330 research outputs found

    Detailed theoretical models for extra-solar planet-host stars: The "red stragglers" HD37124 and HD46375

    Full text link
    In this paper we analyse and discuss the HR Diagram position of two extra-solar planet-host stars - HD37124 and HD46375 - by means of theoretical stellar evolution models. This work was triggered by the results obtained by Laws et al. (2003) who found that these stars were in contradiction to the expectation based on their high metallicity. Fixing the age of both stars with the value based on their chromospheric activity levels and computing our own evolutionary models using the CESAM code, we are able to reproduce the observed luminosity, effective temperature and metallicity of both stars for a set of stellar parameters that are astrophysically reliable even if it is non-trivial to interpret the absolute values for these parameters. Our results are discussed in the context of the stellar properties of low mass stars.Comment: 6 pages, 2 figures, A&A, in pres

    Improved vehicle-to-home (iV2H) operation mode: experimental analysis of the electric vehicle as off-line UPS

    Get PDF
    This paper presents experimental results of electric vehicle (EV) operation as an off-line uninterruptible power supply (UPS). Besides the traditional grid-to-vehicle and vehicle-to-grid modes, this paper presents an improved vehicle-to-home operation mode. This new operation mode consists of the detection of a power outage in the power grid and the change of the EV battery charger control to operate as an off-line UPS. When the power grid voltage is restored, the voltage produced by the on-board EV battery charger is slowly synchronized with the power grid voltage before a complete transition to the normal mode. This paper presents results of two algorithms to detect a power outage: the root mean square (rms) calculation method based on half-cycle of the power grid voltage, and the rms estimation based on a Kalman filter. The experimental results were obtained in steady and transient state considering two cases with the EV plugged in at home:when charging the batteries and without charging the batteries. This paper describes the EV battery charger, the power outage detection methods, and the voltage and current control strategies.- This work was supported by the Fundacao para a Ciencia e Tecnologia (FCT) in the scope of the projects under Grant PEst-UID/CEC/00319/2013. The work of V. Monteiro was supported by the Doctoral Scholarship through the Portuguese FCT Agency under Grant SFRH/BD/80155/2011. The work of B. Exposto was supported by the Doctoral Scholarship through the Portuguese FCT Agency under Grant SFRH/BD/87999/2012.info:eu-repo/semantics/publishedVersio

    Target Selection in Multistatic Microwave Breast Imaging Setup Using Dielectric Lens

    Get PDF
    Microwave Imaging (MWI) has been studied to aid early breast cancer detection. Current prototypes in more advanced stages of development include both monostatic or multistatic setups. However, multistatic configurations usually include a high number of antennas which consequently require complex and computationally-intensive signal processing algorithms to ensure a good target detection. We previously presented a novel approach using a dielectric lens which reduces the signal processing burden of multistatic setups, while ensuring good spatial resolution. In this paper, we evaluate this novel setup using an anatomically realistic breast phantom and its capability of selecting targets inside the breast. We show a successful detection of the targets using an artefact removal algorithm based on singular value decomposition when the Bessel beam is centered at the target location.info:eu-repo/semantics/publishedVersio

    Study of the Refraction Effects in Microwave Breast Imaging Using a Dry Setup

    Get PDF
    Medical Microwave Imaging (MWI) has been studied as a technique to aid breast cancer diagnosis. Several different prototypes have been proposed but most of them require the use of a coupling medium between the antennas and the breast, in order to reduce skin backscattering and avoid refraction effects. The use of dry setups has been addressed and recent publications show promising results. In this paper, we assess the importance of considering refraction effects in the image reconstruction algorithms. To this end, we consider a simplified homogeneous spherical model of the breast and analytically compute the propagating rays through the air-body interface. The comparison of results considering only direct ray propagation or refracted rays shows negligible impact on the accuracy of the images for moderately high permittivity media. Thus, we may avoid the computational burden of calculating the refracted rays in complex shapes.info:eu-repo/semantics/publishedVersio

    Evaluation of Refraction Effects in Dry Medical Microwave Imaging Setups

    Get PDF
    Dry microwave imaging (MWI) systems are more practical, hygienic, and fast to operate since they do not require immersion liquid. However, the dielectric contrast between air and the part of the body under examination is larger, causing larger refraction effects. Including refraction in the image reconstruction algorithm significantly increases the computational effort, especially when imaging nonuniform shapes. Hence, our systematic study aims to evaluate the impact of neglecting refraction effects on MWI by using quantitative metrics and define objective guidelines that are lacking in the literature. We perform comparative studies with a spherical numerical phantom (which is typically used to represent simplified breast or head phantoms) by varying the phantom relative permittivity values between 4 and 40, metallic targets diameter between 5 and 15 mm, and the number of probing antennas. Additionally, the refraction effects are evaluated with anthropomorphic body phantoms representing a breast and the axillary region. We numerically and experimentally show that refraction tends to have a greater impact on imaging results when phantom relative permittivity values exceed 8, while it has a minor effect in the remaining tested cases. This favors potential fast real-time image reconstruction. This letter provides useful criteria to decide whether refraction should be considered or not for imaging reconstruction when developing new dry medical MWI setups.info:eu-repo/semantics/publishedVersio

    Experimental Evaluation of an Axillary Microwave Imaging System to Aid Breast Cancer Staging

