1,081 research outputs found
Ultrasonic detection and identification of fabrication defects in composites
Methods for deliberate fabrication of porosity into carbon/epoxy composite panels and the influence of three-dimensional stitching on the detection of porosity were investigated. Two methods of introducing porosity were investigated. Porosity was simulated by inclusion of glass microspheres, and a more realistic form of porosity was introduced by using low pressure during consolidation. The panels were ultrasonically scanned and the frequency slope of the ultrasonic attenuation coefficient was used to evaluate the two forms of porosity. The influence of stitching on the detection of porosity was studied using panels which were resin transfer molded from stitched plies of knitted carbon fabric and epoxy resin
Experimental Evaluation of Cermet Turbine Stator Blades for Use at Elevated Gas Temperatures
The suitability of cermets for turbine stator blades of a modified turbojet engine was determined at an average turbine-inlet-gas temperature of 2000 F. Such an increase in temperature would yield a premium in thrust from a service engine. Because the cermet blades require no cooling, all the available compressor bleed air could be used to cool a turbine made from conventional ductile alloys. Cermet blades were first run in 100-hour endurance tests at normal gas temperatures in order to evaluate two methods for mounting them. The elevated gas-temperature test was then run using the method of support considered best for high-temperature operation. After 52 hours at 2000 F, one of the group of four cermet blades fractured probably because of end loads resulting from thermal distortion of the spacer band of the nozzle diaphragm. Improved design of a service engine would preclude this cause of premature failure
Mach 6 experimental and theoretical stability and performance of a cruciform missile at angles of attack up to 65 degrees
An experimental and theoretical investigation of the longitudinal and lateral-directional stability and control of an axisymmetric cruciform-finned missile has been conducted at Mach 6. The angle-of-attack range extended from 20 to 65 deg to encompass maximum lift. Longitudinal stability, performance, and trim could be accurately predicted with the fins at a fin roll angle of 0 deg but not when the fins were at a fin roll angle of 45 deg. At this roll angle, windward fin choking occurred at angles of attack above 50 deg and reduced the effectiveness of the fins and caused pitch-up
Recommended from our members
The Interblink Interval in Normal and Dry Eye Subjects
Purpose: Our aim was to extend the concept of blink patterns from average interblink interval (IBI) to other aspects of the distribution of IBI. We hypothesized that this more comprehensive approach would better discriminate between normal and dry eye subjects. Methods: Blinks were captured over 10 minutes for ten normal and ten dry eye subjects while viewing a standardized televised documentary. Fifty-five blinks were analyzed for each of the 20 subjects. Means, standard deviations, and autocorrelation coefficients were calculated utilizing a single random effects model fit to all data points and a diagnostic model was subsequently fit to predict probability of a subject having dry eye based on these parameters. Results: Mean IBI was 5.97 seconds for normal versus 2.56 seconds for dry eye subjects (ratio: 2.33, P = 0.004). IBI variability was 1.56 times higher in normal subjects (P < 0.001), and the autocorrelation was 1.79 times higher in normal subjects (P = 0.044). With regard to the diagnostic power of these measures, mean IBI was the best dry eye versus normal classifier using receiver operating characteristics (0.85 area under curve (AUC)), followed by the standard deviation (0.75 AUC), and lastly, the autocorrelation (0.63 AUC). All three predictors combined had an AUC of 0.89. Based on this analysis, cutoffs of ≤3.05 seconds for median IBI, and ≤0.73 for the coefficient of variation were chosen to classify dry eye subjects. Conclusion: (1) IBI was significantly shorter for dry eye patients performing a visual task compared to normals; (2) there was a greater variability of interblink intervals in normal subjects; and (3) these parameters were useful as diagnostic predictors of dry eye disease. The results of this pilot study merit investigation of IBI parameters on a larger scale study in subjects with dry eye and other ocular surface disorders
Recommended from our members
Investigation of extended blinks and interblink intervals in subjects with and without dry eye
Background: The purpose of this study was to investigate the occurrence and duration of extended blinks ≥ 70 msec and their associated interblink intervals in normal subjects and in subjects with mild to moderate dry eye. Methods: This single-center, prospective, double-blind study included 11 subjects with dry eye and eight subjects with normal eyes. Extended blinks were defined as lid closure in at least two successive video frames (≥70 msec). Digital video imaging of each subject’s eyes was recorded while the subject viewed a 10-minute documentary. The subjects did not know that blink was the outcome being measured. Following capture, the videos were manually analyzed in a masked fashion for the occurrence of extended blinks. The length of the interblink interval (ie, time between blinks) before and after these extended blinks (the interblink interval ratio) was calculated, as well as differences in lid contact times. Results: The dry eye group had a median extended blink duration which was 2.53 times longer than that of the normal group. For subjects with dry eye, interblink intervals post-extended blink were significantly longer than interblink intervals pre-extended blink (P < 0.001). Interblink intervals did not lengthen significantly in normal subjects. In both groups, the duration of the extended blink was significantly (P = 0.001) and positively correlated with interblink interval ratio (post-extended to pre-extended blink interblink interval), such that for each doubling of extended blink duration, the interblink interval ratio increased by 10%. Blinks longer than one second in duration occurred almost exclusively in subjects with dry eye. Conclusion: This study reports three central findings: blink duration tended to be longer in subjects with dry eye; a lengthening of the interblink interval after an extended blink occurred in subjects with dry eye but not in those without dry eye; and a longer blink duration was associated with a significantly increased interblink interval ratio in all subjects
Recommended from our members
Automated grading system for evaluation of ocular redness associated with dry eye
Background: We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. Aim To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Methods: Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0–4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as “horizontality”). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R – 0.83G – 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. Results: The agreement (both Pearson’s and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero variability from session to session. Conclusion: This objective means of grading ocular redness in a unified fashion has potential significance as a new clinical endpoint. In comparisons between computer and investigator, computer grading proved to be more reliable than another investigator using the OCDER scale. The best fitting model based on the present sample, and usable for future studies, was C4=−12.24+2.12C2HOR+0.88C2RED:C4 is the predicted investigator grade, and C2HOR and C2RED are logarithmic transformations of the computer calculated parameters COM-Hor and COM-Red. Considering the superior repeatability, computer automated grading might be preferable to investigator grading in multicentered dry eye studies in which the subtle differences in redness incurred by treatment have been historically difficult to define
The representation of tropical upper tropospheric water in EC Earth V2
Tropical upper tropospheric humidity, clouds, and ice water content, as well as outgoing longwave radiation (OLR), are evaluated in the climate model EC Earth with the aid of satellite retrievals. The Atmospheric Infrared Sounder and Microwave Limb Sounder together provide good coverage of relative humidity. EC Earth's relative humidity is in fair agreement with these observations. CloudSat and CALIPSO data are combined to provide cloud fractions estimates throughout the altitude region considered (500-100 hPa). EC Earth is found to overestimate the degree of cloud cover above 200 hPa and underestimate it below. Precipitating and non-precipitating EC Earth ice definitions are combined to form a complete ice water content. EC Earth's ice water content is below the uncertainty range of CloudSat above 250 hPa, but can be twice as high as CloudSat's estimate in the melting layer. CERES data show that the model underestimates the impact of clouds on OLR, on average with about 9 W m(-2). Regionally, EC Earth's outgoing longwave radiation can be similar to 20 W m(-2) higher than the observation. A comparison to ERA-Interim provides further perspectives on the model's performance. Limitations of the satellite observations are emphasised and their uncertainties are, throughout, considered in the analysis. Evaluating multiple model variables in parallel is a more ambitious approach than is customary
- …