5,817 research outputs found

    Curran, Edward: Humanities Chairman Nomination Hearing (1985): Correspondence 18

    Get PDF

    Gust Generator for a Supersonic Wind Tunnel

    Get PDF
    The effectiveness was investigated of a flat plate gust generator that was located in the nozzle throat of the Lewis 10- by 10-foot supersonic wind tunnel. Gust plates were tested at nozzle wall Mach numbers of 3.1, 2.4, and 2.0. Test results show that the flat plate concept may be used as a gust generator for a wind tunnel; however, more extensive investigation is required to completely define its capabilities and limitations. For the single transient data point recorded, a gust amplitude (decrement) of 0.15 in Mach number was obtained. Analysis of these transient data indicates a response with a corner frequency of at least 8 hertz

    Legal Writing on Statutory Construction

    Get PDF
    This review does not purport to provide a complete critique of the various works in the field of Statutory Construction. It is not directed primarily to the specialist. Instead, it is intended to bring together for the benefit of the general practitioner the various books and other writings on the subject and thus amounts essentially to a bibliography. But an effort has been made to suggest the approach of the longer works and to estimate in some measure their value. Thus this symposium on the subject of Statutory Construction can be rounded out by providing convenient reference to other writings in the field

    Portable hand hold device

    Get PDF
    A hand hold device (A) includes a housing (10) having a hand hold (14) and clamping brackets (32,34) for grasping and handling an object. A drive includes drive lever (23), spur gear (22), and rack gears (24,26) carried on rods (24a, 26a) for moving the clamping brackets. A lock includes ratchet gear (40) and pawl (42) biased between lock and unlock positions by a cantilever spring (46,48) and moved by handle (54). Compliant grip pads (32b, 34b) provide compliance to lock, unlock, and hold an object between the clamp brackets

    Simulation, modelling and development of the metris RCA

    Get PDF
    In partnership with Metris UK we discuss the utilisation of modelling and simulation methods in the development of a revolutionary 7-axis Robot CMM Arm (RCA). An offline virtual model is described, facilitating pre-emptive collision avoidance and assessment of optimal placement of the RCA relative to scan specimens. Workspace accessibility of the RCA is examined under a range of geometrical assumptions and we discuss the effects of arbitrary offsets resulting from manufacturing tolerances. Degeneracy is identified in the number of ways a given pose may be attained and it is demonstrated how a simplified model may be exploited to solve the inverse kinematics problem of finding the “correct” set of joint angles. We demonstrate how the seventh axis may be utilised to avoid obstacles or otherwise awkward poses, giving the unit greater dexterity than traditional CMMs. The results of finite element analysis and static force modelling on the RCA are presented which provide an estimate of the forces exerted on the internal measurement arm in a range of poses

    Characteristics, accuracy and reverification of robotised articulated arm CMMs

    Get PDF
    VDI article 2617 specifies characteristics to describe the accuracy of articulated arm coordinate measuring machines (AACMMs) and outlines procedures for checking them. However the VDI prescription was written with a former generation of machines in mind: manual arms exploiting traditional touch probe technologies. Recent advances in metrology have given rise to noncontact laser scanning tools and robotic automation of articulated arms – technologies which are not adequately characterised using the VDI specification. In this paper we examine the “guidelines” presented in VDI 2617, finding many of them to be ambiguous and open to interpretation, with some tests appearing even to be optional. The engineer is left significant flexibility in the execution of the test procedures and the manufacturer is free to specify many of the test parameters. Such flexibility renders the VDI tests of limited value and the results can be misleading. We illustrate, with examples using the Nikon RCA, how a liberal interpretation of the VDI guidelines can significantly improve accuracy characterisation and suggest ways in which to mitigate this problem. We propose a series of stringent tests and revised definitions, in the same vein as VDI 2617 and similar US standards, to clarify the accuracy characterisation process. The revised methodology includes modified acceptance and reverification tests which aim to accommodate emerging technologies, laser scanning devices in particular, while maintaining the spirit of the existing and established standards. We seek to supply robust re-definitions for the accepted terms “zero point” and “useful arm length”, pre-supposing nothing about the geometry of the measuring device. We also identify a source of error unique to robotised AACMMs employing laser scanners – the forward-reverse pass error. We show how eliminating this error significantly improves the repeatability of a device and propose a novel approach to the testing of probing error based on statistical uncertainty

