1 research outputs found

    Chromium Speciation in Wastewater and Sewage by Solid-Phase Extraction Using a New Diphenylcarbazone-Incorporated Resin

    Get PDF
    A new procedure for the determination of chromium species in polluted environmental samples by flame atomic absorption spectrometry was developed in this work. A new material containing 1,5-diphenylcarbazone included in a polymeric matrix was prepared and employed as a solid-phase extraction material for selective separation of Cr(III) ions under dynamic conditions. Chromium(III) ions were retained on this sorbent with high efficiency and repeatability (95 %, RSD = 1 %) from solutions with pH 9.0. The quantitative recovery of analyte was obtained with 0.1 mol L−1 EDTA. The concentration of Cr(VI) ions was calculated from the difference between the concentration of total chromium and Cr(III) ions. The prepared sorbent exhibits good chemical and mechanical stability, sorption capacity and selectivity towards Cr(III) ions in the presence of Cu(II), Ni(II), Mn(II) and Ca(II) ions. The accuracy of the separation method was proved by analysis of reference material of wastewater RES 10.2. The developed procedure was applied for chromium speciation analysis in municipal sewage samples.Barbara Leśniewska: [email protected] Leśniewska - Institute of Chemistry, University of BialystokAnna Jeglikowska - Institute of Chemistry, University of BialystokBeata Godlewska-Żyłkiewicz - Institute of Chemistry, University of BialystokAboufazeli, F., Lotfi, Z. Z., Hamid, R., Sadeghi, O., Karimi, M., & Najafi, E. (2013). Novel ion imprinted polymer magnetic mesoporous silica nano-particles for selective separation and determination of lead ions in food samples. Food Chemistry, 141, 3459–3465.Bagheri, A., Behbahani, M., Amini, M. M., Sadeghi, O., Taghizade, M., Baghayi, L., & Salarian, M. (2012). Simultaneous separation and determination of trace amounts of Cd(II) and Cu(II) in environmental samples using novel diphenylcarbazide modified nanoporous silica. Talanta, 89, 455–461.Barałkiewicz, D., Pikosz,B.,Belter,M.,&Marcinkowska,M. (2013). Speciation analysis of chromium in drinking water samples by ion-pair reversed-phase HPLC-ICP-MS: validation of the analytical method and evaluation of the uncertainty budget. Accreditation and Quality Assurance, 18, 391–401.Bayramoglu, G., & Arica, M. Y. (2011). Synthesis of Cr(VI)-imprinted poly(4-vinyl pyridine-co-hydroxyethyl methacrylate) particles: its adsorption propensity to Cr(VI). Journal of Hazardous Materials, 187, 213–221.Behbahani, M., Bagheri, A., Amini, M. M., Sadeghi, O., Salarian, M., Najafi, F., & Taghizadeh, M. (2013a). Application of multiwalled carbon nanotubes modified by diphenylcarbazide for selective solid phase extraction of ultra traces Cd(II) in water samples and food products. Food Chemistry, 141, 48–53.Behbahani, M., Bagheri, A., Taghizadeh, M., Salarian, M., Sadeghi, O., Adlnasab, L., & Jalali, K. (2013b). Synthesis and characterisation of nano structure lead (II) ion-imprinted polymer as a new sorbent for selective extraction and preconcentration of ultra trace amounts of lead ions from vegetables, rice, and fish samples. Food Chemistry, 138, 2050–2056.Report on Carcinogens, Thirteenth Edition. (2014). Chromium hexavalent compounds, CAS No. 18540-29-9, National Toxicology Program, Department of Health and Human Services. (http://ntp.niehs.nih.gov/go/roc13).Chang, Q., Song, S., Wang, Y., Li, J., & Ma, J. (2012). Application of grapheme as a sorbent for preconcentration and determination of trace amounts of chromium(III) in water samples by flame atomic absorption spectrometry. Analytical Methods, 4, 1110–1016.EEATechnical report. (2015). European Union emission inventory report 1990–2013 under the UNECE Convention on Longrange Transboundary Air Pollution (LRTAP) (Vol. 8, p. 69). Luxembourg: Publications Office of the European Union. http://www.eea.europa.eu/publications/lrtap-emissioninventory-report/#parent-fieldname-title; 18.12.2015.EPA (2014). Priority