1,115 research outputs found
Precision mass measurements of radioactive nuclei at JYFLTRAP
The Penning trap mass spectrometer JYFLTRAP was used to measure the atomic
masses of radioactive nuclei with an uncertainty better than 10 keV. The atomic
masses of the neutron-deficient nuclei around the N = Z line were measured to
improve the understanding of the rp-process path and the SbSnTe cycle.
Furthermore, the masses of the neutron-rich gallium (Z = 31) to palladium (Z =
46) nuclei have been measured. The physics impacts on the nuclear structure and
the r-process paths are reviewed. A better understanding of the nuclear
deformation is presented by studying the pairing energy around A = 100.Comment: 4 pages and 4 figures, RNB7 conf. pro
Isomeric states close to doubly magic Sn studied with JYFLTRAP
The double Penning trap mass spectrometer JYFLTRAP has been employed to
measure masses and excitation energies for isomers in Cd,
Cd, Cd and Te, for isomers in In and
In, and for isomers in Sn and Sb. These first
direct mass measurements of the Cd and In isomers reveal deviations to the
excitation energies based on results from beta-decay experiments and yield new
information on neutron- and proton-hole states close to Sn. A new
excitation energy of 144(4) keV has been determined for Cd. A good
agreement with the precisely known excitation energies of Cd,
Sn, and Sb has been found.Comment: 10 pages, 6 figures, submitted to Phys. Rev.
Mass measurements in the vicinity of the doubly-magic waiting point 56Ni
Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have
been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with
a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu,
58Cu, and 59Zn have been measured directly with a typical precision of better
than 0.7 keV and Coulomb displacement energies have been determined. The Q
values for proton captures on 55Co, 56Ni, 58Cu, and 59Cu have been measured
directly. The precision of the proton-capture Q value for 56Ni(p,gamma)57Cu,
Q(p,gamma) = 689.69(51) keV, crucial for astrophysical rp-process calculations,
has been improved by a factor of 37. The excitation energy of the proton
emitting spin-gap isomer 53Co^m has been measured precisely, Ex = 3174.3(10)
keV, and a Coulomb energy difference of 133.9(10) keV for the 19/2- state has
been obtained. Except for 53Co, the mass values have been adjusted within a
network of 17 frequency ratio measurements between 13 nuclides which allowed
also a determination of the reference masses 55Co, 58Ni, and 59Cu.Comment: 14 pages, 13 figures, submitted to Phys. Rev.
Q_EC values of the Superallowed beta-Emitters 10-C, 34-Ar, 38-Ca and 46-V
The Q_EC values of the superallowed beta+ emitters 10-C, 34-Ar, 38-Ca and
46-V have been measured with a Penning-trap mass spectrometer to be 3648.12(8),
6061.83(8), 6612.12(7) and 7052.44(10) keV, respectively. All four values are
substantially improved in precision over previous results.Comment: 9 pages, 7 figures, 5 table
Precision mass measurements on neutron-rich rare-earth isotopes at JYFLTRAP - reduced neutron pairing and implications for the -process calculations
The rare-earth peak in the -process abundance pattern depends sensitively
on both the astrophysical conditions and subtle changes in nuclear structure in
the region. This work takes an important step elucidating the nuclear structure
and reducing the uncertainties in -process calculations via precise atomic
mass measurements at the JYFLTRAP double Penning trap. Nd, Pm,
Sm, and Gd have been measured for the first time and the
precisions for Nd, Pm, Eu, Gd, and
Tb have been improved considerably. Nuclear structure has been probed
via two-neutron separation energies and neutron pairing energy metrics
. The data do not support the existence of a subshell closure at .
Neutron pairing has been found to be weaker than predicted by theoretical mass
models. The impact on the calculated -process abundances has been studied.
