35 research outputs found

    Validation of the Rome III criteria and alarm symptoms for recurrent abdominal pain in children

    No full text
    Rome criteria were formulated to define functional gastrointestinal disorders (Rome III criteria, 2006) excluding organic diagnoses when alarm symptoms were absent. The aims of the study were to validate the Rome III criteria as to their capacity to differentiate between organic and functional abdominal pain and to assess the role of alarm symptoms in this differentiation. During 2 years all of the patients (ages 4-16 years) presenting with recurrent abdominal pain (Apley criteria) and referred to secondary care were included. Clinical diagnoses were based on protocolized evaluation and intervention with 6-month follow-up. Alarm symptoms were registered. Rome III criteria for functional pain syndromes were assigned independently. Descriptive statistical analyses were performed. In 200 patients (87 boys, mean age 8.8 years), organic (17%), functional (40%), combined organic and functional (9%), spontaneous recovery (27%), and other (8%) clinical diagnoses were established. Alarm symptoms were found in 57.5% (organic causes 56%, functional causes 61%). The evaluation for Rome symptom clusters revealed symptoms of irritable bowel syndrome in 27%, functional dyspepsia in 15%, functional abdominal pain in 28%, functional abdominal pain syndrome in 14.5%, and no pain syndrome in 15.5%. Rome diagnoses, based on symptoms and absence of alarm symptoms, predicted functional clinical diagnosis with sensitivity 0.35 (95% confidence interval 0.27-0.43), specificity 0.60 (0.46-0.73), positive predictive value 0.71 (0.61-0.82), and negative predictive value of 0.24 (0.17-0.32). The Rome III criteria for abdominal pain are not specific enough to rule out organic causes. Alarm symptoms do not differentiate between organic and functional abdominal pai

    Is mid-upper arm circumference in Dutch children useful in identifying obesity?

    No full text
    Background Mid-upper arm circumference (MUAC) is suggested as being a valid measure in detecting overweight/obesity in children and adolescents, due to the strong relation with weight. We examined this relation and compared MUAC to body mass index (BMI) according to the International Obesity Task Force (IOTF) in children. Methods Anthropometric data including MUAC were collected in 2009 by trained healthcare professionals in the context of the fifth Dutch Nationwide Growth Study, in a sample of 6167 children (2891 boys and 3276 girls) aged 2-18 years of Dutch origin. We propose MUAC SDS cut-off values for overweight and obesity, and compared MUAC with BMI IOTF in sex-specific and age-specific categories (2-5, 6-11, 12-18 years). Results The area under the curve is used as a measure of diagnostic accuracy; the explained variance (R) is good to excellent (0.88-0.94). Sensitivity ranges from 51.8% to 95.3% and specificity from 71.4% to 93.8%. Across age and gender groups, 65.1% to 89.0% participants are classified by both MUAC and BMI as normal weight, overweight or obese. We constructed three equations to predict weight using MUAC, with small differences between observed and predicted weight with an explained variance ranging from 0.88 to 0.94. Conclusions Compared with BMI, MUAC is a valid measure for detecting overweight and obesity and thus a good alternative for BMI. When weight has to be estimated, it can be accurately predicted using MUAC. Based on our observations, we recommend developing diagrams with international (IOTF) cut-offs for MUAC SDS similar to BMI

    Is mid-upper arm circumference in Dutch children useful in identifying obesity?

    No full text
    Background Mid-upper arm circumference (MUAC) is suggested as being a valid measure in detecting overweight/obesity in children and adolescents, due to the strong relation with weight. We examined this relation and compared MUAC to body mass index (BMI) according to the International Obesity Task Force (IOTF) in children. Methods Anthropometric data including MUAC were collected in 2009 by trained healthcare professionals in the context of the fifth Dutch Nationwide Growth Study, in a sample of 6167 children (2891 boys and 3276 girls) aged 2-18 years of Dutch origin. We propose MUAC SDS cut-off values for overweight and obesity, and compared MUAC with BMI IOTF in sex-specific and age-specific categories (2-5, 6-11, 12-18 years). Results The area under the curve is used as a measure of diagnostic accuracy; the explained variance (R) is good to excellent (0.88-0.94). Sensitivity ranges from 51.8% to 95.3% and specificity from 71.4% to 93.8%. Across age and gender groups, 65.1% to 89.0% participants are classified by both MUAC and BMI as normal weight, overweight or obese. We constructed three equations to predict weight using MUAC, with small differences between observed and predicted weight with an explained variance ranging from 0.88 to 0.94. Conclusions Compared with BMI, MUAC is a valid measure for detecting overweight and obesity and thus a good alternative for BMI. When weight has to be estimated, it can be accurately predicted using MUAC. Based on our observations, we recommend developing diagrams with international (IOTF) cut-offs for MUAC SDS similar to BMI

    Is mid-upper arm circumference in Dutch children useful in identifying obesity?