pollutant list: http://www2.epa.gov/eg/toxicand-priority-pollutants-under-clean-water-act (6.12.2015).Filik, H., Doğutan, M., & Apak, R. (2003). Speciation analysis of chromium by separation on a 5-palmitoyl oxine-functionalized XAD-2 resin and spectrophotometric determination with diphenylcarbazide. Analytical and Bioanalytical Chemistry, 376, 928–933.Hoet, P. (2005). Speciation of chromium in occupational exposure and clinical aspects. In R. Cornelis, H. Crews, J. Caruso, & K. G. Heumann (Eds.), Handbook of elemental speciation II: species in the environment, food, medicine & occupational health (pp. 135–157). Chichester: Wiley, Ltd.IARC. (1990). Monographs on the evaluation of carcinogenic risks to humans. Chromium, nickel and welding (Vol. 49, pp. 49–214). Lyon: WHO International Agency for Research on Cancer.Inczedy, J, Lengyel, T, Ure, AM, Gelencser, A, Hulanicki, A (1998) Compendium of analytical nomenclature. 3rd ed. IUPAC, Blackwell Science.Kotaś, J., & Stasicka, Z. (2000). Chromium occurrence in the environment and methods of its speciation. Environmental Pollution, 107, 263–283.Leśniewska, B., Kosińska, M., Godlewska-Żyłkiewicz, B., Zambrzycka, E., & Wilczewska, A. Z. (2011). Studies of new sorbents based on imprinted complexes of Pt(II) with thiosemicarbazone derivatives for separation and determination of platinum in environmental samples by electrothermal atomic absorption spectrometry. Mikrochimica Acta, 175, 273–282.Leśniewska, B., Godlewska-Żyłkiewicz, B., & Wilczewska, A. Z. (2012). Separation and preconcentration of trace amounts of Cr(III) ions on ion imprinted polymer from water samples. Microchemical Journal, 105, 88–93.Leśniewska, B., Trzonkowska, L., Zambrzycka, E., & GodlewskaŻyłkiewicz, B. (2015). Multi-commutation flow system with on-line solid phase extraction exploiting the ion-imprinted polymer and FAAS detection for chromium speciation analysis in sewage samples. Analytical Methods, 7, 1517–1526.Long, X., Miro, M., & Hansen, H. (2005). Universal approach for selective trace metal determinations via sequential injection-bead injection-lab on valve using renewable hydrophobic bead surfaces as reagent carriers. Analytical Chemistry, 77, 6032–6041.Ma, J., Yuan, D., & Byrne, R. H. (2014). Flow injection analysis of trace chromium(VI) in drinking water with a liquid waveguide capillary cell and spectrophotometric detection. Environmental Monitoring and Assessment, 186, 367–373.Madzgalj, A., Baesso, M. L., & Franko, M. (2008). Flow injection thermal lens spectrometric detection of hexavalent chromium. European Physical Journal Special Topics, 153, 503–506.Metze, D., Jakubowski, N., & Klockow, D. (2005). Speciation of chromium in environment and food. In R. Cornelis, H. Crews, J. Caruso, & K. G. Heumann (Eds.), Handbook of elemental speciation II: species in the environment, food, medicine & occupational health (pp. 120–134). Chichester: Wiley, Ltd.Moghimi, A., & Poursharifi, M. J. (2011). Preconcentration and determination of mercury(II) using modified silica gel with diphenylthiocarbazone by cold vapour atomic absorption spectrometry. Asian Journal of Chemistry, 23, 4117.Mondal, B. C., Das, D., & Das, A. K. (2002). Synthesis and characterization of a new resin functionalized with 2-naphthol-3,6-disulfonic acid and its application for the speciation of chromium in natural water. Talanta, 56, 145–152.Mulaudzi, L. V., Staden, J. F., & Stefan, R. I. (2002). Determination of chromium(III) and chromium(VI) by use of a spectrophotometric sequential injection system. Analytica Chimica Acta, 467, 51–60.Namieśnik, J., & Rabajczyk, A. (2012). Speciation analysis of chromium in environmental samples. Critical Reviews in Environmental Science and Technology, 42, 327–377.Narin, I., Soylak, M., Kayakirilmaz, K., Elci, L., & Dogan, M. (2002). Speciation of Cr(III) and Cr(VI) in tannery wastewater and sediment samples on Ambersorb 563 resin. Analytical Letters, 35, 1437–1452.Narin, I., Surme, Y., Soylak, M., & Dogand, M. (2006). Speciation of Cr(III) and Cr(VI) in