    Fat suppression for ultrashort echo time imaging using a novel soft-hard composite radiofrequency pulse.

    Get PDF
    PurposeTo design a soft-hard composite pulse for fat suppression and water excitation in ultrashort echo time (UTE) imaging with minimal short T2 signal attenuation.MethodsThe composite pulse contains a narrow bandwidth soft pulse centered on the fat peak with a small negative flip angle (-α) and a short rectangular pulse with a small positive flip angle (α). The fat magnetization experiences both tipping-down and -back with an identical flip angle and thus returns to the equilibrium state, leaving only the excited water magnetization. Bloch simulations, as well as knee, tibia, and ankle UTE imaging studies, were performed to investigate the effectiveness of fat suppression and corresponding water signal attenuation. A conventional fat saturation (FatSat) module was used for comparison. Signal suppression ratio (SSR), defined as the ratio of signal difference between non-fat-suppression and fat-suppression images over the non-fat-suppression signal, was introduced to evaluate the efficiency of the composite pulse.ResultsNumerical simulations demonstrate that the soft-hard pulse has little saturation effect on short T2 water signals. Knee, tibia, and ankle UTE imaging results suggest that comparable fat suppression can be achieved with the soft-hard pulse and the FatSat module. However, much less water saturation is induced by the soft-hard pulse, especially for short T2 tissues, with SSRs reduced from 71.8 ± 6.9% to 5.8 ± 4.4% for meniscus, from 68.7 ± 5.5% to 7.7 ± 7.6% for bone, and from 62.9 ± 12.0% to 4.8 ± 3.2% for the Achilles tendon.ConclusionThe soft-hard composite pulse can suppress fat signals in UTE imaging with little signal attenuation on short T2 tissues

    MRI-based porosity index (PI) and suppression ratio (SR) in the tibial cortex show significant differences between normal, osteopenic, and osteoporotic female subjects

    Get PDF
    IntroductionUltrashort echo time (UTE) MRI enables quantitative assessment of cortical bone. The signal ratio in dual-echo UTE imaging, known as porosity index (PI), as well as the signal ratio between UTE and inversion recovery UTE (IR-UTE) imaging, known as the suppression ratio (SR), are two rapid UTE-based bone evaluation techniques developed to reduce the time demand and cost in future clinical studies. The goal of this study was to investigate the performance of PI and SR in detecting bone quality differences between subjects with osteoporosis (OPo), osteopenia (OPe), and normal bone (Normal).MethodsTibial midshaft of fourteen OPe (72 ± 6 years old), thirty-one OPo (72 ± 6 years old), and thirty-seven Normal (36 ± 19 years old) subjects were scanned using dual-echo UTE and IR-UTE sequences on a clinical 3T scanner. Measured PI, SR, and bone thickness were compared between OPo, OPe, and normal bone (Normal) subjects using the Kruskal–Wallis test by ranks. Spearman’s rank correlation coefficients were calculated between dual-energy x-ray absorptiometry (DEXA) T-score and UTE-MRI results.ResultsPI was significantly higher in the OPo group compared with the Normal (24.1%) and OPe (16.3%) groups. SR was significantly higher in the OPo group compared with the Normal (41.5%) and OPe (21.8%) groups. SR differences between the OPe and Normal groups were also statistically significant (16.2%). Cortical bone was significantly thinner in the OPo group compared with the Normal (22.0%) and OPe (13.0%) groups. DEXA T-scores in subjects were significantly correlated with PI (R=-0.32), SR (R=-0.50), and bone thickness (R=0.51).DiscussionPI and SR, as rapid UTE-MRI-based techniques, may be useful tools to detect and monitor bone quality changes, in addition to bone morphology, in individuals affected by osteoporosis

    Quantitative Ultrasound Techniques Used for Peripheral Nerve Assessment

    No full text
    Aim: This review article describes quantitative ultrasound (QUS) techniques and summarizes their strengths and limitations when applied to peripheral nerves. Methods: A systematic review was conducted on publications after 1990 in Google Scholar, Scopus, and PubMed databases. The search terms “peripheral nerve”, “quantitative ultrasound”, and “elastography ultrasound” were used to identify studies related to this investigation. Results: Based on this literature review, QUS investigations performed on peripheral nerves can be categorized into three main groups: (1) B-mode echogenicity measurements, which are affected by a variety of post-processing algorithms applied during image formation and in subsequent B-mode images; (2) ultrasound (US) elastography, which examines tissue stiffness or elasticity through modalities such as strain ultrasonography or shear wave elastography (SWE). With strain ultrasonography, induced tissue strain, caused by internal or external compression stimuli that distort the tissue, is measured by tracking detectable speckles in the B-mode images. In SWE, the propagation speed of shear waves, generated by externally applied mechanical vibrations or internal US “push pulse” stimuli, is measured to estimate tissue elasticity; (3) the characterization of raw backscattered ultrasound radiofrequency (RF) signals, which provide fundamental ultrasonic tissue parameters, such as the acoustic attenuation and backscattered coefficients, that reflect tissue composition and microstructural properties. Conclusions: QUS techniques allow the objective evaluation of peripheral nerves and reduce operator- or system-associated biases that can influence qualitative B-mode imaging. The application of QUS techniques to peripheral nerves, including their strengths and limitations, were described and discussed in this review to enhance clinical translation

    Robust Assessment of Macromolecular Fraction (MMF) in Muscle with Differing Fat Fraction Using Ultrashort Echo Time (UTE) Magnetization Transfer Modeling with Measured T1

    No full text
    Magnetic resonance imaging (MRI) is widely regarded as the most comprehensive imaging modality to assess skeletal muscle quality and quantity. Magnetization transfer (MT) imaging can be used to estimate the fraction of water and macromolecular proton pools, with the latter including the myofibrillar proteins and collagen, which are related to the muscle quality and its ability to generate force. MT modeling combined with ultrashort echo time (UTE-MT modeling) may improve the evaluation of the myotendinous junction and regions with fibrotic tissues in the skeletal muscles, which possess short T2 values and higher bound-water concentration. The fat present in muscle has always been a source of concern in macromolecular fraction (MMF) calculation. This study aimed to investigate the impact of fat fraction (FF) on the estimated MMF in bovine skeletal muscle phantoms embedded in pure fat. MMF was calculated for several regions of interest (ROIs) with differing FFs using UTE-MT modeling with and without T1 measurement and B1 correction. Calculated MMF using measured T1 showed a robust trend, particularly with a negligible error (<3%) for FF < 20%. Around 5% MMF reduction occurred for FF > 30%. However, MMF estimation using a constant T1 was robust only for regions with FF < 10%. The MTR and T1 values were also robust for only FF < 10%. This study highlights the potential of the UTE-MT modeling with accurate T1 measurement for robust muscle assessment while remaining insensitive to fat infiltration up to moderate levels