    Get PDF
    The number of metastasised Axillary Lymph Nodes (ALNs) is a key indicator for breast cancer staging. Its correct assessment affects subsequent therapeutic decisions. Common ALN screening modalities lack high enough sensitivity and specificity. Level I ALNs produce detectable backscattering of microwaves, opening the way for Microwave Imaging (MWI) as a complementary screening modality. Radar-based MWI is a low-cost, noninvasive technique, widely studied for breast cancer and brain stroke detection. However, new specific challenges arise for ALN detection, which deter a simple extension of existing MWI methods. The geometry of the axillary region is more complex, limiting the antenna travel range required for maximum resolution. Additionally, unlike breast MWI setups, it is impractical to use liquid immersion to enhance energy coupling to the body; therefore, higher skin reflection masks ALNs response. We present a complete study that proposes dedicated imaging algorithms to detect ALNs dealing with the above constraints, and evaluate their effectiveness experimentally. We describe the developed setup based on a 3D-printed anthropomorphic phantom, and the antenna-positioning configuration. To the authors’ knowledge, this is the first ALN-MWI study involving a fully functional anatomically compliant setup. A Vivaldi antenna, operating in a monostatic radar mode at 2-5 GHz, scans the axillary region. Pre-clinical assessment in different representative scenarios shows Signal-to-ClutterRatio higher than 2.8 dB and Location Error lower than 15mm, which is smaller than considered ALN dimensions. Our study shows promising level I ALN detection results despite the new challenges, confirming MWI potential to aid breast cancer staging.info:eu-repo/semantics/publishedVersio

    Feasibility study of focal lens for multistatic microwave breast imaging

    Get PDF
    Microwave Imaging is an emerging technique to aid breast cancer diagnosis. Current multistatic setups involve complex and heavy signal processing techniques, such as to remove the energy coupling between adjacent sensors, which masks the response from inner tissues. We investigate a novel approach using a dielectric lens in order to reduce the coupling effects between antennas, thus reducing the signal processing burden, while preserving all the advantages of multistatic setups. In this paper, we show that we can successfully detect simulated breast targets on reconstructed images using a setup with a dielectric lens.info:eu-repo/semantics/publishedVersio

    Optimisation of Artefact Removal Algorithm for Microwave Imaging of the Axillary Region Using Experimental Prototype Signals

    Get PDF
    Microwave Imaging (MWI) has the potential to aid breast cancer staging through the detection of Axillary Lymph Nodes (ALNs). This type of system can present some challenges, mainly due to the irregular axillary surface. The optimisation of the artefact removal algorithm to successfully remove the surface reflections is of great importance. In this paper, we propose using Singular Value Decomposition (SVD) as an artefact removal algorithm and study the effect of choosing different subsets of antenna positions for artefact removal on imaging results using experimental signals. We show that different subsets of antenna positions affect the results and in some cases prevent the targets detection. Our analysis allowed us to find an optimal combination of parameters which results in Signal-to-Clutter Ratio higher than 2.77 dB and Location Error lower than 14.9 mm for three different experimental tests. These results are relevant for the development of dedicated algorithms for ALN-MWI application.info:eu-repo/semantics/publishedVersio

    Study of Freezing and Defrosting Effects on Complex Permittivity of Biological Tissues

    Get PDF
    In this letter we study the effect of freezing and defrosting on the dielectric properties of biological tissues. The electromagnetic characterization of tissues at microwave frequencies is crucial for the development of microwave-based biomedical devices. These measurements are often not practical, as tissue degradation restricts the time available between tissue excision and dielectric measurements. For this reason, measurement of tissues that underwent freezing and defrosting may provide researchers with more flexibility in setting measurement campaigns, thus speeding up the development of microwave-based biomedical devices. To this end, this letter presents dielectric measurement on frozen and defrosted tissue, which translates into the following objectives: first, investigate if the dielectric properties of defrosted tissues depend on frozen storage time; second, determine if defrosted tissue dielectric properties differ from those of fresh tissues. As a result, we measure the dielectric properties of ten samples of chicken muscle, bovine liver, and bovine fat, each before and after freezing (up to 14 days) and defrosting. The measurements are performed with the open-ended coaxial probe method at the frequency band of 0.5–8.5 GHz. We observe a slight increase—less than 10%—in complex permittivity of high-water-content tissues (muscle and liver) after defrosting, and negligible effect on fat tissues.info:eu-repo/semantics/acceptedVersio

    Effect of Varying Prior Information in Axillary 2D Microwave Tomography

    Get PDF
    We numerically assess the potential of microwave tomography (MWT) for the detection and dielectric properties estimation of axillary lymph nodes (ALNs), and we study the robustness of our system using prior information with varying levels of accuracy. We adopt a 2-dimensional MWT system with 8 antennas (0.5-2.5 GHz) placed around the axillary region. The reconstruction algorithm implements the distorted Born iterative method. We show that: (i) when accurate prior knowledge of the axillary tissues (fat and muscle) is available, our system successfully detects an ALN; (ii) ±30% error in the prior estimation of fat and muscle dielectric properties does not affect image quality; (iii) ±7mm error in muscle position causes slight artifacts, while ± 14mm error in muscle position affects ALN detection. To the best of our knowledge, this is the first paper in the literature to study the impact of prior information accuracy on detecting an ALN using MWT.info:eu-repo/semantics/publishedVersio
    • …
    corecore