Construction and measurements of a vacuum-swing-adsorption radon-mitigation system
Long-lived alpha and beta emitters in the Rn decay chain on (and
near) detector surfaces may be the limiting background in many experiments
attempting to detect dark matter or neutrinoless double-beta decay, and in
screening detectors. In order to reduce backgrounds from radon-daughter
plate-out onto the wires of the BetaCage during its assembly, an
ultra-low-radon cleanroom is being commissioned at Syracuse University using a
vacuum-swing-adsorption radon-mitigation system. The radon filter shows
~20 reduction at its output, from 7.470.56 to 0.370.12
Bq/m, and the cleanroom radon activity meets project requirements, with a
lowest achieved value consistent with that of the filter, and levels
consistently < 2 Bq/m.Comment: 5 pages, 3 figures, Proceedings of Low Radioactivity Techniques (LRT)
2013, Gran Sasso, Italy, April 10-12, 201
3D simulations of vertical displacement events in tokamaks: A benchmark of M3D-C, NIMROD and JOREK
In recent years, the nonlinear 3D magnetohydrodynamic codes JOREK, M3D-C
and NIMROD developed the capability of modelling realistic 3D vertical
displacement events (VDEs) including resistive walls. In this paper, a
comprehensive 3D VDE benchmark is presented between these state of the art
codes. The simulated case is based on an experimental NSTX plasma but with a
simplified rectangular wall. In spite of pronounced differences between physics
models and numerical methods, the comparison shows very good agreement in the
relevant quantities used to characterize disruptions such as the 3D wall forces
and energy decay. This benchmark does not only bring confidence regarding the
use of the mentioned codes for disruption studies, but also shows differences
with respect to the used models (e.g. reduced versus full MHD models). The
simulations show important 3D features for a NSTX plasma such as the
self-consistent evolution of the halo current and the origin of the wall
forces. In contrast to other reduced MHD models based on an ordering in the
aspect ratio, the ansatz based JOREK reduced MHD model allows capturing the 3D
dynamics even in the spherical tokamak limit considered here
The acceleration and storage of radioactive ions for a neutrino factory
The term beta-beam has been coined for the production of a pure beam of
electron neutrinos or their antiparticles through the decay of radioactive ions
circulating in a storage ring. This concept requires radioactive ions to be
accelerated to a Lorentz gamma of 150 for 6He and 60 for 18Ne. The neutrino
source itself consists of a storage ring for this energy range, with long
straight sections in line with the experiment(s). Such a decay ring does not
exist at CERN today, nor does a high-intensity proton source for the production
of the radioactive ions. Nevertheless, the existing CERN accelerator
infrastructure could be used as this would still represent an important saving
for a beta-beam facility. This paper outlines the first study, while some of
the more speculative ideas will need further investigations.Comment: Accepted for publication in proceedings of Nufact02, London, 200
Axisymmetric simulations of vertical displacement events in tokamaks: A benchmark of M3D-C1, NIMROD and JOREK
A benchmark exercise for the modeling of vertical displacement events(VDEs) is presented and applied to the 3D nonlinear magneto-hydrodynamic codesM3D-C1, JOREK and NIMROD. The simulations are based on a vertically unstableNSTX equilibrium enclosed by an axisymmetric resistive wall with rectangular crosssection. A linear dependence of the linear VDE growth rates on the resistivity ofthe wall is recovered for sufficiently large wall conductivity and small temperatures inthe open field line region. The benchmark results show good agreement between theVDE growth rates obtained from linear NIMROD and M3D-C1simulations as wellas from the linear phase of axisymmetric nonlinear JOREK, NIMROD and M3D-C1simulations. Axisymmetric nonlinear simulations of a full VDE performed with thethree codes are compared and excellent agreement is found regarding plasma locationand plasma currents as well as eddy and halo currents in the wall.</p
Method for Efficiency and Time Response Measurement on Diverse Target Ion Sources with Stable Alkali
International audienceDevelopments of new setups for radioactive ion beam production by the isotope-separator-on-line (ISOL) method are underway at GANIL in the frame of the SPIRAL (Système de Production d'Ions Radioactifs Accélérés en Ligne) and SPIRAL-II projects. The measurement of total efficiency and time behaviour of these new target/ion-source systems (TISSs) is a crucial step for these devices which aims to produce short-lived isotopes with high intensity. The overall atom-to-ion transformation efficiency depends on several processes: diffusion of the atoms out of the production target, effusion towards the ion source and ionization. The efficiency can be extracted using the ratio between the emerging yield and implanted flux in the TISS. Several methods have already been developed to achieve these measurements: the use of stable or radioactive beams, gas injection, or the introduction of solid material into the TISS. This paper focuses primarily on a method that uses stable alkali. A pulsed/CW alkali ion gun has been built and will be used to optimise diverse TISSs
