1,890 research outputs found

    Consumer Willingness to Pay for Breads Marketed as "Low-Carbohydrate"

    Get PDF
    Bread producers are taking advantage of healthy feeding habits by developing new "low carbohydrate" products to entice customers. These low carbohydrate breads are generally more expensive than conventional types. This study tests the hypothesis that consumers are willing to pay higher premium for "low carbohydrate" breads at various locations and markets. We use retail data in a hedonic pricing framework to estimate the premium paid for the "low carbohydrate" attribute of bread. Results show that the implicit price of the "low carbohydrate" attribute of bread ranges from about 0.06¢ to 1.1¢ per gram, reflecting the amount consumers are willing to pay above the price of conventional bread.low carbohydrate bread, hedonic price, willingness to pay, Institutional and Behavioral Economics, D12,

    Malaxis monophyllos var. brachypoda, One-leaved Malaxis, new to the Northwest Territories, Canada

    Get PDF
    The orchid, Malaxis monophyllos var. brachypoda, is reported from Yellowknife, this being the first record for the Northwest Territories and an extension of about 650 kilometers to the northeast from the nearest population in northern British Columbia

    Redistributive Justice Cultural Feminism

    Get PDF

    Programable Sound Absorption Performance Enabled by 3D Printing

    Get PDF
    Design of acoustic materials can be achieved through the connection between their geometry and acoustical performance. Here, we propose 3D-printing as an enabling technology that allows us to precisely control an acoustic material’s micro-geometry and orientation, which then eliminates microscopic geometry bias due to conventional manufacturing process, thus realizing precise material characterization at the 3D-printing CAD programming stage. This concept was practiced in the current study focusing on 3D-printing fibrous sound absorbing layers. A fused deposition modeling (FDM) method was applied to produce the fibers. A Tarnow-based airflow resistivity model was implemented together with Johnson-Champoux-Allard and Biot theories for modeling the geometry-performance connection for the fibers. The sound absorption prediction accuracy of the model was validated by E-1050 standing wave tube measurements on the printed sample

    Comparison of Neuromuscular Injuries to the Surgeon during Hand-Assisted and Standard Laparoscopic Urologic Surgery

    Full text link
    Background and Purpose: Hand-assisted procedures have assumed a greater role in the practice of many laparoscopists. We surveyed major laparoscopy program directors to compare the incidence and location of neuromuscular injury to the surgeon during hand-assisted laparoscopic (HAL) and standard laparoscopic (SL) surgery. Materials and Methods: A questionnaire on neuromuscular injuries was e-mailed to 42 laparoscopic program directors. Respondents were instructed to report only injuries or pain associated with laparoscopic surgery when they were the primary responsible surgeon and not during open or endoscopic procedures. Results: Surveys were returned from 23 attending laparoscopic surgeons and 2 laparoscopic fellows. Surgeons reported an average of 3.9 HAL and 6.3 SL cases per month as the primary surgeon. The HAL was completed with the GelPort, LapDisk, Omniport, or a combination of devices 55%, 22%, 5%, and 14%, respectively, of the time. Comparing HAL with SL, there was significantly more hand/wrist, forearm, and shoulder pain/injuries associated with HAL (P < 0.004). There was significantly more neck pain associated with SL than HAL (P < 0.003), but no significant difference in lower-back pain (P = 0.40). Comparing the two most commonly used hand-assist devices (GelPort and LapDisk), the LapDisk demonstrated significantly more hand/wrist pain or injury (P = 0.001). Conclusion: Hand-assisted laparoscopy is associated with more frequent neuromuscular strain to the upper extremity than SL, but SL surgeons experience more neck pain or injury. Surgeon discomfort is also dependent on the type of hand-assist device. The long-term consequences of physical strain on the laparoscopic surgeon are unknown currently, but measures to minimize neuromuscular strain should be considered.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/63117/1/end.2005.19.377.pd

    Rate of force development and the lateralized readiness potential

    Get PDF

    Performance of Two Boron-Modified S-816 Alloys in a Turbojet Engine Operated at 1650 F

    Get PDF
    S-816+B and modified S-816+B cast cobalt-base alloys were evaluated as turbine-bucket materials at 16500 F. Stress-rupture and tensile data obtained from these alloys had indicated satisfactory strength for engine operation at 1650 F. Although both alloys exhibited a limited ductility in room-temperature laboratory impact tests, there was a significant increase in impact resistance in the 1650 F tests. Bucket failures began after 10 hours of engine testing and continued at various intervals during the 107.5-hour test. Bucket lives were short relative to the predicted lives based on stress-rupture considerations (280 hr for S-816+B and 1750 hr for modified S-816+B). No significant difference was apparent in the performance of the two alloy groups. The primary cause of bucket failures in both alloys was mechanical fatigue. Impact damage occurred as a direct result of bucket tip fatigue failures and was a secondary cause of bucket failures. The impact of small pieces of fractured bucket tips on surrounding buckets caused a relatively large amount of impact damage to buckets of both alloys. The amount of impact damage from induced fractures at the bucket midspan, which provided relatively large failed fragments, was no greater than that which occurred as a result of tip failures

    Positional trueness of three removable die designs with different root geometries manufactured using stereolithographic 3D printing.

    Get PDF
    STATEMENT OF PROBLEM Three-dimensional (3D) printed casts are a suitable alternative to dental stone casts. Contemporary dental design computer programs permit designing definitive casts with removable dies with different root geometries and retention mechanisms. Studies on the positional trueness of 3D-printed removable dies with different root geometries are lacking. PURPOSE The purpose of this in vitro study was to investigate the 3D displacements of three 3D-printed removable die designs with different root geometries. MATERIAL AND METHODS The digital file of a dental stone alveolar cast with root-form removable dies (MOD UJ IV Fixed Prosthetics; Ivoclar AG) was used as a reference to create 3 removable die and alveolar cast designs (Root Form, RF; Conical, CON; Cylindric, CYL) with different root geometries in 2 dental design computer programs (DentalCAD 3.1 Rijeka; exocad; GmbH; InLab CAD 22.0; Dentsply Sirona). 3 equidistant Ø1-mm spheres (C, Cervical; M, Middle; O, Occlusal) were designed on the buccal surface of the coronal portion of the removable die to evaluate their displacement. A total of 45 alveolar casts with 45 removable dies were fabricated using a stereolithographic 3D printer (Form 3; Formlabs); each die group consisted of 15 specimens. After fabrication and postprocessing, the specimens were scanned, and their digital files were analyzed in a metrology-grade computer program to evaluate the displacement of the removable dies with respect to the position of the die in the master reference file. Subsequently, the data were analyzed using a 3-way analysis of variance (ANOVA) followed by step-down Bonferroni-corrected pairwise comparisons (α=.05). RESULTS Two statistically significant 2-way interactions were detected between the independent variables, die design and direction (P<.001), and location and direction (P<.001). The post hoc analysis identified significant differences between the displacement values of RF and CYL (P<.001) and RF and the CON (P<.001) designs on the Y axis. The measured displacements were statistically different between the C and O locations on the Y axis (P=.001) and the M and O locations on the Z axis (P=.006). CONCLUSIONS The root geometry of a 3D-printed removable die and alveolar cast can affect seating, and variable degrees of tipping of the removable die can be seen. The seating and congruence of the removable die with the interocclusal space and relationships observed intraorally should be confirmed before adjusting indirect restorations
    corecore