54 research outputs found

    Comparison of a Head Mounted Impact Measurement Device to the Hybrid III Anthropomorphic Testing Device in a Controlled Laboratory Setting

    Get PDF
    Background: Reports estimate that 1.6 to 3.8 million cases of concussion occur in sports and recreation each year in the United States. Despite continued efforts to reduce the occurrence of concussion, the rate of diagnosis continues to increase. The mechanisms of concussion are thought to involve linear and rotational head accelerations and velocities. One method of quantifying the kinematics experienced during sport participation is to place measurement devices into the athlete’s helmet or directly on the athlete’s head. Purpose: The purpose of this research to determine the accuracy of a head mounted device for measuring the head accelerations experienced by the wearer. This will be accomplished by identifying the error in Peak Linear Acceleration (PLA), Peak Rotational Acceleration (PRA) and Peak Rotational Velocity (PRV) of the device. Study Design: Laboratory study. Methods: A helmeted Hybrid III 50th percentile male headform was impacted via a pneumatic ram from the front, side, rear, front oblique and rear oblique at speeds from 1.5 to 5 m/s. The X2 Biosystems xPatch® (Seattle, WA) sensor was placed on the headform’s right side at the approximate location of the mastoid process. Measures of PLA, PRA, PRV from the xPatch ® and Hybrid III were analyzed for Root Mean Square Error (RMSE), and Absolute and Relative Error (AE, RE). Result: Seventy-six impacts were analyzed. All measures of correlation, fixed through the origin, were found to be strong: PLA R2 =0.967 p \u3c 0.01, PRA R2 =0.933 p \u3c 0.01, PRV R2 =0.999 p \u3c 0.00. PLA RMSE was 34%, RE 31.0% ± 14.0, and AE 31.1% ± 13.7. PRA RMSE was 23.4%, RE -6.7 ± 22.4 and AE 18.9% ± 13.8. PRV RMSE was 2.2%, RE 0.1 ± 2.2, and AE 1.8 ± 1.3. Conclusion: Without including corrections for effect of skin artifact, the xPatch® produces measurements highly correlated with the gold standard yet above the average error of testing devices in both PLA and PRA, but a low error in PRV. PLA measures from the xPatch® system demonstrated a high level of correlation with the PLA data from the Hybrid III mounted data collection system. Level of Evidence:

    Simulation of Occupant Response in Space Capsule Landing Configurations With Suit Hardware

    Get PDF
    The purpose of this study was to compare the response of the total human model for safety (THUMS) human body finite element model (FEM) to experimental postmortem human subject (PMHS) test results and evaluate possible injuries caused by suit ring elements. Experimental testing evaluated the PMHS response in frontal, rear, side, falling, and spinal impacts. The THUMS was seated in a rigid seat that mirrored the sled buck used in the experimental testing. The model was then fitted with experimental combinations of neck, shoulder, humerus and thigh rings with a five-point restraint system. Experimental seat acceleration data was used as the input for the simulations. The simulation results were analyzed and compared to PMHS measurements to evaluate the response of the THUMS in these loading conditions. The metrics selected to compare the THUMS simulation to PMHS tests were the chest acceleration, seat acceleration and belt forces with additional metrics implemented in THUMS. The chest acceleration of the simulations and the experimental data was closely matched except in the Z-axis (superior/inferior) loading scenarios based on signal analysis. The belt force data of the model better correlated to the experimental results in loading scenarios where the THUMS interacted primarily with the restraint system compared to load cases where the primary interaction was between the seat and the occupant (rear, spinal and lateral impacts). The simulation output demonstrated low injury metric values for the occupant in these loading conditions. In the experimental testing, rib fractures were recorded for the frontal and left lateral impact scenarios. Fractures were not seen in the simulations, most likely due to variations between the simulation and the PMHS initial configuration. The placement of the rings on the THUMS was optimal with symmetric placement about the centerline of the model. The experimental placement of the rings had more experimental variation. Even with this discrepancy, the THUMS can still be considered a valuable predictive tool for occupant injury because it can compare results across many simulations. The THUMS also has the ability to assess a wider variety of other injury information, compared to anthropomorphic test devices (ATDs), that can be used to compare simulation results

    Faecal metabolome and its determinants in inflammatory bowel disease

    Get PDF
    OBJECTIVE: Inflammatory bowel disease (IBD) is a multifactorial immune-mediated inflammatory disease of the intestine, comprising Crohn's disease and ulcerative colitis. By characterising metabolites in faeces, combined with faecal metagenomics, host genetics and clinical characteristics, we aimed to unravel metabolic alterations in IBD.DESIGN: We measured 1684 different faecal metabolites and 8 short-chain and branched-chain fatty acids in stool samples of 424 patients with IBD and 255 non-IBD controls. Regression analyses were used to compare concentrations of metabolites between cases and controls and determine the relationship between metabolites and each participant's lifestyle, clinical characteristics and gut microbiota composition. Moreover, genome-wide association analysis was conducted on faecal metabolite levels.RESULTS: We identified over 300 molecules that were differentially abundant in the faeces of patients with IBD. The ratio between a sphingolipid and L-urobilin could discriminate between IBD and non-IBD samples (AUC=0.85). We found changes in the bile acid pool in patients with dysbiotic microbial communities and a strong association between faecal metabolome and gut microbiota. For example, the abundance of Ruminococcus gnavus was positively associated with tryptamine levels. In addition, we found 158 associations between metabolites and dietary patterns, and polymorphisms near NAT2 strongly associated with coffee metabolism.CONCLUSION: In this large-scale analysis, we identified alterations in the metabolome of patients with IBD that are independent of commonly overlooked confounders such as diet and surgical history. Considering the influence of the microbiome on faecal metabolites, our results pave the way for future interventions targeting intestinal inflammation.</p

