49 research outputs found

    Use of Omniflow® II Biosynthetic Graft for the Treatment of Vascular Graft and Endograft Infections

    Get PDF
    Background: Vascular graft/endograft infection is a rare but life-threatening complication of cardiovascular surgery and remains a surgical challenge. Several different graft materials are available for the treatment of vascular graft/endograft infection, each having its own advantages and disadvantages. Biosynthetic vascular grafts have shown low reinfection rates and could be a potential second best after autologous veins in the treatment of vascular graft/endograft infection. Therefore, the aim of our study was to evaluate the efficacy and morbidity of Omniflow® II for the treatment of vascular graft/endograft infection.Methods: A multicenter retrospective cohort study was performed to evaluate the use of Omniflow® II in the abdominal and peripheral region to treat vascular graft/endograft infection between January 2014 and December 2021. Primary outcome was recurrent vascular graft infection. Secondary outcomes included primary patency, primary assisted patency, secondary patency, all-cause mortality, and major amputation.Results: Fifty-two patients were included with a median follow-up duration of 26.5 (10.8–54.8) months. Nine (17%) grafts were implanted in intracavitary position and 43 (83%) in peripheral position. Most grafts were used as femoral interposition (n = 12, 23%), femoro-femoral crossover (n = 10, 19%), femoro-popliteal (n = 8, 15%), and aorto-bifemoral (n = 8, 15%) graft. Fifteen (29%) grafts were implanted extra-anatomically and 37 (71%) in situ. Eight patients (15%) presented with reinfection during follow-up, most of these patients received an aorto-bifemoral graft (n = 3, 38%). Intracavitary vascular grafting had a 33% (n = 3) reinfection rate and peripheral grafting 12% (n = 5; P = 0.025). The estimated primary patencies at 1, 2, and 3 years were 75%, 72%, and 72% for peripherally located grafts and 58% (at all timepoints) for intracavitary grafts (P = 0.815). Secondary patencies at 1, 2, and 3 years were 77% (at all timepoints) for peripherally located prostheses and 75% (at all timepoints) for intracavitary prostheses (P = 0.731). A significantly higher mortality during follow-up was observed in patients who received an intracavitary graft compared to patients with a peripheral graft (P = 0.003).Conclusions: This study highlights the efficacy and safety of the Omniflow® II biosynthetic prosthesis for the treatment of vascular graft/endograft infection, in absence of suitable venous material, with acceptable reinfection, patency, and freedom of amputation prevalences, especially in replacing peripheral vascular graft/endograft infection. However, a control group with either venous reconstruction or another alternative graft is needed to make firmer conclusions.</p

    Vascular remodeling and intimal hyperplasia in a novel murine model of arteriovenous fistula failure

    Get PDF
    ObjectiveThe arteriovenous fistula (AVF) still suffers from a high number of failures caused by insufficient outward remodeling and intimal hyperplasia (IH) formation from which the exact mechanism is largely unknown. A suitable animal model is of vital importance in the unraveling of the underlying pathophysiology. However, current murine models of AVF failure do not incorporate the surgical configuration that is commonly used in humans. Because the hemodynamic profile is one of the key determinants that play a role in vascular remodeling in the AVF, it is preferable to use this same configuration in an animal model. Here we describe a novel murine model of AVF failure in which the configuration (end-to-side) is similar to what is most frequently performed in humans.MethodsAn AVF was created in 45 C57BL/6 mice by anastomosing the end of a branch of the external jugular vein to the side of the common carotid artery with interrupted sutures. The AVFs were harvested and analyzed histologically at days 7, 14, and 28. Identical veins of unoperated-on mice served as controls. Intravenous near-infrared fluorescent fluorophores were used to assess the patency of the fistula.ResultsThe patency rates at days 7, 14, and 28 days were 88%, 90%, and 50%, respectively. The mean circumference increased up to day 14, with a maximum 1.4-fold increase at day 7 compared with the control group (1.82 ± 0.7 vs 1.33 ± 0.3 mm; P = .443). Between days 14 and 28, the circumference remained constant (2.36 ± 0.2 vs 2.45 ± 0.2 mm; P = .996). At 7 days after surgery, the intimal area consisted mainly of an acellular layer that was structurally analogous to a focal adherent thrombus. Starting at 14 days after surgery, venous IH increased significantly compared with the unoperated-on group (14 days: 115,090 ± 22,594 μm2, 28 days: 234,619 ± 47,828 μm2, unoperated group: 2368 ± 1056 μm2; P = .001 and P < .001, respectively) and was mainly composed of cells positive for α-smooth muscle actin. We observed leukocytes in the adventitial side of the vein at all time points.ConclusionsOur novel murine AVF model, which incorporates a clinically relevant configuration of the anastomosis, displays similar features that are characteristic of failing human AVFs. Moreover, our findings suggest that coagulation and inflammation could both potentially play an important role in the formation of IH and subsequent AVF failure. Near-infrared fluoroscopy was a suitable alternative for conventional imaging techniques. This murine AVF-model is a valuable addition to the AVF animal model arsenal.Clinical RelevanceThe autologous arteriovenous fistula is considered the preferred choice for vascular access in hemodialysis. However, this type of vascular access suffers from a high failure rate, of which the exact pathophysiology is poorly understood. The use of a clinically relevant murine model provides us with a tool to unravel the pathophysiology and also to develop new therapeutic strategies that can improve the patency of the arteriovenous fistula in hemodialysis patients