Substantial changes resulting in a smoother abundance distribution and a better
agreement with the solar -process abundances are observed.Comment: 8 pages, 4 figures, accepted for publication in Physical Review
Letter
Diagnostic Utility of Wireless Video-Electroencephalography in Unsedated Dogs
Background: Poor agreement between observers on whether an unusual event is a seizure drives the need for a specific diagnostic tool provided by video-electroencephalography (video-EEG) in human pediatric epileptology. Objective: That successful classification of events would be positively associated with increasing EEG recording length and higher event frequency reported before video-EEG evaluation; that a novel wireless video-EEG technique would clarify whether unusual behavioral events were seizures in unsedated dogs. Animals: Eighty-one client-owned dogs of various breeds undergoing investigation of unusual behavioral events at 4 institutions. Methods: Retrospective case series: evaluation of wireless video-EEG recordings in unsedated dogs performed at 4 institutions. Results: Electroencephalography achieved/excluded diagnosis of epilepsy in 58 dogs (72%); 25 dogs confirmed with epileptic seizures based on ictal/interictal epileptiform discharges, and 33 dogs with no EEG abnormalities associated with their target events. As reported frequency of the target events decreased (annually, monthly, weekly, daily, hourly, minutes, seconds), EEG was less likely to achieve diagnosis (P <0.001). Every increase in event frequency increased the odds of achieving diagnosis by 2.315 (95% confidence interval: 1.36-4.34). EEG recording length (mean = 3.69 hours, range: 0.17-22.5) was not associated (P = 0.2) with the likelihood of achieving a diagnosis. Conclusions and Clinical Importance: Wireless video-EEG in unsedated dogs had a high success for diagnosis of unusual behavioral events. This technique offered a reliable clinical tool to investigate the epileptic origin of behavioral events in dogs.Peer reviewe
Executive function subdomains are associated with post-stroke functional outcome and permanent institutionalization
Background and purposeImpairment of executive functions (EFs) is a common cognitive symptom post-stroke and affects independence in daily activities. Previous studies have often relied on brief cognitive tests not fully considering the wide spectrum of EF subdomains. A detailed assessment of EFs was used to examine which of the subdomains and tests have the strongest predictive value on post-stroke functional outcome and institutionalization in long-term follow-up. MethodsA subsample of 62 patients from the Helsinki Stroke Aging Memory Study was evaluated with a battery of seven neuropsychological EF tests 3 months post-stroke and compared to 39 healthy control subjects. Functional impairment was evaluated with the modified Rankin Scale (mRS) and Instrumental Activities of Daily Living (IADL) scale at 3 months, and with the mRS at 15 months post-stroke. Institutionalization was reviewed from the national registers of permanent hospital admissions in up to 21-year follow-up. ResultsThe stroke group performed more poorly than the control group in multiple EF tests. Tests of inhibition, set shifting, initiation, strategy formation and processing speed were associated with the mRS and IADL scale in stroke patients. EF subdomain scores of inhibition, set shifting and processing speed were associated with functional outcome. In addition, inhibition was associated with the risk for earlier institutionalization. ConclusionsExecutive function was strongly associated with post-stroke functional impairment. In follow-up, poor inhibition was related to earlier permanent institutionalization. The results suggest the prognostic value of EF subdomains after stroke.Peer reviewe
Numerical simulations of fragmentation of the Affleck-Dine condensate
We present numerical simulations of fragmentation of the Affleck-Dine
condensate in two spatial dimensions. We argue analytically that the final
state should consist of both Q-balls and anti-Q-balls in a state of maximum
entropy, with most of the balls small and relativistic. Such a behaviour is
found in simulations on a 100x100 lattice with cosmologically realistic
parameter values. During fragmentation process, we observe filament-like
texture in the spatial distribution of charge. The total charge in Q-balls is
found to be almost equal to the charge in anti-Q-balls and typically orders of
magnitude larger than charge asymmetry. Analytical considerations indicate
that, apart from geometrical factors, the results of the simulated two
dimensional case should apply also to the fully realistic three dimensional
case.Comment: 28 pages, 39 figure
- âŠ