275 research outputs found
Recommended from our members
Current Knowledge and Attitudes Concerning Cost-Effectiveness in Glaucoma Pharmacotherapy: A Glaucoma Specialists Focus Group Study.
Background:Rising healthcare costs motivate continued cost-reduction efforts. To help lower costs associated with open-angle glaucoma (OAG), a prevalent, progressive disease with substantial direct and indirect costs, clinicians need to understand the cost-effectiveness of intraocular pressure (IOP)-lowering pharmacotherapies. There is little published information on clinicians' knowledge and attitudes about cost-effectiveness in glaucoma treatment. Purpose:This pilot focus group study aimed to explore clinician attitudes and perspectives around the costs and cost drivers of glaucoma therapy; the implementation of cost-effectiveness decisions; the clinical utility of cost-effectiveness studies; and the cost-effectiveness of available treatments. Methods:Six US glaucoma specialists participated in two separate teleconferencing sessions (three participants each), managed by an independent, skilled moderator (also a glaucoma specialist) using a discussion guide. Participants reviewed recent publications (n=25) on health economics outcomes research in glaucoma prior to the sessions. Results:Participants demonstrated a clear understanding of the economic burden of glaucoma therapy and identified medications, diagnostics, office visits, and treatment changes as key cost drivers. They considered cost-effectiveness an appropriate component of treatment decision-making but identified the need for additional data to inform these decisions. Participants indicated that there were only a few recent studies on health economics outcomes in glaucoma which evaluate parameters important to patient care, such as quality of life and medication adherence, and that longitudinal data were scant. In addition to efficacy, participants felt patient adherence and side-effect profile should be included in economic evaluations of glaucoma pharmacotherapy. Recently approved medications were evaluated in this context. Conclusion:Clinicians deem treatment decisions based on cost-effectiveness data as clinically appropriate. Newer IOP-lowering therapies with potentially greater efficacy and favorable side-effect and adherence profiles may help optimize cost-effectiveness. Future studies should include: clinicians' perspectives; lack of commercial bias; analysis of long-term outcomes/costs; more comprehensive parameters; real-world (including quality-of-life) data; and a robust Markov model
Structural Change Can Be Detected in Advanced-Glaucoma Eyes.
PurposeTo compare spectral-domain optical coherence tomography (SD-OCT) standard structural measures and a new three-dimensional (3D) volume optic nerve head (ONH) change detection method for detecting change over time in severely advanced-glaucoma (open-angle glaucoma [OAG]) patients.MethodsThirty-five eyes of 35 patients with very advanced glaucoma (defined as a visual field mean deviation < -21 dB) and 46 eyes of 30 healthy subjects to estimate aging changes were included. Circumpapillary retinal fiber layer thickness (cpRNFL), minimum rim width (MRW), and macular retinal ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured using the San Diego Automated Layer Segmentation Algorithm (SALSA). Progression was defined as structural loss faster than 95th percentile of healthy eyes. Three-dimensional volume ONH change was estimated using the Bayesian-kernel detection scheme (BKDS), which does not require extensive retinal layer segmentation.ResultsThe number of progressing glaucoma eyes identified was highest for 3D volume BKDS (13, 37%), followed by GCPIL (11, 31%), cpRNFL (4, 11%), and MRW (2, 6%). In advanced-OAG eyes, only the mean rate of GCIPL change reached statistical significance, -0.18 μm/y (P = 0.02); the mean rates of cpRNFL and MRW change were not statistically different from zero. In healthy eyes, the mean rates of cpRNFL, MRW, and GCIPL change were significantly different from zero. (all P < 0.001).ConclusionsGanglion cell-inner plexiform layer and 3D volume BKDS show promise for identifying change in severely advanced glaucoma. These results suggest that structural change can be detected in very advanced disease. Longer follow-up is needed to determine whether changes identified are false positives or true progression
Recommended from our members
Macular Pigment and Visual Function in Patients With Glaucoma: The San Diego Macular Pigment Study.
PurposeAlthough recent studies have shown that macular pigment (MP) is significantly lower in glaucoma patients, this relationship merits further investigation.MethodsThis cross-sectional study included 85 glaucoma patients and 22 controls. All subjects had standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) thickness measurements. Intake of lutein (L) and zeaxanthin (Z) was estimated using a novel dietary screener. The Heidelberg Spectralis dual-wavelength autofluorescence (AF) technology was employed to study the relationship between MP and glaucoma. The association between MP volume and glaucoma was investigated using linear regression models accounting for potential confounding factors.ResultsGlaucoma patients had significantly worse SAP mean deviation (MD) and lower RNFL thickness in the study eye compared to control subjects (P < 0.001 for both). MP (volume) was comparable between groups (P = 0.436). In the univariable model, diagnosis of glaucoma was not associated with MP volume (R2 = 1.22%; P = 0.257). Dietary intake of L and Z was positively and significantly related to MP in the univariable (P = 0.022) and multivariable (P = 0.020) models.ConclusionsThese results challenge previous studies that reported that glaucoma is associated with low MP. Dietary habits were found to be the main predictor of MP in this sample. Further research is merited to better understand the relationship between glaucoma, MP, and visual performance in these patients
Recommended from our members
Association of severity of primary open-angle glaucoma with serum vitamin D levels in patients of African descent.