    Active Zone Protein Bassoon Co-Localizes with Presynaptic Calcium Channel, Modifies Channel Function, and Recovers from Aging Related Loss by Exercise

    Get PDF
    The P/Q-type voltage-dependent calcium channels (VDCCs) are essential for synaptic transmission at adult mammalian neuromuscular junctions (NMJs); however, the subsynaptic location of VDCCs relative to active zones in rodent NMJs, and the functional modification of VDCCs by the interaction with active zone protein Bassoon remain unknown. Here, we show that P/Q-type VDCCs distribute in a punctate pattern within the NMJ presynaptic terminals and align in three dimensions with Bassoon. This distribution pattern of P/Q-type VDCCs and Bassoon in NMJs is consistent with our previous study demonstrating the binding of VDCCs and Bassoon. In addition, we now show that the interaction between P/Q-type VDCCs and Bassoon significantly suppressed the inactivation property of P/Q-type VDCCs, suggesting that the Ca2+ influx may be augmented by Bassoon for efficient synaptic transmission at NMJs. However, presynaptic Bassoon level was significantly attenuated in aged rat NMJs, which suggests an attenuation of VDCC function due to a lack of this interaction between VDCC and Bassoon. Importantly, the decreased Bassoon level in aged NMJs was ameliorated by isometric strength training of muscles for two months. The training increased Bassoon immunoreactivity in NMJs without affecting synapse size. These results demonstrated that the P/Q-type VDCCs preferentially accumulate at NMJ active zones and play essential role in synaptic transmission in conjunction with the active zone protein Bassoon. This molecular mechanism becomes impaired by aging, which suggests altered synaptic function in aged NMJs. However, Bassoon level in aged NMJs can be improved by muscle exercise

    How protein targeting to primary plastids via the endomembrane system could have evolved? A new hypothesis based on phylogenetic studies

    Full text link

    A heel-strike real-time auditory feedback device to promote motor learning in children who have cerebral palsy: a pilot study to test device accuracy and feasibility to use a music and dance-based learning paradigm

    No full text
    Abstract Background Cerebral palsy (CP) is a developmental disorder of movement and posture that occurs due to damage to the developing nervous system. As part of therapy, wearable sensors that trigger interactive feedback may provide multi-sensory guidance and motivation. A prototype of a heel-strike real-time feedback system has been developed which records the number of heel strikes during gait and indicates successful heel contact through real-time auditory feedback. The first aim of this feasibility study was to test the prototype accuracy. Since the end user for this device is a child, the device should be esthetically appealing and sufficiently motivating for children to perform repetitive challenging therapeutic movements. The second aim of this study was to collect feedback from the subjects with regard to the device usability and understand if the bell sound used as feedback used was motivating enough for children to continue using the prototype. This would help us in developing the next generation of the device. Methods The prototype was tested with typically developing children and children who have CP. The accuracy in detecting heel strikes was calculated. As part of the study, the subjects were also asked questions to test the device compliance and acceptability of the musical beats with the pediatric population. Results The device accuracy in identifying heel strikes is 97.44% (95% CI 96.31, 98.88%). The subjects did not show any hesitation to put on the device and the sound feedback motivated them to move. Based on this pilot study, a minimum age limit of 5 years is appropriate and the intervention study should be conducted for no more than 30 min per week. Conclusions The pilot study showed that a main study can be conducted to test auditory feedback as an intervention to promote motor learning in children who have cerebral palsy. No adverse event or safety issues were reported in the feasibility study

    Atrophy of gluteus maximus among women with a history of chronic low back pain.

    Get PDF
    Although the relationship between low back pain (LBP) and the size of certain trunk muscles has been extensively studied, the relationship between gluteus maximus (GM) size and LBP has been only minimally examined. Determining whether such a relationship exists would help improve our understanding of the etiology of LBP, and possibly provide a rationale for the use of therapeutic exercise interventions targeting GM with LBP patients. The objective of this study was to compare gluteus maximus cross-sectional area in individuals with chronic LBP, and in a group of individuals without LBP. Our hypothesis was that individuals with LBP would have greater atrophy in their gluteus maximus muscles than our control group.For this case-control study, we analyzed medical history and pelvic computed tomography (CT) scans for 36 female patients with a history of chronic LBP, and 32 female patients without a history of LBP. Muscle cross-sectional area of gluteus maximus was measured from axial CT scans using OsiriX MD software, then was normalized to patient height, and used to compare the two groups. The number of back pain-related medical visits was also correlated with gluteus maximus cross-sectional area.Mean normalized cross-sectional area was significantly smaller in the LBP group than in the control group, with t = 2.439 and P<0.05. The number of back pain-related visits was found to be significantly correlated with normalized cross-sectional area, with r = -0.270 and P<0.05. The atrophy seen in the present research may reflect incidental disuse atrophy seen with LBP, which is present in many muscle groups after prolonged immobilization or with a sedentary lifestyle.This research demonstrated a previously only minimally explored relationship between gluteus maximus cross-sectional area and LBP in women. Further research is indicated in individuals with varying age, sex, and LBP diagnoses

    Gluteus maximus cross-sectional area measurements in patients with and without chronic low back pain.

    No full text
    <p>Gluteus maximus cross-sectional area measurements in patients with and without chronic low back pain.</p

    ICD-9 codes for chronic low back pain sample.

    No full text
    <p>ICD-9 codes for chronic low back pain sample.</p

    Sampling methodology.

    No full text
    <p>Sampling methodology.</p
    • …
    corecore