117 research outputs found

    Material incorporation inside single-walled carbon nanotubes using plasma-ion irradiation method

    Get PDF
    科研費報告書収録論文(課題番号:13852016/研究代表者:畠山力三/プラズマイオン照射による新機能性進化ナノチューブ創製法の開発

    Low-Power Complementary Inverter Based on Graphene/Carbon-Nanotube and Graphene/MoS<sub>2</sub> Barristors

    Get PDF
    The recent report of a p-type graphene(Gr)/carbon-nanotube(CNT) barristor facilitates the application of graphene barristors in the fabrication of complementary logic devices. Here, a complementary inverter is presented that combines a p-type Gr/CNT barristor with a n-type Gr/MoS2 barristor, and its characteristics are reported. A sub-nW (~0.2 nW) low-power inverter is demonstrated with a moderate gain of 2.5 at an equivalent oxide thickness (EOT) of ~15 nm. Compared to inverters based on field-effect transistors, the sub-nW power consumption was achieved at a much larger EOT, which was attributed to the excellent switching characteristics of Gr barristors

    An Evaluation of Relative Damage to the Powertrain System in Tracked Vehicles

    Get PDF
    The objective of this study was to improve the reliability of the endurance test for the powertrain system of military tracked vehicles. The measurement system that measures the driving duty applied to the powertrain system caused by mobility on roads consists of eight analog channels and two pulse channels, including the propeller shaft output torques for the left and right sides. The data obtained from this measurement system can be used to introduce a new technology that produces the output torque of a torque converter and that can be applied to analyze the revolution counting for the endurance and road mobility in the front unit and represent the relative fatigue damages analysis technique and its results according to the driven roads through a cumulative fatigue method

    Low temperature transfer and formation of carbon nanotube arrays by imprinted conductive adhesive

    Get PDF
    This letter demonstrates the transfer and formation of aligned carbon nanotube (CNT) arrays at low temperature by imprinted conductive adhesive. A thermoplastic isotropic conductive adhesive is patterned by an imprint and heat transfer process. The CNTs grown by thermal chemical vapor deposition are then transferred to another substrate by the conductive adhesive, forming predefined patterns. The current-voltage response of the transferred CNT bundles verifies that good electrical connection has been established. This process can enable the integration of CNTs into various temperature-sensitive processeses and materials

    Direct observation of DNA target searching and cleavage by CRISPR-Cas12a

    Get PDF
    Cas12a (also called Cpf1) is a representative type V-A CRISPR effector RNA-guided DNA endonuclease, which provides an alternative to type II CRISPR-Cas9 for genome editing. Previous studies have revealed that Cas12a has unique features distinct from Cas9, but the detailed mechanisms of target searching and DNA cleavage by Cas12a are still unclear. Here, we directly observe this entire process by using single-molecule fluorescence assays to study Cas12a from Acidaminococcus sp. (AsCas12a). We determine that AsCas12a ribonucleoproteins search for their on-target site by a one-dimensional diffusion along elongated DNA molecules and induce cleavage in the two DNA strands in a well-defined order, beginning with the non-target strand. Furthermore, the protospacer-adjacent motif (PAM) for AsCas12a makes only a limited contribution of DNA unwinding during R-loop formation and shows a negligible role in the process of DNA cleavage, in contrast to the Cas9 PAM.

    Hemodynamically balanced congenitally corrected transposition of the great arteries with a large ventricular septal defect, and subvalvular pulmonic stenosis: a case report

    Get PDF
    Background Adults with unoperated congenitally corrected transposition of the great arteries are rare but form a distinct group among adults with congenital heart disease. Patients with congenitally corrected transposition of the great arteries often have one or more associated cardiac anomalies that dictate the need for, and timing of, surgical intervention in childhood. However, in a proportion of patients, the hemodynamics does not require surgical attention during childhood, and, in some patients, a correct diagnosis is not established until adulthood. Here we report an adult case of unoperated congenitally corrected transposition of the great arteries with a large ventricular septal defect and probable pulmonary arterial hypertension. Case presentation Our patient was a 46-year-old Korean man. Transthoracic echocardiography and cardiac catheterization demonstrated hemodynamically balanced ventricles with a non-regurgitant systemic atrioventricular valve, normal pulmonary arterial pressure, and a reasonable difference between the oxygen saturation values of the aorta and pulmonary trunk, even with the presence of a large ventricular septal defect. Further morphological assessments using cardiac computed tomography and three-dimensional modeling/printing of his heart revealed that the mitral valve was straddling over the posteriorly positioned ventricular septal defect, which could explain the functional and anatomical subvalvular pulmonary stenosis and a small amount of shunt flow through the large ventricular septal defect. We interpreted this combination of cardiac defects as able to sustain his stable cardiac function. Thus, we decided to maintain his unoperated status. Conclusion A detailed anatomical understanding based on transthoracic echocardiography, cardiac computed tomography, and three-dimensional printing can justify a decision to not operate in cases of congenitally corrected transposition of the great arteries with hemodynamically balanced pulmonary stenosis and a ventricular septal defect, as observed in the present case