    Near-Infrared Fluorescence Imaging of Liver Metastases in Rats using Indocyanine Green

    Get PDF
    BackgroundNear-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is a promising technique to obtain real-time assessment of the extent and number of colorectal liver metastases during surgery. The current study aims to optimize dosage and timing of ICG administration.Materials and MethodsLiver tumors were induced in 18 male WAG/Rij rats by subcapsular inoculation of CC531 rat colorectal cancer cells into three distinct liver lobes. Rats were divided in two groups: imaging after 24 and 48 h or 72 and 96 h after intravenous ICG administration. In each time group, rats were allocated to three dose groups: 0.04, 0.08, or 0.16 mg ICG. Intraoperative imaging and ex vivo measurements were performed using the Mini-FLARE imaging system and confirmed by fluorescence microscopy. Fluorescence intensity was quantified using the Mini-FLARE software and the difference between tumor signal and liver signal (tumor-to-liver ratio; TLR) was calculated.ResultsIn all 18 rats, all colorectal liver metastases (n = 34), some as small as 1.2 mm, were identified using ICG and the Mini-FLARE imaging system. Average tumor-to-liver ratio (TLR) over all groups was 3.0 ± 1.2. TLR was significantly higher in the 72 h time group compared with other time points. ICG dose did not significantly influence TLR, but a trend was found favoring the 0.08 mg dose group. Fluorescence microscopy demonstrated a clear fluorescent rim around the tumor.ConclusionsThis study demonstrates that colorectal cancer liver metastases can be clearly identified during surgery using ICG and the Mini-FLARE imaging system, with optimal timing of 72 h post-injection and an optimal dose of 0.08 mg (0.25 mg/kg) ICG. NIR fluorescence imaging has the potential to improve intraoperative detection of micrometastases and, thus, the completeness of resection

    Clinical Translation of Ex Vivo Sentinel Lymph Node Mapping for Colorectal Cancer Using Invisible Near-Infrared Fluorescence Light

    Get PDF
    BACKGROUND: Sentinel lymph node (SLN) mapping in colorectal cancer may have prognostic and therapeutic significance; however, currently available techniques are not optimal. We hypothesized that the combination of invisible near-infrared (NIR) fluorescent light and ex vivo injection could solve remaining problems of SLN mapping in colorectal cancer. METHODS: The FLARE imaging system was used for real-time identification of SLNs after injection of the NIR lymphatic tracer HSA800 in the colon and rectum of (n = 4) pigs. A total of 32 SLN mappings were performed in vivo and ex vivo after oncologic resection using an identical injection technique. Guided by these results, SLN mappings were performed in ex vivo tissue specimens of 24 consecutive colorectal cancer patients undergoing resection. RESULTS: Lymph flow could be followed in real-time from the injection site to the SLN using NIR fluorescence. In pigs, the SLN was identified in 32 of 32 (100%) of SLN mappings under both in vivo and ex vivo conditions. Clinically, SLNs were identified in all patients (n = 24) using the ex vivo strategy within 5 min after injection of fluorescent tracer. Also, 9 patients showed lymph node involvement (N1 disease). In 1 patient, a 3-mm mesenteric metastasis was found adjacent to a tumor-negative SLN. CONCLUSIONS: The current pilot study shows proof of principle that ex vivo NIR fluorescence-guided SLN mapping can provide high-sensitivity, rapid, and accurate identification of SLNs in colon and rectum. This creates an experimental platform to test optimized, non-FDA-approved NIR fluorescent lymphatic tracers in a clinical setting.Imaging- and therapeutic targets in neoplastic and musculoskeletal inflammatory diseas

    Virtual Liver Resection and Volumetric Analysis of the Future Liver Remnant using Open Source Image Processing Software

    Get PDF
    Ó The Author(s) 2010. This article is published with open access at Springerlink.com Background After extended liver resection, a remnant liver that is too small can lead to postresection liver failure. To reduce this risk, preoperative evaluation of the future liver remnant volume (FLRV) is critical. The open-source OsiriX Ò PAC software system can be downloaded for free and used by nonradiologists to calculate liver volume using a stand-alone Apple computer. The purpose of this study was to assess the accuracy of OsiriX Ò CT volumetry for predicting liver resection volume and FLVR in patients undergoing partial hepatectomy. Methods Preoperative contrast-enhanced liver CT scans of patients who underwent partial hepatectomy were Joost R. van der Vorst and Ronald M. van Dam contributed equally to the study and the manuscript. These authors share first authorship. J. R. van der Vorst R. M. van Dam (&amp;