Recommended from our members
Numerical study of tilt stability of prolate field-reversed configurations
Global stability of the Field-Reversed Configuration (FRC) has been investigated numerically using both 3D MHD and hybrid (fluid electron and delta f particle ion) simulations. The stabilizing effects of velocity shear and large ion orbits on the n = 1 internal tilt mode in the prolate FRCs have been studied. Sheared rotation is found to reduce the growth rate, however a large rotation rate with Mach number of M greater than or approximately equal to 1 is required in order for significant reduction in the instability growth rate to occur. Kinetic effects associated with large thermal ion orbits have been studied for different kinetic equilibria. These simulations show that there is a reduction in the tilt mode growth rate due to finite ion Larmor radius (FLR) effects, but complete linear stability has not been found, even when the thermal ion gyroradius is comparable to the distance between the field null and the separatrix. The instability existing beyond the FLR theory threshold could be due to the resonant interaction of the wave with ions whose Doppler shifted frequency matches the betatron frequency
Recommended from our members
Numerical Study of Global Stability of Oblate Field-Reversed Configurations
Global stability of the oblate (small elongation, E < 1) Field-Reversed Configuration (FRC) has been investigated numerically using both three-dimensional magnetohydrodynamic (MHD) and hybrid (fluid electrons and kinetic ions) simulations. For every non-zero value of the toroidal mode number n, there are three MHD modes that must be stabilized. For n = 1, these are the interchange, the tilt and the radial shift; while for n > 1 these are the interchange and two co-interchange modes with different polarization. It is shown that the n = 1 tilt mode becomes an external mode when E < 1, and it can be effectively stabilized by close-fitting conducting shells, even in the small Larmor radii (MHD) regime. The tilt mode stability improves with increasing oblateness, however at suffciently small elongations the radial shift mode becomes more unstable than the tilt mode. The interchange mode stability is strongly profile dependent, and all n * 1 interchange modes can be stabilized for a class of pressure profile with separatrix beta larger than 0.035. Our results show that all three n = 1 modes can be stabilized in the MHD regime, but the stabilization of the n > 1 co-interchange modes still remains an open question
A 57-year-old man who developed arthritis during R-CHOP chemotherapy for non-Hodgkin lymphoma
Rituximab is a chimeric human-mouse anti-CD20 monoclonal antibody, which is used in the treatment of both B-cell lymphomas and rheumatic diseases. We describe a case of a previously healthy 57-year-old man developing arthritis while being treated with rituximab-CHOP chemotherapy (R-CHOP) for a non-Hodgkin lymphoma. The remittant arthritis developed at successively shorter time-intervals after R-CHOP administration and only improved after rituximab was removed from the chemotherapy schedule, suggesting a rituximab-related phenomenon, as extensive diagnostic testing ruled out any other diagnosis
Permanent magnets under irradiation and radiocative alkali ion beam development for SPIRAL1
International audienceUp to now, eighteen Target Ion Source Systems (TISSs) have been built and used for the production of radioactive ion beams on SPIRAL 1 facility, based on the Isotope- Separator-On-Line (ISOL) method. The TISSs are composed of thick carbon targets and of fully permanentmagnet Electron Cyclotron Resonance Ion Sources (ECRISs) of the Nanogan III type. After irradiation and a decay period of two years, the irradiated TISSs are dismounted and if their magnetic fields are still suitable, the ECRIS are used with a new target. Thereby thirty-two runs have been performed using new or renewed TISSs. , After irradiation, the measured magnetic field sometimes reveals magnet damage. Our experience is reported here. In the second section, we present the progress on the NanoNaKE setup, which aims to extend the radioactive ion beams in SPIRAL 1 to the alkali elements, by connecting a surface-ionization source to the Nanogan III ECRIS via a compact 1+ ion beam line. The main issues and difficulties are discussed and the preliminary solutions are described
MONOBOB II : Latest results of monocharged ions source for SPIRAL2 project
Original publication available at http://www.jacow.orgInternational audienceAmong the sources which can be installed in the radioactive ion production module of SPIRAL II, a singly-charged ECRIS has been chosen to produce ions from gaseous elements. Its characterization is under way on a test bench at GANIL. Extraction, transport and response time results are presented
- …