    Antimutagenic and anticarcinogenic effect of methanol extracts of Petasites japonicus Maxim leaves

    Get PDF
    The methanol extract from the leaves of Petasites japonicus Maxim (PJ) was studied for its (anti-)mutagenic effect with the SOS chromotest and reverse mutation assay. The (anti-)carcinogenic effects were evaluated by the cytotoxicity on human cancer line cells and by the function and the expression of gap junctions in rat liver epithelial cell. PJ extracts significantly decreased spontaneous β-galactosidase activity and β-galactosidase activity induced by a mutagen, ICR, in Salmonella (S.) typhimurium TA 1535/pSK 1002. All doses of the extract (0.08-100 mg/plate) decreased the reversion frequency induced by benzo (α)pyrene (BaP) in S. typhimurium TA 98. It decreased not only the spontaneous reversion frequency but also that induced by BaP in S. typhimurium TA 100. PJ extract showed greater cytotoxic effects on human stomach, colon and uterus cancer cells than on other cancer cell types and normal rat liver epithelial cells. Dye transfers though gap junctions were significantly increased by PJ extracts at concentrations greater than 200 µg/mL and the inhibition of dye transfer by 12-O-tetradecanoylphorobol-13-acetate (TPA) was obstructed in all concentrations of PJ. PJ significantly increased the numbers of gap junction protein connexin 43, and increased the protein expression decreased by TPA in a dose-dependent manner. Based on these findings, PJ is suggested to contain antimutagenic and anticarcionogenic compounds

    Dose-Volume Analysis of Lung and Heart according to Respiration in Breast Cancer Patients Treated with Breast Conserving Surgery

    Get PDF
    Purpose: Adjuvant radiotherapy of breast cancer using a photon tangential field incurs a risk of late heart and lung toxicity. The use of free breathing (FB), expiration breath hold (EBH), and deep inspiration breath hold (DIBH) during tangential breast radiotherapy as a means of reducing irradiated lung and heart volume was evaluated. Methods: In 10 women with left-sided breast cancer (mean age, 44 years) post-operative computed tomography (CT) scanning was done under different respiratory conditions using FB, EBH, and DIBH in 3 CT scans. For each scan, an optimized radiotherapy plan was designed with 6 MV photon tangential fields encompassing the clinical target volume after breast-conserving surgery. Results: The results of dose-volume histograms were compared using three breathing pattern techniques for the irradiated volume and dose to the heart. A significant reduction dose to the irradiated heart volume for the DIBH breathing technique was compared to FB and EBH breathing techniques (p&amp;lt;0.05). Conclusion: This study demonstrated that the irradiated heart volume can be significantly reduced in patients with left-sided breast cancer using the DIBH breathing technique for tangential radiotherapy

    Controlled Synthesis of Monolayer Graphene Toward Transparent Flexible Conductive Film Application

    Get PDF
    We demonstrate the synthesis of monolayer graphene using thermal chemical vapor deposition and successive transfer onto arbitrary substrates toward transparent flexible conductive film application. We used electron-beam-deposited Ni thin film as a synthetic catalyst and introduced a gas mixture consisting of methane and hydrogen. To optimize the synthesis condition, we investigated the effects of synthetic temperature and cooling rate in the ranges of 850–1,000°C and 2–8°C/min, respectively. It was found that a cooling rate of 4°C/min after 1,000°C synthesis is the most effective condition for monolayer graphene production. We also successfully transferred as-synthesized graphene films to arbitrary substrates such as silicon-dioxide-coated wafers, glass, and polyethylene terephthalate sheets to develop transparent, flexible, and conductive film application
    corecore