant differences in fracture resistance (N) were observed between groups (DR: 747.7 ± 164.0, EC: 867.3 ± 108.1, C: 866.9 ± 126.3; p = 0.307). More conservative restorations seem a feasible alternative for endodontically treated premolars to conventional post-core-crown

    Comparative Membranome Expression Analysis in Primary Tumors and Derived Cell Lines

    Get PDF
    Despite the wide use of cell lines in cancer research, the extent to which their surface properties correspond to those of primary tumors is poorly characterized. The present study addresses this problem from a transcriptional standpoint, analyzing the expression of membrane protein genes - the Membranome – in primary tumors and immortalized in-vitro cultured tumor cells. 409 human samples, deriving from ten independent studies, were analyzed. These comprise normal tissues, primary tumors and tumor derived cell lines deriving from eight different tissues: brain, breast, colon, kidney, leukemia, lung, melanoma, and ovary. We demonstrated that the Membranome has greater power than the remainder of the transcriptome when used as input for the automatic classification of tumor samples. This feature is maintained in tumor derived cell lines. In most cases primary tumors show maximal similarity in Membranome expression with cell lines of same tissue origin. Differences in Membranome expression between tumors and cell lines were analyzed also at the pathway level and biological themes were identified that were differentially regulated in the two settings. Moreover, by including normal samples in the analysis, we quantified the degree to which cell lines retain the Membranome up- and down- regulations observed in primary tumors with respect to their normal counterparts. We showed that most of the Membranome up-regulations observed in primary tumors are lost in the in-vitro cultured cells. Conversely, the majority of Membranome genes down-regulated upon tumor transformation maintain lower expression levels also in the cell lines. This study points towards a central role of Membranome genes in the definition of the tumor phenotype. The comparative analysis of primary tumors and cell lines identifies the limits of cell lines as a model for the study of cancer-related processes mediated by the cell surface. Results presented allow for a more rational use of the cell lines as a model of cancer

    Biofilm in Endodontics: In Vitro Cultivation Possibilities, Sonic-, Ultrasonic-and Laser-Assisted Removal Techniques and Evaluation of the Cleaning Efficacy

    Get PDF
    Incomplete and inadequate removal of endodontic biofilm during root canal treatment often leads to the clinical failure. Over the past decade, biofilm eradication techniques, such as sonication of irrigant solutions, ultrasonic and laser devices have been investigated in laboratory settings. This review aimed to give an overview of endodontic biofilm cultivation methods described in papers which investigated sonic-, ultrasonic-and Er:Yag laser-assisted biofilm removal techniques. Furthermore, the effectiveness of these removal techniques was discussed, as well as methods used for the evaluation of the cleaning efficacy. In general, laser assisted agitation, as well as ultrasonic and sonic activation of the irrigants provide a more efficient biofilm removal compared to conventional irrigation conducted by syringe/needle. The choice of irrigant is an important factor for reducing the bacterial contamination inside the root canal, with water and saline being the least effective. Due to heterogeneity in methods among the reviewed studies, it is difficult to compare sonic-, ultrasonic-and Er:Yag laser-assisted techniques among each other and give recommendations for the most efficient method in biofilm removal. Future studies should standardize the methodology regarding biofilm cultivation and cleaning methods, root canals with complex morphology should be introduced in research, with the aim of simulating the clinical scenario more closely

    Bond Strength to Lithium-Disilicate Ceramic after Different Surface Cleaning Approaches

    Get PDF
    Purpose: To evaluate the effect of different lithium-disilicate (LiSi) glass-ceramic surface decontamination procedures on the shear bond strength (SBS) to resin cement. Materials and methods: Seventy CAD/CAM LiSi ceramic specimens (IPS e.max CAD, Ivoclar) were cut and sintered. Fifty specimens were treated with 5% hydrofluoric acid (HF) for 20 s, while 20 were left untreated. All 70 specimens were then contaminated with human saliva and try-in silicone paste. The following surface cleaning methods were investigated (n = 10): C: water rinsing (control); PA: 37% H3PO4 etching for 20 s; E: 70% ethanol applied for 20 s; CP: cleaning paste (Ivoclean, Ivoclar) brushed for 20 s; HFSEP: self-etching ceramic primer (Monobond Etch&Prime, Ivoclar) rubbed for 20 s; HF: 5% HF applied for 20 s or no HF etching prior to contamination; SEP: self-etching ceramic primer rubbed for 20 s and no HF etching prior to contamination. Composite cylinders were created and luted with an adhesive resin cement to the decontaminated surfaces. After storage for 24 h at 37°C, the SBS test was conducted. Two fractured specimens per group were observed under SEM to perform fractographic analysis. The data were statistically analyzed with p set at <0.05. Results: The type of surface cleaning approach influenced bond strength (p < 0.001). HFSEP, SEP, and HF attained higher SBS (p < 0.001) compared to other groups. None of the approaches were able to completely remove contaminants from the ceramic surfaces. SEM images showed residual traces of contaminants on CP-treated surfaces. Conclusions: The self-etching ceramic primer enhanced bond strength to contaminated LiSi ceramic surfaces, irrespective of previous treatment with hydrofluoric acid.Purpose: To evaluate the effect of different lithium disilicate (LiSi) glass-ceramic surface decontamination procedures on the shear bond strength (SBS) to resin cement. Materials and Methods: Seventy CAD/CAM LiSi ceramic specimens (IPS e.max CAD – Ivoclar) were cut and sintered. Fifty specimens were treated by 5% hydrofluoric acid (HF) for 20s, while 20 were left untreated. All 70 specimens were then contaminated with human saliva and try-in silicone paste. The following surface cleaning methods were investigated (n=10): G1) water rinsing (control, C); G2) 37% H3PO4 etching for 20s (PA); G3) 70% ethanol applied for 20s (E); G4) Ivoclean (Ivoclar) brushed for 20s (IVO); G5) Monobond Etch&Prime rubbed for 20s (MEPHF); G6) 5% hydrofluoric acid applied for 20s (HF)-no HF etching prior to contamination; G7) MEP rubbed for 20s (MEP)-no HF etching prior to contamination. Composite cylinders were created and luted with an adhesive resin cement to the decontaminated surfaces. After storage for 24 h at 37 °C the SBS test was conducted. Two fractured specimens per group were observed under SEM to perform fractographic analysis. Data were statistically analyzed (p<0.05). Results: The type of surface cleaning approach influenced bond strength (P<0.001). MEPHF, MEP and HF attained higher SBS (P<0.001) compared to other groups. None of the approaches were able to completely remove contaminants from the ceramic surfaces. SEM images showed residual traces of contaminants on the IVO-treated surfaces. Conclusions: The self-etch ceramic primer was able to enhance bond strength to contaminated LiSi ceramic surfaces, irrespective the previous treatment with hydrofluoric acid
    corecore