    Effect of urinary pH and diatrizoate on Bence Jones protein nephrotoxicity in the rat

    Get PDF
    Effect of urinary pH and diatrizoate on Bence Jones protein nephrotoxicity in the rat. Both low urinary pH and radiocontrast agents may intensify myeloma nephrotoxicity. To study the effects of these factors, we determined inulin clearances (CIn) before and after infusions of human Bence Jones protein (BJP) in male Sprague-Dawley rats in a dose previously shown to be nephrotoxic. Rats that drank 0.15 M NaHCO3 for 48 hr before study had no change in CIn (+ 3 ± 20%) after BJP unlike those that drank 0.15 M NH4Cl (- 33 ± 14%, P < 0.05); urinary pH differed (7.6 ± 0.1 vs. 6.2 ± 0.1, P < 0.05), but urinary flow rates did not. The acidifying regimen was used in all subsequent groups. Infusion of diatrizoate (DTZ) after BJP produced a further decrease in CIn (- 85 ± 8%, P < 0.05). In contrast, infusion of albumin, which raised plasma protein concentration to that seen in BJP-infused rats, did not change CIn (+ 39 ± 17%). Infusion of beta-lactoglobulin also led to a greater decrease in CIn after DTZ (- 35 ± 9 vs. - 67 ± 8%, P < 0.05), but myoglobin did not (- 58 ± 7 vs. - 54 ± 12%). Urinary pH and flow rate did not differ between any DTZ-infused group and its appropriate control. These data suggest that aciduria independent of urinary flow rate increases the nephrotoxicity of BJP. In this setting, DTZ further intensifies the nephrotoxicity of BJP as well as some but not all filterable proteins.Effet du pH urinaire et du diatrizoate sur la nĂ©phrotoxicitĂ© de la protĂ©ine de Bence Jones chez le rat. Un pH urinaire bas et les produits de contraste peuvent accroĂźtre la nĂ©phrotoxitĂ© du myĂ©lome. Pour Ă©tudier les effets de ces facteurs, nous avons dĂ©terminĂ© les clearances de l'inuline (CIn) avant et aprĂšs perfusion de protĂ©ine de Bence Jones humaine (BJP) chez des rats mĂąles Sprague-Dawley Ă  dose prĂ©alablement montrĂ©e nĂ©phrotoxique. Les rats qui buvaient 0,15 M NaHCO3 pendant 48 hr avant l'Ă©tude n'avaient pas de modification de CIn (+ 3 ± 20%) aprĂšs BJP Ă  la diffĂ©rence de ceux qui buvaient 0,15 M NH4Cl (- 33 ± 14%, P < 0,05); les pH urinaires diffĂ©raient (7,6 ± 0,1 contre 6,2 ± 0,1, P < 0,05), mais non les dĂ©bits urinaires. Le rĂ©gime acidifiant a Ă©tĂ© utilisĂ© chez tous les groupes ultĂ©rieurs. La perfusion de diatrizoate (DTZ) aprĂšs BJP a entraĂźnĂ© une diminution supplĂ©mentaire de CIn (- 85 ± 8%, P < 0,05). A l'opposĂ© une perfusion d'albumine, qui augmentait la protidĂ©mie Ă  la valeur observĂ©e chez les rats perfusĂ©s avec BJP ne modifiait pas CIn (+ 39 ± 17%). Une perfusion de bĂ©ta-lactoglobuline a Ă©galement entraĂźnĂ© une plus forte baisse de CIn aprĂšs DTZ (- 35 ± 9 contre - 67 ± 8%, P < 0,05), mais non de la myoglobine (- 58 ± 7 contre - 54 ± 12%). Le pH et le dĂ©bit urinaires ne diffĂ©raient pas entre aucun des groupes perfusĂ©s par le DTZ et leur contrĂŽle appropriĂ©. Ces donnĂ©es suggĂšrent que l'acidurie, indĂ©pendamment du dĂ©bit urinaire, augmente la nĂ©phrotoxicitĂ© de la BJP. Dans ce schĂ©ma, DTZ accentue encore la nĂ©phrotoxicitĂ© de la BJP, de mĂȘme que certaines, mais non toutes les protĂ©ines filtrables

