33 research outputs found
Ultra-sensitive carbon based molecular sensors
This thesis presented the study of carbon-based materials for ultra-sensitive molecular sensing.
Reduced Graphene Oxide (rGO), a 2-dimensional one-atomic layer thick carbon material, had the advantage of low-cost, aqueous and industrial-scalable production route. Using rGO as the transducer platform could potentially lower the cost of sensors down to a few dollars per chip. However, there were still limitations in rGO that prevented its widespread usage as a biosensor transducer or in electronics: its low electrical conductivity and large electrical deviations. This thesis was structured to understand and solve these problems for transducer application. The thesis could be broken down into 3 parts:
The first part of the thesis presented the critical review of the background and limitations of graphene research, followed by the background and importance of biosensor developments for the detection of sweat sodium ions and circulatory Interleukin-6 proteins.
The second part of the thesis tested the hypothesis that the rGO limitations could be eliminated to create a highly sensitive biosensor transducer via (A) improving rGO synthesis (B) pristine Carbon Nanotubes-rGO hybrid film and (C) growth of rGO. The mechanism of ultra-large graphene oxide synthesis and graphene oxide growth was also elucidated in this section.
The third part of the thesis then presented the fabrication and test of the practical and homogenous carbon-based biosensor using the transducer synthesized earlier. The thesis showed that through proving the hypothesis correct, it enabled the synthesis of an all organic sodium ion sensor with integrated pump and an ultra-sensitive interleukin-6 bio-sensor. Both of these novel sensors were able to detect the respective molecules in their physiological ranges
A review on electronic bio-sensing approaches based on non-antibody recognition elements
In this review, recent advances in the development of electronic detection methodologies based on non-antibody recognition elements such as functional liposomes, aptamers and synthetic peptides are discussed. Particularly, we highlight the progress of field effect transistor (FET) sensing platforms where possible as the number of publications on FET-based platforms has increased rapidly. Biosensors involving antibody-antigen interactions have been widely applied in diagnostics and healthcare in virtue of their superior selectivity and sensitivity, which can be attributed to their high binding affinity and extraordinary specificity, respectively. However, antibodies typically suffer from fragile and complicated functional structures, large molecular size and sophisticated preparation approaches (resource-intensive and time-consuming), resulting in limitations such as short shelf-life, insufficient stability and poor reproducibility. Recently, bio-sensing approaches based on synthetic elements have been intensively explored. In contrast to existing reports, this review provides a comprehensive overview of recent advances in the development of biosensors utilizing synthetic recognition elements and a detailed comparison of their assay performances. Therefore, this review would serve as a good summary of the efforts for the development of electronic bio-sensing approaches involving synthetic recognition elements
The extended growth of graphene oxide flakes using ethanol CVD
We report the extended growth of Graphene Oxide (GO) flakes using atmospheric pressure ethanol Chemical Vapor Deposition (CVD).
GO was used to catalyze the deposition of carbon on substrate in the ethanol CVD with Ar and H2 as carrier gases. Raman, SEM, XPS
10 and AFM characterized the growth to be reduced GO (RGO) of <5 layers. This new grown RGO possesses lower defect density with
larger and increased distribution of sp2 domains than chemically-reduced RGO. Furthermore this method without optimization reduces
relative standard deviation of electrical conductivity between chips, from 80.5% to 16.5%, enabling RGO to be used in practical
electronic devices
The detection and measurement of interleukin-6 in venous and capillary blood samples, and in sweat collected at rest and during exercise
Purpose:
This study aimed to quantify the relationship between venous and capillary blood sampling methods for the measurement of plasma interleukin-6 (IL-6). A parallel study was conducted to determine the possibility of measuring IL-6 in sweat using an enzyme-linked immunosorbent assay (ELISA) and investigate the relationship between plasma- and sweat-derived measures of IL-6.
Methods:
Twelve male participants were recruited for the measurement of IL-6 at rest and during exercise (study 1). An additional group of five female participants was recruited for the measurement of IL-6 in venous blood versus sweat at rest and following exercise (study 2). In study 1, venous and capillary blood samples were collected at rest and in response to exercise. In study 2, venous and sweat samples were collected following exercise.
Results:
Mean plasma IL-6 concentration was not different between venous and capillary blood sampling methods either at rest (4.27 ± 5.40 vs. 4.14 ± 4.45 pg ml−1), during (5.40 ± 5.17 vs. 5.58 ± 6.34 pg ml−1), or in response to exercise (6.95 ± 6.37 vs. 6.99 ± 6.74 pg ml−1). There was no IL-6 detectable in sweat either at rest or following exercise.
Conclusion:
There are no differences in the measurement of plasma IL-6 using either venous or capillary blood sampling methods. Capillary measurement represents a minimally invasive way of measuring IL-6 and detecting changes in IL-6, which are linked to fatigue and overtraining
Detection of matrilysin (MMP-7) activity using polypeptide functionalized reduced graphene oxide field-effect transistor sensor.
A novel approach for rapid and sensitive detection of matrilysin (MMP-7, a biomarker involved in the degradation of vari-ous macromolecules) based on polypeptide (JR2EC) functionalized reduced graphene oxide (rGO) field effect transistor (FET) is reported. MMP-7 specifically digests negatively charged JR2EC immobilized on rGO, thereby modulating the con-ductance of rGO-FET. The proposed assay enabled detection of MMP-7 at clinically relevant concentrations with a limit of detection (LOD) of 10 ng/mL (400 pM), attributed to the significant reduction of the net charge of JR2EC upon digestion by MMP-7. Quantitative detection of MMP-7 in human plasma was further demonstrated with a LOD of 40 ng/mL, illustrating the potential for the proposed methodology for tumor detection and carcinoma diagnostic (e.g. lung cancer and salivary gland cancer). Additionally, excellent specificity of the proposed assay was demonstrated using matrix metallopeptidase 1 (MMP-1), a protease of the same family. With appropriate selection and modification of polypeptides, the proposed assay could be extended for detections of other enzymes with polypeptide digestion capability
Observed versus predicted yields of rice (kg/ha) for the provinces of Heilongjiang (HLJ), Hunan (HN), Jiangxi (JX), Sichuan (SC) and Guangxi (GX) over the period 1982–2004.
<p>Observed versus predicted yields of rice (kg/ha) for the provinces of Heilongjiang (HLJ), Hunan (HN), Jiangxi (JX), Sichuan (SC) and Guangxi (GX) over the period 1982–2004.</p
The locations of the study areas within Mainland China.
<p>Heilongjiang is designated by HLJ, Jiangxi by JX, Guangxi by GX, Sichuan by SC, and Hunan by HN.</p
Correlation coefficient (R) between the remotely sensed yields and NDVI variables during the rice growth period.
*<p>significant at 0.05 level; ** significant at 0.01 level, n = 23.</p
Relevant literatures that linked with crop yield forecast using remotely sensed data literatures are sorted according to the crop types.
<p>Relevant literatures that linked with crop yield forecast using remotely sensed data literatures are sorted according to the crop types.</p
Planted area and production changes for rice between 1979 and 2009 for different regions in the conterminous China.
<p>Planted area and production changes for rice between 1979 and 2009 for different regions in the conterminous China.</p