1,001 research outputs found

    Combined Diffusion-Relaxometry MRI to Identify Dysfunction in the Human Placenta

    Get PDF
    Purpose: A combined diffusion-relaxometry MR acquisition and analysis pipeline for in-vivo human placenta, which allows for exploration of coupling between T2* and apparent diffusion coefficient (ADC) measurements in a sub 10 minute scan time. Methods: We present a novel acquisition combining a diffusion prepared spin-echo with subsequent gradient echoes. The placentas of 17 pregnant women were scanned in-vivo, including both healthy controls and participants with various pregnancy complications. We estimate the joint T2*-ADC spectra using an inverse Laplace transform. Results: T2*-ADC spectra demonstrate clear quantitative separation between normal and dysfunctional placentas. Conclusions: Combined T2*-diffusivity MRI is promising for assessing fetal and maternal health during pregnancy. The T2*-ADC spectrum potentially provides additional information on tissue microstructure, compared to measuring these two contrasts separately. The presented method is immediately applicable to the study of other organs

    Complex diffusion-weighted image estimation via matrix recovery under general noise models

    Get PDF
    We propose a patch-based singular value shrinkage method for diffusion magnetic resonance image estimation targeted at low signal to noise ratio and accelerated acquisitions. It operates on the complex data resulting from a sensitivity encoding reconstruction, where asymptotically optimal signal recovery guarantees can be attained by modeling the noise propagation in the reconstruction and subsequently simulating or calculating the limit singular value spectrum. Simple strategies are presented to deal with phase inconsistencies and optimize patch construction. The pertinence of our contributions is quantitatively validated on synthetic data, an in vivo adult example, and challenging neonatal and fetal cohorts. Our methodology is compared with related approaches, which generally operate on magnitude-only data and use data-based noise level estimation and singular value truncation. Visual examples are provided to illustrate effectiveness in generating denoised and debiased diffusion estimates with well preserved spatial and diffusion detail.Comment: 26 pages, 9 figure

    Integrated and efficient diffusion-relaxometry using ZEBRA

    Get PDF
    The emergence of multiparametric diffusion models combining diffusion and relaxometry measurements provide powerful new ways to explore tissue microstructure with the potential to provide new insights into tissue structure and function. However, their ability to provide rich analyses and the potential for clinical translation critically depends on the availability of efficient, integrated, multi-dimensional acquisitions. We propose a fully integrated sequence simultaneously sampling the acquisition parameter spaces required for T1 and T2* relaxometry and diffusion MRI. Slice-level interleaved diffusion encoding, multiple spin/gradient echoes and slice-shuffling are combined for higher efficiency, sampling flexibility and enhanced internal consistency. In-vivo data was successfully acquired on healthy adult brains. Obtained parametric maps as well as clustering results demonstrate the potential of the technique regarding its ability to provide eloquent data with an acceleration of roughly 20 compared to conventionally used approaches. The proposed integrated acquisition, called ZEBRA, offers significant acceleration and flexibility compared to existing diffusion-relaxometry studies and thus facilitates wider use of these techniques both for research-driven and clinical applications

    Placental multimodal MRI prior to spontaneous preterm birth <32 weeks' gestation: An observational study

    Get PDF
    Objective: To utilise combined diffusion‐relaxation MRI techniques to interrogate antenatal changes in the placenta prior to extreme preterm birth among both women with PPROM and membranes intact, and compare this to a control group who subsequently delivered at term. Design: Observational study. Setting: Tertiary Obstetric Unit, London, UK. Population: Cases: pregnant women who subsequently spontaneously delivered a singleton pregnancy prior to 32 weeks' gestation without any other obstetric complications. Controls: pregnant women who delivered an uncomplicated pregnancy at term. Methods: All women consented to an MRI examination. A combined diffusion‐relaxation MRI of the placenta was undertaken and analysed using fractional anisotropy, a combined T2*‐apparent diffusion coefficient model and a combined T2*‐intravoxel incoherent motion model, in order to provide a detailed placental phenotype associated with preterm birth. Subgroup analyses based on whether women in the case group had PPROM or intact membranes at time of scan, and on latency to delivery were performed. Main Outcome Measures: Fractional anisotropy, apparent diffusion coefficients and T2* placental values, from two models including a combined T2*‐IVIM model separating fast‐ and slow‐flowing (perfusing and diffusing) compartments. Results: This study included 23 women who delivered preterm and 52 women who delivered at term. Placental T2* was lower in the T2*‐apparent diffusion coefficient model (p < 0.001) and in the fast‐ and slow‐flowing compartments (p = 0.001 and p < 0.001) of the T2*‐IVIM model. This reached a higher level of significance in the preterm prelabour rupture of the membranes group than in the membranes intact group. There was a reduced perfusion fraction among the cases with impending delivery. Conclusions: Placental diffusion‐relaxation reveals significant changes in the placenta prior to preterm birth with greater effect noted in cases of preterm prelabour rupture of the membranes. Application of this technique may allow clinically valuable interrogation of histopathological changes before preterm birth. In turn, this could facilitate more accurate antenatal prediction of preterm chorioamnionitis and so aid decisions around the safest time of delivery. Furthermore, this technique provides a research tool to improve understanding of the pathological mechanisms associated with preterm birth in vivo