    No full text
    Background Mid-upper arm circumference (MUAC) is suggested as being a valid measure in detecting overweight/obesity in children and adolescents, due to the strong relation with weight. We examined this relation and compared MUAC to body mass index (BMI) according to the International Obesity Task Force (IOTF) in children. Methods Anthropometric data including MUAC were collected in 2009 by trained healthcare professionals in the context of the fifth Dutch Nationwide Growth Study, in a sample of 6167 children (2891 boys and 3276 girls) aged 2-18 years of Dutch origin. We propose MUAC SDS cut-off values for overweight and obesity, and compared MUAC with BMI IOTF in sex-specific and age-specific categories (2-5, 6-11, 12-18 years). Results The area under the curve is used as a measure of diagnostic accuracy; the explained variance (R) is good to excellent (0.88-0.94). Sensitivity ranges from 51.8% to 95.3% and specificity from 71.4% to 93.8%. Across age and gender groups, 65.1% to 89.0% participants are classified by both MUAC and BMI as normal weight, overweight or obese. We constructed three equations to predict weight using MUAC, with small differences between observed and predicted weight with an explained variance ranging from 0.88 to 0.94. Conclusions Compared with BMI, MUAC is a valid measure for detecting overweight and obesity and thus a good alternative for BMI. When weight has to be estimated, it can be accurately predicted using MUAC. Based on our observations, we recommend developing diagrams with international (IOTF) cut-offs for MUAC SDS similar to BMI

    Iron Deficiency in Inflammatory Bowel Disease: The Use of Zincprotoporphyrin and Red Blood Cell Distribution Width

    No full text
    Objectives: Iron deficiency (ID) in children with inflammatory bowel disease (IBD) is either an absolute (depleted iron stores) or a functional deficiency (caused by chronic inflammation). Differentiating between these 2 types of ID is important because they require a different therapeutic approach. Zinc protoporphyrin (ZPP) and red blood cell distribution width (RDW) are parameters of functional ID. Studies using these parameters to differentiate are nonexistent. We aimed to evaluate the prevalence of and risk factors for absolute and functional ID in paediatric IBD patients while using ZPP and RDW. Methods: We evaluated the iron status and medical charts of 59 paediatric IBD patients in a secondary hospital in the Netherlands. Absolute ID was defined as serum ferritin 70 mu mol/mol haem and/or an RDW >14%. Anaemia of chronic disease (ACD) was defined as functional ID in combination with anaemia. Results: Absolute and functional ID were found in 19/59 (32.2%) and 32/40 (80%) patients, respectively. The prevalence of IDA and ACD was 27.1% (16/59) and 20%(8/40), respectively. Multivariate analyses showed that absolute ID and IDA were both associated with a more recent IBD-diagnosis (both P <0.05). Conclusions: Absolute and functional ID are common in paediatric IBD patients, and this differentiation is important because of therapeutic consequences. Furthermore, absolute ID and IDA are associated with a more recent IBD-diagnosi

    Pyruvate kinase deficiency associated with severe liver dysfunction in the newborn

    No full text
    Significant hyperbilirubinaemia, anemia, and splenomegaly are common features in patients with severe haemolysis due to pyruvate kinase (PK) deficiency. Until now, severe neonatal PK deficiency has not been associated with fatal liver disease at this age. We present two neonatal cases of severe PK deficiency complicated with progressive fatal liver disease. The patients presented with severe haemolysis, progressive cholestasis, and hepatosplenomegaly, and both patients ultimately developed liver failure at a very young age. Despite extensive investigations, no specific explanation for liver disease and failure was found. We suggest that the PK deficiency itself directly led to liver dysfunctio

    Organic and perovskite solar modules innovated by adhesive top electrode and depth-resolved laser patterning

    No full text
    We demonstrate an innovative solution-processing fabrication route for organic and perovskite solar modules via depth-selective laser patterning of an adhesive top electrode. This yields unprecedented power conversion efficiencies of up to 5.3% and 9.8%, respectively. We employ a PEDOT:PSS–Ag nanowire composite electrode and depth-resolved post-patterning through beforehand laminated devices using ultra-fast laser scribing. This process affords low-loss interconnects of consecutive solar cells while overcoming typical alignment constraints. Our strategy informs a highly simplified and universal approach for solar module fabrication that could be extended to other thin-film photovoltaic technologies
    corecore