790 research outputs found

    Gait analysis of patients with knee osteoarthritis highlights a pathological mechanical pathway and provides a basis for therapeutic interventions

    Get PDF
    Knee osteoarthritis (OA) is a painful and incapacitating disease affecting a large portion of the elderly population, for which no cure exists. There is a critical need to enhance our understanding of OA pathogenesis, as a means to improve therapeutic options. Knee OA is a complex disease influenced by many factors, including the loading environment. Analysing knee biomechanics during walking - the primary cyclic load-bearing activity - is therefore particularly relevant. There is evidence of meaningful differences in the knee adduction moment, flexion moment and flexion angle during walking between non-OA individuals and patients with medial knee OA. Furthermore, these kinetic and kinematic gait variables have been associated with OA progression. Gait analysis provides the critical information needed to understand the role of ambulatory biomechanics in OA development, and to design therapeutic interventions. Multidisciplinary research is necessary to relate the biomechanical alterations to the structural and biological components of OA. Cite this article: Favre J, Jolles BM. Analysis of gait, knee biomechanics and the physiopathology of knee osteoarthritis in the development of therapeutic interventions. EFORT Open Rev 2016;1:368-374. DOI: 10.1302/2058-5241.1.000051

    Walking with shorter stride length could improve knee kinetics of patients with medial knee osteoarthritis.

    Get PDF
    Walking with a shorter stride length (SL) was recently proposed for gait retraining in medial knee osteoarthritis; however it was never assessed in this patient population. This study tested the hypothesis that shortening SL while maintaining walking speed reduces knee adduction (KAM) and flexion (KFM) moments in patients with medial knee osteoarthritis. Walking trials with normal SL and SL reduced by 0.10 m and 0.15 m were recorded for 15 patients (10 men, 55.5 ± 8.7 years old, 24.6 ± 3.0 kg/m <sup>2</sup> ). SL was modified using an augmented reality system displaying target footprints on the floor. Repeated one-way ANOVAs and post-hoc paired t-tests were performed to compare gait measures between normal and reduced SL. The individual effects of SL reduction were analyzed using descriptive statistics. Group analysis indicated significant decreases in KAM impulse with both SL reductions (p < 0.05). No systematic change was observed in the first peaks KAM and KFM when walking with reduced SL (p > 0.05). Individually, 33 % of the patients decreased the peak KAM, whereas 20 % decreased the KAM impulse. Among these patients with a decrease in peak KAM or in KAM impulse, 0 % and 33 % had a simultaneous increase in peak KFM, respectively. In conclusion, this study showed that SL shortening can decrease kinetic measures associated with the progression of medial knee osteoarthritis in some patients, demonstrating the importance of considering SL modifications on an individual basis. While further research is necessary, notably regarding dose-response relationships and long-term effects, these findings are particularly encouraging because SL reductions could be easily integrated into rehabilitation protocols

    Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?

    Get PDF
    Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surger

    A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries

    Get PDF
    The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30m walking trial. The precision in comparison with the reference system was 4.4°, 2.7° and 4.2° for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8°, 0.7° and 1.8°. The averaged ROM of the five patients' healthy knee were 70.1° [standard deviation (SD) 5.8°], 24.0° (SD 3.0°) and 12.0° (SD 6.3°) for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5° (SD 4.1°), 21.7° (SD 4.9°) and 10.2° (SD 4.6°) 1year following the reconstruction. The results for the pathologic knee were 64.5° (SD 6.9°), 20.6° (SD 4.0°) and 19.7° (8.2°) during the first evaluation, and 72.3° (SD 2.4°), 25.8° (SD 6.4°) and 12.4° (SD 2.3°) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surger

    Walking with Different Insoles Changes Lower-Limb Biomechanics Globally in Patients with Medial Knee Osteoarthritis.

    Get PDF
    Using insoles to modify walking biomechanics is of keen interest for the treatment of medial-compartment knee osteoarthritis. So far, insole interventions have focused on reducing the peak of the knee adduction moment (pKAM) and have led to inconsistent clinical outcomes. This study aimed to evaluate the changes in other gait variables related to knee osteoarthritis when patients walk with different insoles to provide insights into the necessity to enlarge the biomechanical analyses to other variables. Walking trials were recorded for 10 patients in four insole conditions. Changes among conditions were computed for six gait variables, including the pKAM. The associations between the changes in pKAM and the changes in the other variables were also assessed individually. Walking with different insoles had noticeable effects on the six gait variables, with high heterogeneity among patients. For all variables, at least 36.67% of the changes were of medium-to-large effect size. The associations with the changes in pKAM varied among variables and patients. In conclusion, this study showed that varying the insole could globally influence ambulatory biomechanics and that limiting measurement to the pKAM could lead to an important loss of information. Beyond the consideration of additional gait variables, this study also encourages personalized interventions to address inter-patient variability
    corecore