9 research outputs found

    Ultrasound enhanced prehospital thrombolysis using microbubbles infusion in patients with acute ST elevation myocardial infarction: Rationale and design of the Sonolysis study

    Get PDF
    Contains fulltext : 70525.pdf (publisher's version ) (Open Access)ABSTRACT: BACKGROUND -: Experimental studies have shown that ultrasound contrast agents enhance the effectiveness of thrombolytic agents in the presence of ultrasound in vitro and in vivo. Recently, we have launched a clinical pilot study, called "Sonolysis", to study this effect in patients with ST-elevation myocardial infarction based on proximal lesions of the infarct-related artery. METHODS/DESIGN -: In our multicenter, randomized, placebo controlled clinical trial we will include patients between 18 and 80 years of age with their first ST-elevation myocardial infarction based on a proximal lesion of the infarct-related artery. After receiving a single bolus alteplase 50 mg IV (Actilyse(R) Boehringer Ingelheim GmbH), a loading dose of aspirin 500 mg, and heparin 5000 IU in the ambulance according to the prehospital thrombolysis protocol, patients, following oral informed consent, are randomized to undergo 15 minutes of pulsatile ultrasound with intravenous administration of ultrasound contrast agent or placebo without ultrasound. Afterwards coronary angiography and, if indicated, percutaneous coronary intervention will take place. A total of 60 patients will be enrolled in approximately 1 year.The primary endpoints are based on the coronary angiogram and consist of TIMI flow, corrected TIMI frame count, and myocardial blush grade. Follow-up includes 12-lead ECG, 2D-echocardiography, cardiac MRI, and enzyme markers to obtain our secondary endpoints, including the infarct size, wall motion abnormalities, and the global left ventricular function. DISCUSSION -: The Sonolysis study is the first multicenter, randomized, placebo controlled clinical trial investigating the therapeutic application of ultrasound and microbubbles in acute ST-elevation myocardial infarction patients. A positive finding may stimulate further research and technical innovations to implement the treatment in the ambulance and maybe obtain even more patency at an earlier stage. TRIAL REGISTRATION -: Trialregister NTR161

    Intravenous Targeted Microbubbles Carrying Urokinase versus Urokinase Alone in Acute Peripheral Arterial Thrombosis in a Porcine Model

    No full text
    Background Standard therapy in acute peripheral arterial occlusion consists of intra-arterial catheter-guided thrombolysis. As microbubbles may be used as a carrier for fibrinolytic agents and targeted to adhere to the thrombus, we can theoretically deliver the thrombolytic medication locally following simple intravenous injection. In this intervention-controlled feasibility study, we compared intravenously administered targeted microbubbles incorporating urokinase and locally applied ultrasound, with intravenous urokinase and ultrasound alone. Methods In 9 pigs, a thrombus was created in the left external iliac artery, after which animals were assigned to either receive targeted microbubbles and urokinase (UK + tMB group) or urokinase alone (UK group). In both groups, ultrasound was applied at the site of the occlusion. Blood flow through the iliac artery and microcirculation of the affected limb were monitored and the animals were euthanized 1 hr after treatment. Autopsy was performed to determine the weight of the thrombus and to check for adverse effects. Results In the UK + tMB group (n = 5), median improvement in arterial blood flow was 5 mL/min (range 0–216). Improvement was seen in 3 of these 5 pigs at conclusion of the experiment. In the UK group (n = 4), median improvement in arterial blood flow was 0 mL/min (−10 to 18), with slight improvement in 1 of 4 pigs. Thrombus weight was significantly lower in the UK + tMB group (median 0.9383 g, range 0.885–1.2809) versus 1.5399 g (1.337–1.7628; P = 0.017). No adverse effects were seen. Conclusions Based on this experiment, minimally invasive thrombolysis using intravenously administered targeted microbubbles carrying urokinase combined with local application of ultrasound is feasible and might accelerate thrombolysis compared with treatment with urokinase and ultrasound alone

    General anesthesia with sevoflurane decreases myocardial blood volume and hyperemic blood flow in healthy humans

    No full text
    BACKGROUND Preservation of myocardial perfusion during general anesthesia is likely important in patients at risk for perioperative cardiac complications. Data related to the influence of general anesthesia on the normal myocardial circulation are limited. In this study, we investigated myocardial microcirculatory responses to pharmacological vasodilation and sympathetic stimulation during general anesthesia with sevoflurane in healthy humans immediately before surgical stimulation. METHODS Six female and 7 male subjects (mean age 43 years, range 28-61) were studied at baseline while awake and during the administration of 1 minimum alveolar concentration sevoflurane. Using myocardial contrast echocardiography, myocardial blood flow (MBF) and microcirculatory variables were assessed at rest, during adenosine-induced hyperemia, and after cold pressor test-induced sympathetic stimulation. MBF was calculated from the relative myocardial blood volume multiplied by its exchange frequency (ÎČ) divided by myocardial tissue density (ρT), which was set at 1.05 g·mL(-1). RESULTS During sevoflurane anesthesia, MBF at rest was similar to baseline values (1.05 ± 0.28 vs 1.05 ± 0.32 mL·min(-1)·g(-1); P = 0.98; 95% confidence interval [CI], -0.18 to 0.18). Myocardial blood volume decreased (P = 0.0044; 95% CI, 0.01-0.04) while its exchange frequency (ÎČ) increased under sevoflurane anesthesia when compared with baseline. In contrast, hyperemic MBF was reduced during anesthesia compared with baseline (2.25 ± 0.5 vs 3.53 ± 0.7 mL·min(-1)·g(-1); P = 0.0003; 95% CI, 0.72-1.84). Sympathetic stimulation during sevoflurane anesthesia resulted in a similar MBF compared to baseline (1.53 ± 0.53 and 1.55 ± 0.49 mL·min(-1)·g(-1); P = 0.74; 95% CI, -0.47 to 0.35). CONCLUSIONS In otherwise healthy subjects who are not subjected to surgical stimulation, MBF at rest and after sympathetic stimulation is preserved during sevoflurane anesthesia despite a decrease in myocardial blood volume. However, sevoflurane anesthesia reduces hyperemic MBF, and thus MBF reserve, in these subjects

    Contrast-Enhanced Ultrasound for Myocardial Perfusion Imaging

    No full text
    Ultrasound contrast agents are gas-filled microbubbles that enhance visualization of cardiac structures, function and blood flow during contrast-enhanced ultrasound (CEUS). An interesting cardiovascular application of CEUS is myocardial contrast echocardiography, which allows real-time myocardial perfusion imaging. The intraoperative use of this technically challenging imaging method is limited at present, although several studies have examined its clinical utility during cardiac surgery in the past. In the present review we provide general information on the basic principles of CEUS and discuss the methodology and technical aspects of myocardial perfusion imaging
    corecore