12 research outputs found

    Open Reduction of Subcondylar Fractures Using a New Retractor

    Get PDF
    Many operative approaches have been described for the open reduction of subcondylar fractures and rigid fixation. However, fracture portions are deep and embedded among facial nerves so that visual surgery in this region is extremely limited. Once the operative field is exposed, the displacement of the condylar head is often dislocated by the anteromedial pull of the lateral pterygoid muscle and the fracture end of the condylar process is pulled up to the mandibular fossa by contraction of the masseter muscle. We made a new retractor to achieve a better field of view. It is possible to pull down the condylar process by opening the tips of the retractor using the specially made wrench system without special effort and keep the condylar process in the same position during reduction. In using this retractor, the fracture stumps were clearly exposed and more easily reposited

    National trends in the outcomes of subarachnoid haemorrhage and the prognostic influence of stroke centre capability in Japan: retrospective cohort study

    No full text
    Objectives To examine the national, 6-year trends in in-hospital clinical outcomes of patients with subarachnoid haemorrhage (SAH) who underwent clipping or coiling and the prognostic influence of temporal trends in the Comprehensive Stroke Center (CSC) capabilities on patient outcomes in Japan.Design Retrospective study.Setting Six hundred and thirty-one primary care institutions in Japan.Participants Forty-five thousand and eleven patients with SAH who were urgently hospitalised, identified using the J-ASPECT Diagnosis Procedure Combination database.Primary and secondary outcome measures Annual number of patients with SAH who remained untreated, or who received clipping or coiling, in-hospital mortality and poor functional outcomes (modified Rankin Scale: 3–6) at discharge. Each CSC was assessed using a validated scoring system (CSC score: 1–25 points).Results In the overall cohort, in-hospital mortality decreased (year for trend, OR (95% CI): 0.97 (0.96 to 0.99)), while the proportion of poor functional outcomes remained unchanged (1.00 (0.98 to 1.02)). The proportion of patients who underwent clipping gradually decreased from 46.6% to 38.5%, while that of those who received coiling and those left untreated gradually increased from 16.9% to 22.6% and 35.4% to 38%, respectively. In-hospital mortality of coiled (0.94 (0.89 to 0.98)) and untreated (0.93 (0.90 to 0.96)) patients decreased, whereas that of clipped patients remained stable. CSC score improvement was associated with increased use of coiling (per 1-point increase, 1.14 (1.08 to 1.20)) but not with short-term patient outcomes regardless of treatment modality.Conclusions The 6-year trends indicated lower in-hospital mortality for patients with SAH (attributable to better outcomes), increased use of coiling and multidisciplinary care for untreated patients. Further increasing CSC capabilities may improve overall outcomes, mainly by increasing the use of coiling. Additional studies are necessary to determine the effect of confounders such as aneurysm complexity on outcomes of clipped patients in the modern endovascular era

    ILC Reference Design Report Volume 1 - Executive Summary

    No full text
    The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization

    ILC Reference Design Report Volume 4 - Detectors

    No full text
    This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics.This report, Volume IV of the International Linear Collider Reference Design Report, describes the detectors which will record and measure the charged and neutral particles produced in the ILC's high energy e+e- collisions. The physics of the ILC, and the environment of the machine-detector interface, pose new challenges for detector design. Several conceptual designs for the detector promise the needed performance, and ongoing detector R&D is addressing the outstanding technological issues. Two such detectors, operating in push-pull mode, perfectly instrument the ILC interaction region, and access the full potential of ILC physics
    corecore