PurposeTo study the relationship between primary open-angle glaucoma (POAG) in a cohort of patients of African descent (AD) and serum vitamin D levels.MethodsA subset of the AD and glaucoma evaluation study III (ADAGES III) cohort, consisting of 357 patients with a diagnosis of POAG and 178 normal controls of self-reported AD, were included in this analysis. Demographic information, family history, and blood samples were collected from all the participants. All the subjects underwent clinical evaluation, including visual field (VF) mean deviation (MD), central cornea thickness (CCT), intraocular pressure (IOP), and height and weight measurements. POAG patients were classified into early and advanced phenotypes based on the severity of their visual field damage, and they were matched for age, gender, and history of hypertension and diabetes. Serum 25-Hydroxy (25-OH) vitamin D levels were measured by enzyme-linked immunosorbent assay (ELISA). The association of serum vitamin D levels with the development and severity of POAG was tested by analysis of variance (ANOVA) and the paired t-test.ResultsThe 178 early POAG subjects had a visual field MD of better than -4.0 dB, and the 179 advanced glaucoma subjects had a visual field MD of worse than -10 dB. The mean (95% confidence interval [CI]) levels of vitamin D of the subjects in the control (8.02 ± 6.19 pg/ml) and early phenotype (7.56 ± 5.74 pg/ml) groups were significantly or marginally significantly different from the levels observed in subjects with the advanced phenotype (6.35 ± 4.76 pg/ml; p = 0.0117 and 0.0543, respectively). In contrast, the mean serum vitamin D level in controls was not significantly different from that of the subjects with the early glaucoma phenotype (p = 0.8508).ConclusionsIn this AD cohort, patients with advanced glaucoma had lower serum levels of vitamin D compared with early glaucoma and normal subjects
MRI safety and devices: An update and expert consensus
Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/154533/1/jmri26909_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/154533/2/jmri26909.pd
Millimeter-wave array receivers for remote sensing
Recent developments in millimeter-wave receiver have enabled new remote sensing capabilities. MMIC circuits operating at frequencies as high as 200 GHz have enabled low-cost mass producible integrated receivers suitable for array applications. We will describe several ground-based demonstrations of this technology including development of integrated spectral line receivers for atmospheric remote sensing, a synthetic thinned aperture radiometer for atmospheric sounding and imaging and polarimetric array radiometers for astrophysics applications
Recommended from our members
Long-term variability of retinal nerve fibre layer thickness measurement in patients with glaucoma of African and European descents
BackgroundTo examine long-term retinal nerve fibre layer thickness (RNFLT) variability and associated clinical factors in African (AD) and European descent (ED) individuals with glaucoma.MethodsThis retrospective cohort study included glaucoma eyes of AD and ED from Diagnostic Innovations in Glaucoma Study/The African Descent and Glaucoma Evaluation Study with ≥4 visits/2 years of follow-up. We calculated optic nerve head RNFLT variability per-examination/visit as the absolute error of its residuals across follow-up. Full, baseline and parsimonious linear-mixed models were fit to evaluate the effects of clinical factors (demographics and ocular characteristics, prior/intervening glaucoma surgeries and cataract extraction (CE), RNFLT thinning rate, scan quality, visit/testing frequency, etc) on RNFLT variability in both races.ResultsThere were 376 and 625 eyes (226 and 349 participants) of AD and ED, and the mean (95% CI) RNFLT variability was 1.62 (1.52, 1.71) µm and 1.42 (1.34, 1.50) µm, respectively (p=0.002). AD and ED had some shared predictors of RNFLT variability, including intraocular pressure fluctuation and scan quality, although the effects varied (p<0.05). In both races, intervening CE was most strongly correlated with higher RNFLT variability (β: 0.24-0.92, p<0.05). After excluding eyes with intervening CE, RNFLT variability was reduced and the small racial difference was no longer significant (AD: 1.40 (1.31, 1.48) µm vs ED: 1.34 (1.27, 1.40) µm; p=0.280).ConclusionsAlthough some predictors were identified, long-term RNFLT variability appeared small for both AD and ED eyes. Moreover, the racial difference did not remain once intervening CE, the strongest predictor of variability, was eliminated. Our findings inform on strategies to optimise structural assessment and suggest that, when accounting for relevant factors, RNFLT is reliable across races
Millimeter-wave array receivers for remote sensing
Recent developments in millimeter-wave receiver have enabled new remote sensing capabilities. MMIC circuits operating at frequencies as high as 200 GHz have enabled low-cost mass producible integrated receivers suitable for array applications. We will describe several ground-based demonstrations of this technology including development of integrated spectral line receivers for atmospheric remote sensing, a synthetic thinned aperture radiometer for atmospheric sounding and imaging and polarimetric array radiometers for astrophysics applications
Millimeter-wave array receivers for remote sensing
Recent developments in millimeter-wave receiver have enabled new remote sensing capabilities. MMIC circuits operating at frequencies as high as 200 GHz have enabled low-cost mass producible integrated receivers suitable for array applications. We will describe several ground-based demonstrations of this technology including development of integrated spectral line receivers for atmospheric remote sensing, a synthetic thinned aperture radiometer for atmospheric sounding and imaging and polarimetric array radiometers for astrophysics applications
- …