    Toward Optimization of Imaging System and Lymphatic Tracer for Near-Infrared Fluorescent Sentinel Lymph Node Mapping in Breast Cancer

    Get PDF
    Near-infrared (NIR) fluorescent sentinel lymph node (SLN) mapping in breast cancer requires optimized imaging systems and lymphatic tracers. A small, portable version of the FLARE imaging system, termed Mini-FLARE, was developed for capturing color video and two semi-independent channels of NIR fluorescence (700 and 800 nm) in real time. Initial optimization of lymphatic tracer dose was performed using 35-kg Yorkshire pigs and a 6-patient pilot clinical trial. More refined optimization was performed in 24 consecutive breast cancer patients. All patients received the standard of care using (99m)Technetium-nanocolloid and patent blue. In addition, 1.6 ml of indocyanine green adsorbed to human serum albumin (ICG:HSA) was injected directly after patent blue at the same location. Patients were allocated to 1 of 8 escalating ICG:HSA concentration groups from 50 to 1000 mu M. The Mini-FLARE system was positioned easily in the operating room and could be used up to 13 in. from the patient. Mini-FLARE enabled visualization of lymphatic channels and SLNs in all patients. A total of 35 SLNs (mean = 1.45, range 1-3) were detected: 35 radioactive (100%), 30 blue (86%), and 35 NIR fluorescent (100%). Contrast agent quenching at the injection site and dilution within lymphatic channels were major contributors to signal strength of the SLN. Optimal injection dose of ICG:HSA ranged between 400 and 800 mu M. No adverse reactions were observed. We describe the clinical translation of a new NIR fluorescence imaging system and define the optimal ICG:HSA dose range for SLN mapping in breast cancer.EndocrinologyOV5Oncologic ImagingImaging- and therapeutic targets in neoplastic and musculoskeletal inflammatory diseas

    Near-infrared fluorescence imaging of a solitary fibrous tumor of the pancreas using methylene blue

    No full text

    A quantitative assessment of perfusion of the gastric conduit after oesophagectomy using near-infrared fluorescence with indocyanine green

    Get PDF
    Introduction: Anastomotic leakage is a severe complication after oesophageal resection with gastric conduit reconstruction. Poor perfusion of the gastric conduit plays an important role in the development of anastomotic leakage. Quantitative near-infrared (NIR) fluorescence angiography with indocyanine green (ICG-FA) is an objective technique that can be used for perfusion assessment. This study aims to assess perfusion patterns of the gastric conduit with quantitative ICG-FA. Methods: In this exploratory study, 20 patients undergoing oesophagectomy with gastric conduit reconstruction were included. A standardized NIR ICG-FA video of the gastric conduit was recorded. Postoperatively, the videos were quantified. Primary outcomes were the time-intensity curves and nine perfusion parameters from contiguous regions of interest on the gastric conduit. A secondary outcome was the inter-observer agreement of subjective interpretation of the ICG-FA videos between six surgeons. The inter-observer agreement was tested with an intraclass correlation coefficient (ICC). Results: In a total of 427 curves, three distinct perfusion patterns were recognized: pattern 1 (steep inflow, steep outflow); pattern 2 (steep inflow, minor outflow); and pattern 3 (slow inflow, no outflow). All perfusion parameters were significantly different between the perfusion patterns. The inter-observer agreement was poor – moderate (ICC:0.345,95%CI:0.164–0.584). Discussion: This was the first study to describe perfusion patterns of the complete gastric conduit after oesophagectomy. Three distinct perfusion patterns were observed. The poor inter-observer agreement of the subjective assessment underlines the need for quantification of ICG-FA of the gastric conduit. Further studies should evaluate the predictive value of perfusion patterns and parameters on anastomotic leakage

    Near-Infrared Fluorescence with Indocyanine Green to Assess Bone Perfusion: A Systematic Review

    No full text
    Background: Adequate perfusion of a bone flap is essential for successful reconstruction of osseous defects. Unfortunately, complications related to inadequate bone perfusion are common. Near-infrared fluorescence (NIRF) imaging enables intraoperative visualization of perfusion. NIRF has been investigated in reconstructive surgery to aid the surgeon in clinical perioperative assessment of soft tissue perfusion. However, little is known on the beneficial use of NIRF to assess bone perfusion. Therefore, the aim of this review was to search for studies evaluating NIRF to assess bone perfusion. Methods: A systematic review, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline, was performed. Studies up to October 2021 were included. We extracted data regarding the study population, size and design, reported objective fluorescence parameters and the methodology used for fluorescence imaging and processing. Results: Ten articles were included. Studies reported unevenly on the protocol used for NIRF imaging. Five studies reported objective parameters. Absolute and relative perfusion parameters and parameters derived from maximum fluorescence were reported. The clinical significance of these parameters has not been evaluated in humans. Conclusion: The evidence on bone perfusion as measured with NIRF is limited. More clinical studies are required