    Optimisation of quantitative brain diffusion-relaxation MRI acquisition protocols with physics-informed machine learning

    Get PDF
    Diffusion-relaxation MRI aims to extract quantitative measures that characterise microstructural tissue properties such as orientation, size, and shape, but long acquisition times are typically required. This work proposes a physics-informed learning framework to extract an optimal subset of diffusion-relaxation MRI measurements for enabling shorter acquisition times, predict non-measured signals, and estimate quantitative parameters. In vivo and synthetic brain 5D-Diffusion- T 1 - T 2 ∗ -weighted MRI data obtained from five healthy subjects were used for training and validation, and from a sixth participant for testing. One fully data-driven and two physics-informed machine learning methods were implemented and compared to two manual selection procedures and Cramér-Rao lower bound optimisation. The physics-informed approaches could identify measurement-subsets that yielded more consistently accurate parameter estimates in simulations than other approaches, with similar signal prediction error. Five-fold shorter protocols yielded error distributions of estimated quantitative parameters with very small effect sizes compared to estimates from the full protocol. Selected subsets commonly included a denser sampling of the shortest and longest inversion time, lowest echo time, and high b-value. The proposed framework combining machine learning and MRI physics offers a promising approach to develop shorter imaging protocols without compromising the quality of parameter estimates and signal predictions

    Morphological and ecological convergence at the lower size limit for vertebrates highlighted by five new miniaturised microhylid frog species from three different Madagascan genera

    Get PDF
    Miniaturised frogs form a fascinating but poorly understood amphibian ecomorph and have been exceptionally prone to taxonomic underestimation. The subfamily Cophylinae (family Microhylidae), endemic to Madagascar, has a particularly large diversity of miniaturised species which have historically been attributed to the single genus Stumpffia largely based on their small size. Recent phylogenetic work has revealed that several independent lineages of cophyline microhylids evolved towards highly miniaturised body sizes, achieving adult snout- vent lengths under 16 mm. Here, we describe five new species belonging to three clades that independently miniaturised and that are all genetically highly divergent from their relatives: (i) a new genus (Mini gen.nov.) with three new species from southern Madagascar, (ii) one species of Rhombophryne, and (iii) one species of Anodonthyla. Mini mum sp. nov. from Manombo in eastern Madagascar is one of the smallest frogs in the world, reaching an adult body size of 9.7 mm in males and 11.3 mm in females. Mini scule sp.nov. from Sainte Luce in southeastern Madagascar is slightly larger and has maxillary teeth. Mini ature sp.nov. from Andohahela in southeast Madagascar is larger than its congeners but is similar in build. Rhombophryne proportionalis sp.nov. from Tsaratanana in northern Madagascar is unique among Madagascar's miniaturised frogs in being a proportional dwarf, exhibiting far less advanced signs of paedomorphism than other species of similar size. Anodonthyla eximia sp.nov. from Ranomafana in eastern Madagascar is distinctly smaller than any of its congeners and is secondarily terrestrial, providing evidence that miniaturisation and terrestriality may be evolutionarily linked. The evolution of body size in Madagascar's microhylids has been more dynamic than previously understood, and future studies will hopefully shed light on the interplay between ecology and evolution of these remarkably diverse frogs
    corecore