environmental samples by solid phase extraction on Ambersorb 563 resin. Journal of Hazardous Materials, B136, 579–584.Narin, I., Kars, A., & Soylak, M. (2008). A novel solid phase extraction procedure on Amberlite XAD-1180 for speciation of Cr(III), Cr(VI) and total chromium in environmental and pharmaceutical samples. Journal of Hazardous Materials, 150, 453–458.Ordinance of the Minister of Environment concerning the conditions for spreading sewage into the water or soil, and on substances particularly harmful to the aquatic environment. Official Journal (2014),1800, p. 1–42 (in Polish).Pena, F., Lavilla, I., & Bendicho, C. (2008). Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal atomic absorption spectrometry. Spectrochimica Acta B, 63, 498–503.Pettine, M., & Capri, S. (2005). Removal of humic matter interference in the determination of Cr(VI) in soil extracts by the diphenylcarbazide method. Analytica Chimica Acta, 540, 239–246.Pyrzyńska, K. (2012). Non-chromatographic speciation analysis of chromium in natural waters. International Journal of Environmental Analytical Chemistry, 92, 1262–1275.Rajesh, N., Jalan, R. K., & Howany, P. (2008). Solid phase extraction of chromium (VI) from aqueous solutions by adsorption of its diphenylocarbazide complex on an Amberlite XAD-4 resin column. Journal of Hazardous Materials, 150, 723–727.Ščančar, J., & Milačič, R. (2014). A critical overview of Cr speciation analysis based on high performance liquid chromatography and spectrometric techniques. Journal of Analytical Atomic Spectrometry, 29, 427–443.Soylak, M., & Kizil, N. (2013). Neodymium(III) hydroxide coprecipitation-FAAS system for the speciation of chromium in natural waters. Atom Spectrosc, 34, 216–220.Stanisławska, M., Janasik, B., & Wasowicz, W. (2013). Application of high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICPMS) for determination of chromium compounds in the air at the workplace. Talanta, 117, 14–19.Themelis, D. G., Kika, F. S., & Economou, A. (2006). Flow injection direct spectrophotometric assay for the speciation of trace chromium(III) and chromium(VI) using chromotropic acid as chromogenic reagent. Talanta, 69, 615–620.Tunceli, A., & Turker, A. (2002). Speciation of Cr(III) and Cr(VI) in water after preconcentration of its 1,5-diphenylcarbazone complex on amberlite XAD-16 resin and determination by FAAS. Talanta, 57, 1199–1204.Tuzen, M., & Soylak, M. (2006). Chromium speciation in environmental samples by solid phase extraction on Chromosorb 108. Journal of Hazardous Materials, 129, 266–273.Tuzen, M., Uluozlu, O. D., & Soylak, M. (2007). Cr(VI) and Cr(III) speciation on Bacillus sphaericus loaded diaion SP850 resin. Journal of Hazardous Materials, 144, 549–555.Unsal, Y. E., Tuzen, M., & Soylak, M. (2014). Speciation of chromium by the combination of dispersive liquid-liquid microextraction and microsample injection flame atomic absorption spectrometry. Turkish Journal of Chemistry, 38, 173–181.Uygun, M., Feyzioğlu, E., Özçalışkan, E., Caka, M., Ergen, A., Akgöl, A., & Denizli, A. (2013). New generation ionimprinted nanocarrier for removal of Cr(VI) from wastewater. Journal of Nanoparticle Research, 15, 1–11.Yuan, D., Fu, D., Wang, R., & Yuan, J. (2008). Rapid determination of chromium(VI) in electroplating waste water by use of a spectrophotometric flow injection system. Spectrochimica Acta B, 71, 276–279.Zhai, Y., Duan, S., He, Q., Yang, X., & Han, Q. (2010). Solid phase extraction and preconcentration of trace mercury(II) from aqueous solution using magnetic nanoparticles doped with 1,5-diphenylcarbazide. Mikrochimica Acta, 169, 353–360.Zhang, N., Suleiman, J. S., He, M., & Hu, B. (2008). Chromium(III)-imprinted silica gel for speciation analysis of chromium in environmental water samples with ICP-MS detection. Talanta, 75, 536–543.Zhao, X., Song, N., Zhou, W., & Jia, Q. (2012). Preconcentration procedures for determination of chromium using atomic spectrometric techniques. Central European Journal of Chemistry, 10, 927–937
    corecore