1,115 research outputs found

    Precision mass measurements of radioactive nuclei at JYFLTRAP

    Get PDF
    The Penning trap mass spectrometer JYFLTRAP was used to measure the atomic masses of radioactive nuclei with an uncertainty better than 10 keV. The atomic masses of the neutron-deficient nuclei around the N = Z line were measured to improve the understanding of the rp-process path and the SbSnTe cycle. Furthermore, the masses of the neutron-rich gallium (Z = 31) to palladium (Z = 46) nuclei have been measured. The physics impacts on the nuclear structure and the r-process paths are reviewed. A better understanding of the nuclear deformation is presented by studying the pairing energy around A = 100.Comment: 4 pages and 4 figures, RNB7 conf. pro

    Isomeric states close to doubly magic 132^{132}Sn studied with JYFLTRAP

    Full text link
    The double Penning trap mass spectrometer JYFLTRAP has been employed to measure masses and excitation energies for 11/2−11/2^- isomers in 121^{121}Cd, 123^{123}Cd, 125^{125}Cd and 133^{133}Te, for 1/2−1/2^- isomers in 129^{129}In and 131^{131}In, and for 7−7^- isomers in 130^{130}Sn and 134^{134}Sb. These first direct mass measurements of the Cd and In isomers reveal deviations to the excitation energies based on results from beta-decay experiments and yield new information on neutron- and proton-hole states close to 132^{132}Sn. A new excitation energy of 144(4) keV has been determined for 123^{123}Cdm^m. A good agreement with the precisely known excitation energies of 121^{121}Cdm^m, 130^{130}Snm^m, and 134^{134}Sbm^m has been found.Comment: 10 pages, 6 figures, submitted to Phys. Rev.

    Mass measurements in the vicinity of the doubly-magic waiting point 56Ni

    Full text link
    Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu, 58Cu, and 59Zn have been measured directly with a typical precision of better than 0.7 keV and Coulomb displacement energies have been determined. The Q values for proton captures on 55Co, 56Ni, 58Cu, and 59Cu have been measured directly. The precision of the proton-capture Q value for 56Ni(p,gamma)57Cu, Q(p,gamma) = 689.69(51) keV, crucial for astrophysical rp-process calculations, has been improved by a factor of 37. The excitation energy of the proton emitting spin-gap isomer 53Co^m has been measured precisely, Ex = 3174.3(10) keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2- state has been obtained. Except for 53Co, the mass values have been adjusted within a network of 17 frequency ratio measurements between 13 nuclides which allowed also a determination of the reference masses 55Co, 58Ni, and 59Cu.Comment: 14 pages, 13 figures, submitted to Phys. Rev.

    Q_EC values of the Superallowed beta-Emitters 10-C, 34-Ar, 38-Ca and 46-V

    Full text link
    The Q_EC values of the superallowed beta+ emitters 10-C, 34-Ar, 38-Ca and 46-V have been measured with a Penning-trap mass spectrometer to be 3648.12(8), 6061.83(8), 6612.12(7) and 7052.44(10) keV, respectively. All four values are substantially improved in precision over previous results.Comment: 9 pages, 7 figures, 5 table

    Precision mass measurements on neutron-rich rare-earth isotopes at JYFLTRAP - reduced neutron pairing and implications for the rr-process calculations

    Full text link
    The rare-earth peak in the rr-process abundance pattern depends sensitively on both the astrophysical conditions and subtle changes in nuclear structure in the region. This work takes an important step elucidating the nuclear structure and reducing the uncertainties in rr-process calculations via precise atomic mass measurements at the JYFLTRAP double Penning trap. 158^{158}Nd, 160^{160}Pm, 162^{162}Sm, and 164−166^{164-166}Gd have been measured for the first time and the precisions for 156^{156}Nd, 158^{158}Pm, 162,163^{162,163}Eu, 163^{163}Gd, and 164^{164}Tb have been improved considerably. Nuclear structure has been probed via two-neutron separation energies S2nS_{2n} and neutron pairing energy metrics DnD_n. The data do not support the existence of a subshell closure at N=100N=100. Neutron pairing has been found to be weaker than predicted by theoretical mass models. The impact on the calculated rr-process abundances has been studied. Substantial changes resulting in a smoother abundance distribution and a better agreement with the solar rr-process abundances are observed.Comment: 8 pages, 4 figures, accepted for publication in Physical Review Letter