    Self Reported Incidence and Morbidity of Acute Respiratory Illness among Deployed U.S. Military in Iraq and Afghanistan

    Get PDF
    BACKGROUND: Historically, respiratory infections have had a significant impact on U.S. military missions. Deployed troops are particularly at high risk due to close living conditions, stressful work environments and increased exposure to pathogens. To date, there are limited data available on acute respiratory illness (ARI) among troops deployed in support of ongoing military operations, specifically Operation Enduring Freedom (OEF) and Operation Iraqi Freedom (OIF). METHODS: Using self-report data from two sources collected from troops deployed to Iraq, Afghanistan and the surrounding region, we analyzed incidence and risk factors for ARI. Military personnel on mid-deployment Rest & Recuperation (R&R) or during redeployment were eligible to participate in the voluntary self-report survey. RESULTS: Overall, 39.5% reported having at least one ARI. Of these, 18.5% sought medical care and 33.8% reported having decreased job performance. The rate of self-reported ARI was 15 episodes per 100 person-months among those taking the voluntary survey, and 24.7 episodes per 100 person-months among those taking the clinic health questionnaire. Negative binomial regression analysis found female sex, Navy branch of service and lack of flush toilets to be independently associated with increased rates of ARI. Deployment to OIF, increasing age and higher rank were also positively associated with ARI risk. CONCLUSIONS: The overall percentage of deployed military personnel reporting at least one acute respiratory illness decreased since earlier parts of OIF/OEF. However, the reported effect on job performance increased tremendously. The most important factors associated with increased respiratory infection are female sex, Navy branch of service, lack of improved latrine facilities, deployment to OIF, increasing age and higher rank

    HST ultraviolet spectral energy distributions for three ultraluminous infrared galaxies

    Get PDF
    We present HST Faint Object Camera ultraviolet (230 nm and 140 nm) images of three ultraluminous infrared galaxies (ULIG: L_ir > 10^12 L_sun) selected from the IRAS Revised Bright Galaxy Sample. The purpose is to estimate spectral energy distributions (SEDs) to facilitate the identification of similar objects at high redshift in deep optical, infrared, and submm surveys. All three galaxies (VII Zw031 = IRAS F12112+0305, and IRAS F22491-1808) were well detected at 230 nm. Two of the three were marginally detected at 140 nm. The fluxes, together with ground-based optical and infrared photometry, are used to compute SEDs over a wide wavelength range. The measured SEDs drop from the optical to the ultraviolet, but the magnitude of the drop ranges from a factor of ~3 in IRAS F22491-1808 to a factor of ~100 in VIIZw031. This is most likely due to different internal extinctions. Such an interpretation is also suggested by extrapolating to ultraviolet wavelengths the optical internal extinction measured in VIIZw031. K-corrections are calculated to determine the colors of the sample galaxies as seen at high redshifts. Galaxies like VIIZw031 have very low observed rest-frame UV fluxes which means that such galaxies at high redshift will be extremely red or even missing in optical surveys. On the other hand, galaxies like IRAS F12112+0305 and IRAS F22491-1808, if seen at high redshift, would be sufficiently blue that they would not easily be distinguished from normal field galaxies, and therefore, identified as ULIGs. The implication is then that submillimeter surveys may be the only means of properly identifying the majority of ULIGs at high redshift.Comment: AJ in press, TeX, 23 pages, 7 tab, 17 figs available also (at higher resolution) from http://www.ast.cam.ac.uk~trentham/ufigs.htm
    • 

    corecore