7 research outputs found

    A Phase IV Study of Thromboembolic and Bleeding Events Following Hip and Knee Arthroplasty Using Oral Factor Xa Inhibitor

    Get PDF
    AbstractBackgroundMultiple randomized controlled trials have documented the effectiveness of rivaroxaban in the prevention of venous thromboembolism up to 1-month following total joint arthroplasty. However, the effectiveness and safety of rivaroxaban in the real-world setting, outside of the strict protocols used by randomized clinical trials, are unknown.MethodsThis was a prospective, observational, noninterventional, phase IV study of 3914 consecutive patients who underwent total joint arthroplasty from June 2010 to December 2012. Patients were treated with rivaroxaban 10 mg by mouth daily starting postoperative day 1 and continued for 15 days. Participants were followed up in clinic at 6 weeks and contacted by telephone at 12 weeks. The primary outcome of interest was symptomatic venous thromboembolism; secondary outcomes included bleeding events, transfusion requirements, and death.ResultsThe incidence of symptomatic deep venous thrombosis at 3 months was 0.5% (n = 18). Only 1 deep venous thrombosis event occurred within 7 days of surgery. The incidence of symptomatic pulmonary embolism (PE) at 3 months was 0.7% (n = 28). Thirteen PEs (46%) occurred within 7 days of surgery. The rate of major bleeding while on prophylaxis was 0.1%. Only 5% of patients received a blood transfusion. No deaths were attributed to thromboembolic events.ConclusionThis prospective, observational, phase IV study demonstrates that rivaroxaban appears to protect patients against symptomatic PE and is not associated with major bleeding events when used in a real-world setting as described

    Assessing stability and change of four performance measures: a longitudinal study evaluating outcome following total hip and knee arthroplasty

    Get PDF
    BACKGROUND: Physical performance measures play an important role in the measurement of outcome in patients undergoing hip and knee arthroplasty. However, many of the commonly used measures lack information on their psychometric properties in this population. The purposes of this study were to examine the reliability and sensitivity to change of the six minute walk test (6MWT), timed up and go test (TUG), stair measure (ST), and a fast self-paced walk test (SPWT) in patients with hip or knee osteoarthritis (OA) who subsequently underwent total joint arthroplasty. METHODS: A sample of convenience of 150 eligible patients, part of an ongoing, larger observational study, was selected. This included 69 subjects who had a diagnosis of hip OA and 81 diagnosed with knee OA with an overall mean age of 63.7 ± 10.7 years. Test-retest reliability, using Shrout and Fleiss Type 2,1 intraclass correlations (ICCs), was assessed preoperatively in a sub-sample of 21 patients at 3 time points during the waiting period prior to surgery. Error associated with the measures' scores and the minimal detectable change at the 90% confidence level was determined. A construct validation process was applied to evaluate the measures' abilities to detect deterioration and improvement at two different time points post-operatively. The standardized response mean (SRM) was used to quantify change for all measures for the two change intervals. Bootstrapping was used to estimate the 95% confidence intervals (CI) for the SRMs. RESULTS: The ICCs (95% CI) were as follows: 6MWT 0.94 (0.88,0.98), TUG 0.75 (0.51, 0.89), ST 0.90 (0.79, 0.96), and the SPWT 0.91 (0.81, 0.97). Standardized response means varied from .79 to 1.98, being greatest for the ST and 6MWT over the studied time intervals. CONCLUSIONS: The test-retest estimates of the 6MWT, ST, and the SPWT met the requisite standards for making decisions at the individual patient level. All measures were responsive to detecting deterioration and improvement in the early postoperative period

    Modeling early recovery of physical function following hip and knee arthroplasty

    Get PDF
    BACKGROUND: Information on early recovery after arthroplasty is needed to help benchmark progress and make appropriate decisions concerning patient rehabilitation needs. The purpose of this study was to model early recovery of physical function in patients undergoing total hip (THA) and knee (TKA) arthroplasty, using physical performance and self-report measures. METHODS: A sample of convenience of 152 subjects completed testing, of which 69 (mean age: 66.77 ± 8.23 years) underwent THA and 83 (mean age: 60.25 ± 11.19 years) TKA. Postoperatively, patients were treated using standardized care pathways and rehabilitation protocols. Using a repeated measures design, patients were assessed at multiple time points over the first four postoperative months. Outcome measures included the Lower Extremity Function Scale (LEFS), the physical function subscale of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC PF), the 6 minute walk test (6 MWT), timed up and go test (TUG) and a timed stair test (ST). Average recovery curves for each of the measures were characterized using hierarchical linear modeling. Predictors of recovery were sequentially modeled after validation of the basic developmental models. RESULTS: Slopes of recovery were greater in the first 6 to 9 weeks with a second-degree polynomial growth term (weeks squared) providing a reasonable fit for the data over the study interval. Different patterns of recovery were observed between the self-report measures of physical function and the performance measures. In contrast to the models for the WOMAC PF and the LEFS, site of arthroplasty was a significant predictor (p = 0.001) in all of the physical performance measure models with the patients post TKA initially demonstrating higher function. Site of arthroplasty (p = 0.025) also predicted the rate of change for patients post THA and between 9 to 11 weeks after surgery, the THA group surpassed the function of the patients post TKA. CONCLUSION: Knowledge about the predicted growth curves will assist clinicians in referencing patient progress, and determining the critical time points for measuring change. The study has contributed further evidence to highlight the benefit of using physical performance measures to learn about the patients' actual level of disability

    Assessing stability and change of four performance measures: a longitudinal study evaluating outcome following total hip and knee arthroplasty

    No full text
    Abstract Background Physical performance measures play an important role in the measurement of outcome in patients undergoing hip and knee arthroplasty. However, many of the commonly used measures lack information on their psychometric properties in this population. The purposes of this study were to examine the reliability and sensitivity to change of the six minute walk test (6MWT), timed up and go test (TUG), stair measure (ST), and a fast self-paced walk test (SPWT) in patients with hip or knee osteoarthritis (OA) who subsequently underwent total joint arthroplasty. Methods A sample of convenience of 150 eligible patients, part of an ongoing, larger observational study, was selected. This included 69 subjects who had a diagnosis of hip OA and 81 diagnosed with knee OA with an overall mean age of 63.7 ± 10.7 years. Test-retest reliability, using Shrout and Fleiss Type 2,1 intraclass correlations (ICCs), was assessed preoperatively in a sub-sample of 21 patients at 3 time points during the waiting period prior to surgery. Error associated with the measures' scores and the minimal detectable change at the 90% confidence level was determined. A construct validation process was applied to evaluate the measures' abilities to detect deterioration and improvement at two different time points post-operatively. The standardized response mean (SRM) was used to quantify change for all measures for the two change intervals. Bootstrapping was used to estimate the 95% confidence intervals (CI) for the SRMs. Results The ICCs (95% CI) were as follows: 6MWT 0.94 (0.88,0.98), TUG 0.75 (0.51, 0.89), ST 0.90 (0.79, 0.96), and the SPWT 0.91 (0.81, 0.97). Standardized response means varied from .79 to 1.98, being greatest for the ST and 6MWT over the studied time intervals. Conclusions The test-retest estimates of the 6MWT, ST, and the SPWT met the requisite standards for making decisions at the individual patient level. All measures were responsive to detecting deterioration and improvement in the early postoperative period
    corecore