    Diagnostic Utility of Wireless Video-Electroencephalography in Unsedated Dogs

    Get PDF
    Background: Poor agreement between observers on whether an unusual event is a seizure drives the need for a specific diagnostic tool provided by video-electroencephalography (video-EEG) in human pediatric epileptology. Objective: That successful classification of events would be positively associated with increasing EEG recording length and higher event frequency reported before video-EEG evaluation; that a novel wireless video-EEG technique would clarify whether unusual behavioral events were seizures in unsedated dogs. Animals: Eighty-one client-owned dogs of various breeds undergoing investigation of unusual behavioral events at 4 institutions. Methods: Retrospective case series: evaluation of wireless video-EEG recordings in unsedated dogs performed at 4 institutions. Results: Electroencephalography achieved/excluded diagnosis of epilepsy in 58 dogs (72%); 25 dogs confirmed with epileptic seizures based on ictal/interictal epileptiform discharges, and 33 dogs with no EEG abnormalities associated with their target events. As reported frequency of the target events decreased (annually, monthly, weekly, daily, hourly, minutes, seconds), EEG was less likely to achieve diagnosis (P <0.001). Every increase in event frequency increased the odds of achieving diagnosis by 2.315 (95% confidence interval: 1.36-4.34). EEG recording length (mean = 3.69 hours, range: 0.17-22.5) was not associated (P = 0.2) with the likelihood of achieving a diagnosis. Conclusions and Clinical Importance: Wireless video-EEG in unsedated dogs had a high success for diagnosis of unusual behavioral events. This technique offered a reliable clinical tool to investigate the epileptic origin of behavioral events in dogs.Peer reviewe

    Executive function subdomains are associated with post-stroke functional outcome and permanent institutionalization

    Get PDF
    Background and purposeImpairment of executive functions (EFs) is a common cognitive symptom post-stroke and affects independence in daily activities. Previous studies have often relied on brief cognitive tests not fully considering the wide spectrum of EF subdomains. A detailed assessment of EFs was used to examine which of the subdomains and tests have the strongest predictive value on post-stroke functional outcome and institutionalization in long-term follow-up. MethodsA subsample of 62 patients from the Helsinki Stroke Aging Memory Study was evaluated with a battery of seven neuropsychological EF tests 3 months post-stroke and compared to 39 healthy control subjects. Functional impairment was evaluated with the modified Rankin Scale (mRS) and Instrumental Activities of Daily Living (IADL) scale at 3 months, and with the mRS at 15 months post-stroke. Institutionalization was reviewed from the national registers of permanent hospital admissions in up to 21-year follow-up. ResultsThe stroke group performed more poorly than the control group in multiple EF tests. Tests of inhibition, set shifting, initiation, strategy formation and processing speed were associated with the mRS and IADL scale in stroke patients. EF subdomain scores of inhibition, set shifting and processing speed were associated with functional outcome. In addition, inhibition was associated with the risk for earlier institutionalization. ConclusionsExecutive function was strongly associated with post-stroke functional impairment. In follow-up, poor inhibition was related to earlier permanent institutionalization. The results suggest the prognostic value of EF subdomains after stroke.Peer reviewe

    Numerical simulations of fragmentation of the Affleck-Dine condensate

    Full text link
    We present numerical simulations of fragmentation of the Affleck-Dine condensate in two spatial dimensions. We argue analytically that the final state should consist of both Q-balls and anti-Q-balls in a state of maximum entropy, with most of the balls small and relativistic. Such a behaviour is found in simulations on a 100x100 lattice with cosmologically realistic parameter values. During fragmentation process, we observe filament-like texture in the spatial distribution of charge. The total charge in Q-balls is found to be almost equal to the charge in anti-Q-balls and typically orders of magnitude larger than charge asymmetry. Analytical considerations indicate that, apart from geometrical factors, the results of the simulated two dimensional case should apply also to the fully realistic three dimensional case.Comment: 28 pages, 39 figure
    • 

    corecore