7 research outputs found

    Number of γ-H2AX positive cells per unit area.

    No full text
    <p>The measurements were performed in the granular layer of the cerebellum. A) Shows the number of cells in normal rats while B) shows the number of cells in tumour-bearing animals. Stars show significant differences between 4 and 8 hours. Error bars correspond to SD.</p

    Different width of the radiation paths.

    No full text
    <p>A) Microbeam tracks as outlined by γ-H2AX stain at 4 and 8 hours after a 350 Gy irradiation. The high dose delivered resulted in an increase in the width of the microbeam track over time. B) Intensity of the fluorescence of the areas depicted in A.</p

    γ-H2AX stain comparison between micro- and broad beam configurations.

    No full text
    <p>Horizontal sections of the irradiated right cerebral hemisphere and the cerebellum of Wistar rats. Images A—D were obtained from the irradiated right cerebral hemisphere and cerebellum of animals exposed to 350 Gy of either microbeam or broad beam; dissected 8 hours after irradiation. For the MRT array, the center-to-center distance was 200 μm. The position and intensity of the γ-H2AX marker (green) correlate with the deposition of the peak synchrotron doses. A) Radiation tracks of the microbeams in the right cerebral hemisphere. B) Right cerebral hemisphere after broad beam irradiation C) Radiation tracks of the microbeams in the cerebellum. D) Cerebellum after broad beam irradiation. E) Horizontal section through the whole cerebellum after exposure of the right hemisphere to microbeams of 350 Gy; dissected at 4 hours after irradiation.</p

    Mean thickness of the radiation tracks in the cerebellum.

    No full text
    <p>Microbeam irradiation was given to both normal (A) and tumour-bearing rats (B). The width of the microbeams was 25 μm, which is represented by the dotted line. Animals were exposed to 35, 70, or 350 Gy to their right cerebral hemisphere. Four and 8 hours indicate the two dissection times after irradiation. Different letters and different letter cases indicate significant differences between groups and within each group respectively. Error bars show SD.</p

    Comparison of radiation tracks produced by the same intended microbeam configuration (center-to-center distance of 200 μm).

    No full text
    <p>By design the collimator spatially fractionates the microbeams with a center-to-center distance of 400 μm; to generate a center-to-center distance of 200 μm the collimator moves laterally followed by a second passage of the animal through the beam. A) Variable center-to-center distance of the microbeams due to inaccurate lateral translation of the collimator (35 Gy, 4 hours after irradiation). B) Accurate delivery of the microbeams. (350 Gy, 8 hours after irradiation).</p
    corecore